Axial hydrodynamic studies in a gas–liquid–solid circulating fluidized bed riser

Abstract Axial distribution of phase holdups was studied in the riser of a gas–liquid–solid circulating fluidized bed (GLSCFB). The effects of gas and liquid superficial velocities as well as solids circulation rate on radial distribution of phase holdups at different axial locations were investigated. Electrical resistance tomography (ERT) and optical fiber probe were employed online in the experiments for a precise determination of phase holdups. An empirical model was developed for the determination of gas bubbles in analysis of data obtained by fiber optic sensor. Gas holdup was higher at the central region of the riser and increased axially due to coalescence of small bubbles and decrease of hydrostatic pressure at higher levels in the riser. This led to an increase in solids holdup in regions close to the wall which was slightly higher than the solids holdup at the wall. Both solids and liquid holdups were lower in the central region and increased radially towards the wall. Gas holdup decreased with increasing solids circulation rate but opposite trend was observed for solids holdup. Solids circulation rate had negligible effect on liquid holdup at lower axial locations compared to top of the riser. Cross-sectional average of solids, gas and liquid holdups did not change significantly at higher liquid superficial velocities.

[1]  Zhu Yu,et al.  Flow regimes of the three‐phase circulating fluidized bed , 1995 .

[2]  A. Margaritis,et al.  Continuous protein recovery from whey using liquid-solid circulating fluidized bed ion-exchange extraction. , 2002, Biotechnology and bioengineering.

[3]  Jinfu Wang,et al.  EXPERIMENTAL STUDY ON GAS-HOLDUP AND GAS-LIQUID INTERFACIAL AREA IN TPCFBs , 2001 .

[4]  G. Nakhla,et al.  Detachment of multi species biofilm in circulating fluidized bed bioreactor. , 2005, Biotechnology and bioengineering.

[5]  Jesse Zhu,et al.  Simultaneous carbon, nitrogen and phosphorous removal from municipal wastewater in a circulating fluidized bed bioreactor. , 2006, Chemosphere.

[6]  Shahzad Barghi,et al.  Electrical resistance tomography for flow characterization of a gas–liquid–solid three-phase circulating fluidized bed , 2007 .

[7]  G. Nakhla,et al.  Parametric study of the factors influencing simultaneous denitrification and enhanced biological phosphorus removal , 2006 .

[8]  A. Margaritis,et al.  Continuous protein recovery with a liquid–solid circulating fluidized‐bed ion exchanger , 2002 .

[9]  Liang-Shih Fan,et al.  ECT imaging of three-phase fluidized bed based on three-phase capacitance model , 2003 .

[10]  Ying Zheng,et al.  Flow Characterization of a Three‐Phase Circulating Fluidized Bed Using an Ultrasonic Technique , 2008 .

[11]  Maurice A. Bergougnou,et al.  Bubble measurement in three-phase fluidized beds using a u-shaped optical fiber , 1984 .

[12]  Shahzad Barghi,et al.  Phase holdup measurement in a gas–liquid–solid circulating fluidized bed (GLSCFB) riser using electrical resistance tomography and optical fibre probe , 2009 .

[13]  Shigeo Uchida,et al.  Measurement of longitudinal distribution of solids holdup in a three‐phase fluidized bed by ultrasonic technique , 1989 .

[14]  Shahzad Barghi,et al.  Radial Distributions of Phase Holdups and Phase Propagation Velocities in a Three-Phase Gas−Liquid−Solid Fluidized Bed (GLSCFB) Riser , 2009 .

[15]  D. L. George,et al.  Three-phase material distribution measurements in a vertical flow using gamma-densitometry tomography and electrical-impedance tomography , 2001 .

[16]  Ying Zheng,et al.  (Gas‐)liquid‐solid circulating fluidized beds and their potential applications to bioreactor engineering , 2000 .

[17]  H. de Lasa,et al.  Phase holdups in three‐phase fluidized beds , 1987 .