Exergetic efficiency optimization for an irreversible heat pump working on reversed Brayton cycle

This paper deals with the performance analysis and optimization for irreversible heat pumps working on reversed Brayton cycle with constant-temperature heat reservoirs by taking exergetic efficiency as the optimization objective combining exergy concept with finite-time thermodynamics (FTT). Exergetic efficiency is defined as the ratio of rate of exergy output to rate of exergy input of the system. The irreversibilities considered in the system include heat resistance losses in the hot- and cold-side heat exchangers and non-isentropic losses in the compression and expansion processes. The analytical formulas of the heating load, coefficient of performance (COP) and exergetic efficiency for the heat pumps are derived. The results are compared with those obtained for the traditional heating load and coefficient of performance objectives. The influences of the pressure ratio of the compressor, the allocation of heat exchanger inventory, the temperature ratio of two reservoirs, the effectiveness of the hot- and cold-side heat exchangers and regenerator, the efficiencies of the compressor and expander, the ratio of hot-side heat reservoir temperature to ambient temperature, the total heat exchanger inventory, and the heat capacity rate of the working fluid on the exergetic efficiency of the heat pumps are analysed by numerical calculations. The results show that the exergetic efficiency optimization is an important and effective criterion for the evaluation of an irreversible heat pump working on reversed Brayton cycle.

[1]  T. J. Kotas,et al.  The Exergy Method of Thermal Plant Analysis , 2012 .

[2]  Bjarne Andresen,et al.  Thermodynamics for Processes in Finite Time , 1984 .

[3]  Lingen Chen,et al.  Finite Time Thermodynamic Optimization or Entropy Generation Minimization of Energy Systems , 1999 .

[4]  S. C. Kaushik,et al.  Thermoeconomic optimization of an irreversible Stirling cryogenic refrigerator cycle , 2004 .

[5]  Fengrui Sun,et al.  Heating load, heating-load density and COP optimizations of an endoreversible air heat-pump , 2008 .

[6]  Yingru Zhao,et al.  Parametric optimum analysis of an irreversible Ericsson cryogenic refrigeration cycle working with an ideal Fermi gas , 2008 .

[7]  Cha'o-Kuang Chen,et al.  Exergetic efficiency optimization for an irreversible Brayton refrigeration cycle , 2005 .

[8]  D. C. Agrawal,et al.  Engines and refrigerators with finite heat reservoirs , 1990 .

[9]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[10]  Baris Sahin Exergy optimization for an endoreversible cogeneration cycle , 1997 .

[11]  S. Sieniutycz,et al.  Thermodynamic Optimization of Finite-Time Processes , 2000 .

[12]  Fengrui Sun,et al.  Performance analysis for endoreversible closed regenerated Brayton heat pump cycles , 1999 .

[13]  G. Angelino,et al.  Prospects for real-gas reversed Brayton cycle heat pumps , 1995 .

[14]  Fengrui Sun,et al.  Performance analysis of a closed regenerated Brayton heat pump with internal irreversibilities , 1999 .

[15]  Fengrui Sun,et al.  Optimization of steady flow heat pumps , 1998 .

[16]  Markku J. Lampinen,et al.  Thermodynamic analysis and optimization of the Brayton process in a heat recovery system of paper machines , 1993 .

[17]  Andrew C. Harvey,et al.  Research and development of an air-cycle heat-pump water heater , 1979 .

[18]  Cha'o-Kuang Chen,et al.  Exergy destruction minimization of an irreversible Carnot refrigeration cycle , 2007 .

[19]  Andrew G. Glen,et al.  APPL , 2001 .

[20]  Fernando Sisto The Reversed Brayton Cycle Heat Pump—A Natural Open Cycle for HVAC Applications , 1979 .

[21]  Shengwei Wang,et al.  Performance investigations under maximum ecological and maximum economic conditions of a complex Brayton cycle , 2007 .

[22]  Jahar Sarkar,et al.  Overall conductance and heat transfer area minimization of refrigerators and heat pumps with finite heat reservoirs , 2007 .

[23]  D. C. Agrawal,et al.  Finite‐time Carnot refrigerators with wall gain and product loads , 1993 .

[24]  S. C. Kaushik,et al.  Thermodynamic analysis and parametric study of an irreversible regenerative-intercooled-reheat Brayton cycle , 2006 .

[25]  Bahri Sahin,et al.  Optimization of thermal systems based on finite-time thermodynamics and thermoeconomics , 2004 .

[26]  T.Nejat Veziroǧlu,et al.  Hydrogen movement and the next action : Fossil fuels industry and sustainability economics , 1997 .

[27]  James E. Braun,et al.  Energy efficiency analysis of air cycle heat pump dryers , 2002 .

[28]  William M. Toscano,et al.  Research and development of an air-cycle heat-pump water heater. Final report , 1979 .

[29]  M. Cetron,et al.  Biodiesel production : a preliminary study from Jatropha Curcas , 2013 .

[30]  C-K Chen,et al.  Exergetic efficiency optimization of a refrigeration system with multi-irreversibilities , 2006 .

[31]  J. S. Fleming,et al.  Air cycle cooling and heating Part II: a mathematical model for the transient behaviour of fixed matrix regenerators , 1998 .

[32]  Michael J. Moran,et al.  Availability analysis: A guide to efficient energy use , 1982 .

[33]  Jim McGovern,et al.  Air cycle cooling and heating Part 1: a realistic appraisal and a chosen application , 1998 .

[34]  S. C. Kaushik,et al.  The performance characteristics of an irreversible regenerative intercooled Brayton cycle at maximum thermoeconomic function , 2005 .

[35]  S. C. Kaushik,et al.  A new thermoeconomic approach and parametric study of an irreversible regenerative Brayton refrigeration cycle , 2006 .

[36]  Fengrui Sun,et al.  Performance of Combined-Cycle Chemical Engines with Mass Leak , 1999 .