Control method for a combined active filter system employing a current source converter and a high pass filter
暂无分享,去创建一个
This paper describes a control method with a combined filter system which senses load current, source current and line voltage to create reference signals for an active filter. The transfer function of the active filter is identified and is used for the control system design. It is shown that the source current feedback is most effective to suppress the harmonic-enlarging effects due to parallel resonance and the harmonic current generated by source harmonic voltages. A small setup controlled by a DSP was built, and the validity of the proposed method was demonstrated by experimental results.<<ETX>>
[1] Hirofumi Akagi,et al. Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.
[2] S. Fukuda,et al. Design and characteristics of active power filter using current source converter , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.
[3] Toshifumi Ise,et al. Compensation characteristics and dynamics of the active filter for superconducting magnet energy storage , 1988 .