Usability Analysis and Redesign of Infusion Pump User Interface

Infusion pump is a vital medical device used to continually deliver medications or fluids to the patient's body in a controlled manner. This device is capable of delivering predetermined amounts of fluids and may be used to deliver nutrients, blood, or medications, such as antibiotics, pain medications, and chemotherapeutic. However, due to poorly designed user interface, misuses can be prevalent and might lead to serious medical errors, such as dosing errors. The aim of this research is to (1) identify usability problems of infusion pumps commonly used in oncology clinics and other outpatient settings through interviews and heuristic evaluation; (2) propose new designs to address the problems and eventually improve performance. During a heuristic evaluation, three major violations of human factors design principles were identified: (1) lack of feedback about the patient and the patient condition? Not sure if this is a violation; (2) poor flexibility and efficiency of use; (3) the position of start/stop button can limit the control over the task. We proposed a new interface design to overcome these issues.

[1]  Sallie J. Weaver,et al.  Making health care safer II: an updated critical analysis of the evidence for patient safety practices. , 2013, Evidence report/technology assessment.

[2]  Jakob Nielsen,et al.  Usability engineering , 1997, The Computer Science and Engineering Handbook.

[3]  Jonathan Histon,et al.  A User-Centered Evaluation of three Intravenous Infusion Pumps , 2004 .

[4]  Jan Maarten Schraagen,et al.  Methods for studying medical device technology and practitioner cognition: the case of user-interface issues with infusion pumps. , 2013, Journal of biomedical informatics.

[5]  R. Scott Evans,et al.  Enhanced Notification of Infusion Pump Programming Errors , 2010, MedInfo.

[6]  Christopher D. Wickens,et al.  An introduction to human factors engineering , 1997 .

[7]  Jared Freeman,et al.  UPDATE: A Usability Analysis Method and Tool , 2007 .

[8]  Allison Lamsdale,et al.  A Usability Evaluation of an Infusion Pump by Nurses Using a Patient Simulator , 2005 .

[9]  Patricia C. Dykes,et al.  Evaluation of Intravenous Medication Errors with Smart Infusion Pumps in an Academic Medical Center , 2013, AMIA.

[10]  P. Maurette [To err is human: building a safer health system]. , 2002, Annales francaises d'anesthesie et de reanimation.

[11]  Vimla L. Patel,et al.  Using usability heuristics to evaluate patient safety of medical devices , 2003, J. Biomed. Informatics.

[12]  Ben Shneiderman,et al.  Designing The User Interface , 2013 .

[13]  Stephen Keay,et al.  The safe use of infusion devices , 2004 .

[14]  Vimla L. Patel,et al.  Heuristic evaluation of infusion pumps: implications for patient safety in Intensive Care Units , 2004, Int. J. Medical Informatics.