Modelling of natural convection in vertical and tilted photovoltaic applications

Abstract This investigation aims to examine and infer useful engineering information of the physical mechanisms which are found in applications of building-integrated photovoltaic (BIPV) systems for facades and roofs. Buoyancy-driven flow in heated open-ended channels was modelled with the channel inclination angle ranging from 15° to 90° and the channel height-to-width ratio being 20. In each case, a uniform heat flux was applied along the top wall and the bottom wall was assumed to be adiabatic. Effect of varying inclination angle on the velocity and temperature fields is explored through the mean and turbulence quantities. A comparison between experimental and modelling results shows that open-ended channels with low inclination angles are characterised by low chimney effect and induced flow rate, thereby decreasing the heat transfer along the photovoltaic panels. In addition, propagation of disturbances and vortical structures in the channel which are necessary to enhance heat transfer are less eminent in these cases. Furthermore, heat transfer characteristics of turbulent natural convection in tilted channels are recast in terms of relevant dimensionless parameters so that they may be readily applied in cases with the aspect ratio and heat fluxes which are considered in this study.

[1]  R. Viskanta,et al.  Experimental studies of combined heat transfer in turbulent mixed convection fluid flows in double-skin-façades , 2002 .

[2]  S. Fraser,et al.  Turbulent natural convection in a vertical parallel-plate channel with asymmetric heating , 2007 .

[3]  B. Gebhart,et al.  An experimental study of the transition of natural convection flow adjacent to a vertical surface , 1974 .

[4]  Christophe Menezo,et al.  NATURAL CONVECTION IN NONUNIFORMLY HEATED CHANNEL INVESTIGATIONAPPLICATION TO PHOTOVOLTAIC FACADES , 2009 .

[5]  Guan Heng Yeoh,et al.  Numerical investigation of passive cooling in open vertical channels , 2012 .

[6]  Christophe Menezo,et al.  Experimental natural convection on vertical surfaces for building integrated photovoltaic (BIPV) applications , 2008 .

[7]  Assensi Oliva,et al.  Natural Convection in a Large, Inclined Channel With Asymmetric Heating and Surface Radiation , 2003 .

[8]  H. Matsumoto,et al.  A laboratory experiment on natural ventilation through a roof cavity for reduction of solar heat gain , 2008 .

[9]  S. Burek,et al.  Air flow and thermal efficiency characteristics in solar chimneys and Trombe Walls , 2007 .

[10]  Ephraim M Sparrow,et al.  Observed Flow Reversals and Measured-Predicted Nusselt Numbers for Natural Convection in a One-Sided Heated Vertical Channel , 1984 .

[11]  B. W. Webb,et al.  High Rayleigh Number Laminar Natural Convection in an Asymmetrically Heated Vertical Channel , 1989 .

[12]  Mats Sandberg,et al.  Ventilated-solar roof air flow and heat transfer investigation , 1998 .

[13]  Ha Herbert Zondag,et al.  Flat-plate PV-Thermal collectors and systems : a review , 2008 .

[14]  Assaad Zoughaib,et al.  Modeling natural convection in a pitched thermosyphon system in building roofs and experimental validation using particle image velocimetry , 2010 .

[15]  Guan Heng Yeoh,et al.  Large-eddy simulation of natural convection in an asymmetrically-heated vertical parallel-plate channel: Assessment of subgrid-scale models , 2012 .

[16]  Guohui Gan Simulation of buoyancy-induced flow in open cavities for natural ventilation , 2006 .

[17]  Mats Sandberg,et al.  Buoyancy-induced air flow in photovoltaic facades: Effect of geometry of the air gap and location of solar cell modules , 2002 .

[18]  P. Moin,et al.  A dynamic subgrid‐scale model for compressible turbulence and scalar transport , 1991 .

[19]  Guan Heng Yeoh,et al.  Large-Eddy Simulation of Turbulent Natural Convection in Vertical Parallel-Plate Channels , 2011 .

[20]  P. Heiselberg,et al.  An Experimental Investigation of a Solar Chimney model with Uniform Wall Heat Flux , 2003 .

[21]  Andreas K. Athienitis,et al.  Convective Heat Transfer Coefficients in a Building-Integrated Photovoltaic/Thermal System , 2011 .

[22]  A. W. Vreman An eddy-viscosity subgrid-scale model for turbulent shear flow: Algebraic theory and applications , 2004 .

[23]  Hongxing Yang,et al.  Thermal behavior of a novel type see-through glazing system with integrated PV cells , 2009 .

[24]  B. Gebhart,et al.  Characteristic disturbance frequency in vertical natural convection flow , 1975 .

[25]  Ephraim M Sparrow,et al.  Natural Convection in Open-Ended Inclined Channels , 1985 .

[26]  A. Lahellec,et al.  Modelling natural convection in a heated vertical channel for room ventilation , 2000 .

[27]  Mohamed A. Habib,et al.  Turbulent natural convection between inclined isothermal plates , 2005 .

[28]  Siuming Lo,et al.  Flickering Behavior of Turbulent Buoyant Fires Using Large-Eddy Simulation , 2007 .

[29]  Hassan Bouia,et al.  Étude expérimentale des écoulements de convection naturelle en canal vertical différentiellement chauffé , 2011 .

[30]  Mats Sandberg,et al.  Flow and heat transfer in the air gap behind photovoltaic panels , 1998 .

[31]  U. Piomelli,et al.  Subgrid-Scale Models for Compressible Large-Eddy Simulations , 2000 .

[32]  Andreas K. Athienitis,et al.  Numerical and Experimental Study of Heat Transfer in a BIPV-Thermal System , 2007 .

[33]  J. J. Bloem,et al.  Evaluation of a PV-integrated building application in a well-controlled outdoor test environment , 2008 .