A three year long experience of effective fouling inhibition by threshold flux based optimization methods on a nf membrane module for olive mill wastewater treatment

The operation of a spiral-wounded nanofiltration membrane module used continuously for three years in order to purify different pretreated olive mill wastewater streams will be discussed. The membrane module was for the first time used at the beginning of year 2006 on a batch pilot scale plant for critical flux studies and wastewater treatment in our laboratories. The olive mill wastewater is a waste stream produced by the olive oil mill factories, characterized by very high organic matter load and polyphenols concentration. Without fouling inhibition at all, nanofiltration membranes will reach zero-flux conditions within days. This is not the case of this nanofiltration membrane module, which was successfully operated continuously for three years during our laboratory work. This result was reached by proper fouling inhibition control, relaying on both critical flux measurements and the development of an optimized operation method. Although the critical flux theory was successfully applied to this system, it was not capable to explain the observed fouling behavior of the examined membrane system. The doubt to work on a membrane system that does not follow perfectly the critical flux laws grow throughout the years. In year 2011, Field et al. introduced the threshold flux concept as an extension to particular membrane systems treating real wastewater streams, and this latter theory fits to the observations made on olive mill wastewater. In this work, a revision of previously obtained results in terms of critical flux will be performed, using the threshold flux theory as discussion basis. In the examined system, both critical and threshold points were found at 7-8 bar depending of the used feedstock and membrane condition. Moreover, it will be checked why the adopted "critical flux" approach was successful in inhibiting fouling for so many years despite it was not the correct approach.

[1]  Renbi Bai,et al.  MEMBRANE FOULING AND CLEANING IN MICROFILTRATION OF ACTIVATED SLUDGE WASTEWATER , 2003 .

[2]  Pierre Aimar,et al.  On an experimental method to measure critical flux in ultrafiltration , 2002 .

[3]  Marco Stoller,et al.  Reaction-precipitation by a spinning disc reactor: Influence of hydrodynamics on nanoparticles production , 2012 .

[4]  A. Fane,et al.  A fundamental study of the ultrafiltration of oil-water emulsions☆ , 1988 .

[5]  M. Bravi,et al.  Threshold flux measurements of a nanofiltration membrane module by critical flux data conversion , 2013 .

[6]  Pierre Le-Clech,et al.  Fouling in membrane bioreactors used in wastewater treatment , 2006 .

[7]  Mika Mänttäri,et al.  Critical flux in NF of high molar mass polysaccharides and effluents from the paper industry , 2000 .

[8]  M. Bravi,et al.  Critical flux analyses on differently pretreated olive vegetation waste water streams: Some case studies , 2010 .

[9]  R. Baker Membrane Technology and Applications , 1999 .

[10]  R. Field,et al.  Critical, sustainable and threshold fluxes for membrane filtration with water industry applications. , 2011, Advances in colloid and interface science.

[11]  A. Chianese,et al.  Photocatalytic Degradation of Organic Dyes under Visible Light onN-Doped Photocatalysts , 2012 .

[12]  Marco Stoller,et al.  Effective fouling inhibition by critical flux based optimization methods on a NF membrane module for olive mill wastewater treatment , 2011 .

[13]  A. Basile,et al.  Counter-current membrane reactor for WGS process: Membrane design , 2010 .

[14]  A. D. Marshall,et al.  Performance of crossflow microfiltration during constant transmembrane pressure and constant flux operations , 2002 .

[15]  R. Field,et al.  Critical flux concept for microfiltration fouling , 1995 .

[16]  Marco Stoller,et al.  Optimization of membrane batch processes by means of the critical flux theory , 2006 .

[17]  Robert Langer,et al.  High-throughput membrane surface modification to control NOM fouling. , 2009, Environmental science & technology.

[18]  M. Stoller On the effect of flocculation as pretreatment process and particle size distribution for membrane fouling reduction , 2009 .

[19]  C. Merli,et al.  Optimization of a nanofiltration membrane process for tomato industry wastewater effluent treatment , 2009 .

[20]  A. Chianese,et al.  Influence of the adopted pretreatment process on the critical flux value of batch membrane processes , 2007 .

[21]  Marco Stoller,et al.  Technical optimization of a dual ultrafiltration and nanofiltration pilot plant in batch operation by means of the critical flux theory: A case study , 2008 .

[22]  A. Chianese,et al.  Technical optimization of a batch olive wash wastewater treatment membrane plant , 2006 .

[23]  M. Bravi,et al.  Batch membrane treatment of olive vegetation wastewater from two-phase olive oil production process by threshold flux based methods , 2012 .

[24]  M. Velarde Advances in Colloid and Interface Science , 2014 .

[25]  Robert W. Field,et al.  Critical and sustainable fluxes: Theory, experiments and applications , 2006 .