Digital breast tomosynthesis using an amorphous selenium flat panel detector

A prototype breast tomosynthesis system has been developed, allowing a total angular view of ±25°. The detector used in this system is an amorphous selenium direct-conversion digital flat-panel detector suitable for digital tomosynthesis. The system is equipped with various readout sequences to allow the investigation of different tomosynthetic data acquisition modes. In this paper, we will present basic physical properties -- such as MTF, NPS, and DQE -- measured for the full resolution mode and a binned readout mode of the detector. From the measured projections, slices are reconstructed employing a special version of filtered backprojection algorithm. In a phantom study, we compare binned and full resolution acquisition modes with respect to image quality. Under the condition of same dose, we investigate the impact of the number of views on artifacts. Finally, we show tomosynthesis images reconstructed from first clinical data.

[1]  Vincent Loustauneau,et al.  Ghosting comparison for large-area selenium detectors suitable for mammography and general radiography , 2004, SPIE Medical Imaging.

[2]  Per Skaane,et al.  Screen-film mammography versus full-field digital mammography with soft-copy reading: randomized trial in a population-based screening program--the Oslo II Study. , 2004, Radiology.

[3]  C J D'Orsi,et al.  Comparison of tomosynthesis methods used with digital mammography. , 2000, Academic radiology.

[4]  Benno Heigl,et al.  Improving 3D image quality of x-ray C-arm imaging systems by using properly designed pose determination systems for calibrating the projection geometry , 2003, SPIE Medical Imaging.

[5]  C J D'Orsi,et al.  Evaluation of linear and nonlinear tomosynthetic reconstruction methods in digital mammography. , 2001, Academic radiology.

[6]  C. D'Orsi,et al.  Clinical comparison of full-field digital mammography and screen-film mammography for detection of breast cancer. , 2002, AJR. American journal of roentgenology.

[7]  D. Kopans,et al.  Tomographic mammography using a limited number of low-dose cone-beam projection images. , 2003, Medical physics.

[8]  Günter Lauritsch,et al.  Theoretical framework for filtered back projection in tomosynthesis , 1998, Medical Imaging.

[9]  N. Navab,et al.  Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional procedures , 2000, IEEE Transactions on Medical Imaging.

[10]  D. Kopans,et al.  Digital tomosynthesis in breast imaging. , 1997, Radiology.

[11]  Tao Wu,et al.  A comparison of reconstruction algorithms for breast tomosynthesis. , 2004, Medical physics.

[12]  Kunio Doi,et al.  A simple method for determining the modulation transfer function in digital radiography , 1992, IEEE Trans. Medical Imaging.

[13]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.

[14]  D. G. Grant Tomosynthesis: a three-dimensional radiographic imaging technique. , 1972, IEEE transactions on bio-medical engineering.

[15]  John M. Boone Spectral modeling and compilation of quantum fluence in radiography and mammography , 1998, Medical Imaging.