Scintillation light emission studies of LSO scintillators

UV and /spl gamma/-ray excited luminescence and nuclear spectroscopy were used to study the relationship between the scintillation mechanisms of LSO and the spectroscopic characteristics obtained with PMT and APD readouts at room temperature. No correlation was found between scintillation decay time and light output. Like other investigators, we observed the existence of two distinct luminescence centers, Ce1 and Ce2, that mainly give rise to short (420 nm) and long (440 nm) emission wavelengths. Our measurements showed that different LSO crystals excited by /spl gamma/-rays have emission spectra with largely different shapes and maxima depending on the relative population and luminescence efficiency of these centers. It was also found that the poor energy resolution of LSO and YSO scintillators is well correlated with the coexistence of the two competing luminescence mechanisms. The prevalence of either Ce1 or Ce2 luminescence tends to reduce the variance of light emission and, thus, to improve energy resolution. Inversely, the coexistence of the two centers increases variance and degrades energy resolution.

[1]  Roger Lecomte,et al.  Investigation of GSO, LSO and YSO scintillators using reverse avalanche photodiodes , 1997 .

[2]  Magnus Dahlbom,et al.  Investigation of LSO crystals for high spatial resolution positron emission tomography , 1996 .

[3]  P. Dorenbos,et al.  Non-proportionality in the scintillation response and the energy resolution obtainable with scintill , 1995 .

[4]  W. Moses,et al.  A room temperature LSO/PIN photodiode PET detector module that measures depth of interaction , 1995 .

[5]  D. Wolski,et al.  Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers , 1998 .

[6]  Bernd J. Pichler,et al.  Studies with a prototype high resolution PET scanner based on LSO-APD modules , 1997 .

[7]  H. Suzuki,et al.  Light emission mechanism of Lu/sub 2/(SiO/sub 4/)O:Ce , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[8]  C. D’Ambrosio,et al.  On the scintillation response of NaI(TI)-crystals , 1997 .

[9]  Roger Lecomte,et al.  Radiation detection measurements with a new “Buried Junction” silicon avalanche photodiode , 1999 .

[10]  Non-linear Response In The Scintillation Yield Of Lu/sub 2/ SiO/sub 5/ O:Ce/sup 3+/ , 1993 .

[11]  R. Nutt,et al.  Investigation of depth-of-interaction by pulse shape discrimination in multicrystal detectors read out by avalanche photodiodes , 1998 .

[12]  Charles L. Melcher,et al.  UV and gamma-ray excited luminescence of cerium-doped rare earth oxyorthosilicates , 1992 .

[13]  W. W. Moses,et al.  Gamma ray spectroscopy and timing using LSO and PIN photodiodes , 1995 .

[14]  J. D. Valentine,et al.  The light yield nonproportionality component of scintillator energy resolution , 1997, IEEE Nuclear Science Symposium Conference Record.

[15]  Charles L. Melcher,et al.  Light emission mechanism of Lu/sub 2/(SiO/sub 4/)O:Ce , 1992 .

[16]  Michael V. Green,et al.  Depth identification accuracy of a three layer phoswich PET detector module , 1999 .

[17]  R. Mcintyre,et al.  A short-wavelength selective reach-through avalanche photodiode , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[18]  Magnus Dahlbom,et al.  Performance of a YSO/LSO phoswich detector for use in a PET/SPECT system , 1997 .

[19]  Craig S. Levin,et al.  Investigation of a new readout scheme for high resolution scintillation crystal arrays using photodiodes , 1997 .