Telecentric 3D profilometry based on phase-shifting fringe projection.

Three dimensional shape measurement in the microscopic range becomes increasingly important with the development of micro manufacturing technology. Microscopic fringe projection techniques offer a fast, robust, and full-field measurement for field sizes from approximately 1 mm2 to several cm2. However, the depth of field is very small due to the imaging of non-telecentric microscope, which is often not sufficient to measure the complete depth of a 3D-object. And the calibration of phase-to-depth conversion is complicated which need a precision translation stage and a reference plane. In this paper, we propose a novel telecentric phase-shifting projected fringe profilometry for small and thick objects. Telecentric imaging extends the depth of field approximately to millimeter order, which is much larger than that of microscopy. To avoid the complicated phase-to-depth conversion in microscopic fringe projection, we develop a new system calibration method of camera and projector based on telecentric imaging model. Based on these, a 3D reconstruction of telecentric imaging is presented with stereovision aided by fringe phase maps. Experiments demonstrated the feasibility and high measurement accuracy of the proposed system for thick object.

[1]  Song Zhang,et al.  High dynamic range scanning technique , 2009 .

[2]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[3]  Zhong Chen,et al.  Telecentric stereo micro-vision system: Calibration method and experiments , 2014 .

[4]  Sai Siva Gorthi,et al.  Fringe projection techniques: Whither we are? , 2010 .

[5]  Du-Ming Tsai,et al.  A fast full-field 3D measurement system for BGA coplanarity inspection , 2003 .

[6]  K. Reichard,et al.  Calibration-based phase-shifting projected fringe profilometry for accurate absolute 3D surface profile measurement , 2003 .

[7]  Peisen Huang,et al.  Microscopic phase-shifting profilometry based on digital micromirror device technology. , 2002, Applied optics.

[8]  Du-Ming Tsai,et al.  Full-Field 3-D Flip-Chip Solder Bumps Measurement Using DLP-Based Phase Shifting Technique , 2008, IEEE Transactions on Advanced Packaging.

[9]  Eduard Reithmeier,et al.  Accurate calibration of a fringe projection system by considering telecentricity , 2011, Optical Metrology.

[10]  S. Ri,et al.  Fast and accurate shape measurement system utilizing the fringe projection method with a ferroelectric liquid-crystal-on-silicon microdisplay , 2012 .

[11]  Takeo Kanade,et al.  Multiaperture telecentric lens for 3D reconstruction. , 2011, Optics letters.

[12]  Song Zhang Recent progresses on real-time 3D shape measurement using digital fringe projection techniques , 2010 .

[13]  J. M. Huntley,et al.  Temporal phase-unwrapping algorithm for automated interferogram analysis. , 1993, Applied optics.

[14]  Peisen S. Huang,et al.  Novel method for structured light system calibration , 2006 .

[15]  Mumin Song,et al.  Overview of three-dimensional shape measurement using optical methods , 2000 .

[16]  Hongjian Shi,et al.  Accurate 3D measurement system and calibration for speckle projection method , 2010 .

[17]  H J Tiziani,et al.  Application of a liquid-crystal spatial light modulator for brightness adaptation in microscopic topometry. , 2000, Applied optics.

[18]  Dong Li,et al.  An accurate calibration method for a camera with telecentric lenses , 2013 .

[19]  Klaus-Peter Proll,et al.  Microscopic three-dimensional topometry with ferroelectric liquid-crystal-on-silicon displays. , 2003, Applied optics.