Image Reconstruction in Electrical Impedance Tomography (EIT) with Projection Error Propagation-based Regularization (PEPR): A Practical Phantom Study

Resistivity reconstruction of practical phantoms is studied with Projection Error Propagation-based Regularization (PEPR) method to improve the image quality in Electrical Impedance Tomography (EIT). PEPR method calculates the regularization parameter as a function of the projection error produced due to the mismatch between experimental measurements and the calculated data. The regularization parameter in the reconstruction algorithm automatically adjusts its magnitude depending on the noise level present in measured data as well as the ill-posedness of the Hessian matrix. Resistivity images are reconstructed from the practical phantom data using the Electrical Impedance Diffuse Optical Reconstruction Software (EIDORS). The resistivity images reconstructed with PEPR method are compared with the Single step Tikhonov Regularization (STR) and Modified Levenberg Regularization (LMR) techniques. The results show that, the PEPR technique reduces the reconstruction errors in each iteration and improves the reconstructed images with better contrast to noise ratio (CNR), percentage of contrast recovery (PCR), coefficient of contrast (COC) and diametric resistivity profile (DRP).

[1]  Philippe Renaud,et al.  Cell Culture Imaging Using Microimpedance Tomography , 2008, IEEE Transactions on Biomedical Engineering.

[2]  K D Paulsen,et al.  Contrast-detail analysis for detection and characterization with near-infrared diffuse tomography. , 2000, Medical physics.

[3]  David S. Holder,et al.  Electrical Impedance Tomography : Methods, History and Applications , 2004 .

[4]  R H Bayford,et al.  Bioimpedance tomography (electrical impedance tomography). , 2006, Annual review of biomedical engineering.

[5]  D S Holder,et al.  Some practical biological phantoms for calibrating multifrequency electrical impedance tomography. , 1996, Physiological measurement.

[6]  W. Hou,et al.  New regularization method in electrical impedance tomography , 2002 .

[7]  M. Hanke A regularizing Levenberg - Marquardt scheme, with applications to inverse groundwater filtration problems , 1997 .

[8]  Chris Chatwin,et al.  A flexible low-cost, high-precision, single interface electrical impedance tomography system for breast cancer detection using FPGA , 2010, Journal of Physics: Conference Series.

[9]  Jari P. Kaipio,et al.  Tikhonov regularization and prior information in electrical impedance tomography , 1998, IEEE Transactions on Medical Imaging.

[10]  Tushar Kanti Bera,et al.  Resistivity imaging of a reconfigurable phantom with circular inhomogeneities in 2D-electrical impedance tomography , 2011 .

[11]  David Isaacson,et al.  Electrical Impedance Tomography , 1999, SIAM Rev..

[12]  Qing Wu,et al.  A novel combination method of electrical impedance tomography inverse problem for brain imaging , 2005 .

[13]  Y. L. Mo,et al.  Increasing image resolution in electrical impedance tomography , 2002 .

[14]  C. L. Philip Chen,et al.  Regularization parameter estimation for feedforward neural networks , 2003 .

[15]  T. Bera,et al.  Studying the Elemental Resistivity Profile of Electrical Impedance Tomography (EIT) Images to Assess the Reconstructed Image Quality , 2011 .

[16]  Mi Wang,et al.  Electrical resistance tomography for process applications , 1996 .

[17]  Liliana Borcea,et al.  Electrical impedance tomography , 2002 .

[18]  Tushar Kanti Bera,et al.  A study of practical biological phantoms with simple instrumentation for Electrical Impedance Tomography (EIT) , 2009, 2009 IEEE Instrumentation and Measurement Technology Conference.

[19]  Richard H. Bayford,et al.  Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method , 2003, NeuroImage.

[20]  Brian H. Brown,et al.  Medical impedance tomography and process impedance tomography: a brief review , 2001 .

[21]  Tushar Kanti Bera,et al.  A Simple instrumentation calibration technique for Electrical Impedance Tomography (EIT) using a 16-electrode phantom , 2009, 2009 IEEE International Conference on Automation Science and Engineering.

[22]  Denyer Cwl Electronics for real-time and three-dimensional electrical impedance tomographs. , 1996 .

[23]  L M Heikkinen,et al.  A MATLAB package for the EIDORS project to reconstruct two-dimensional EIT images. , 2001, Physiological measurement.

[24]  K. R. Venugopal,et al.  Computer Networks and Intelligent Computing , 2011 .

[25]  Tianzi Jiang,et al.  Improving image quality of diffuse optical tomography with a projection-error-based adaptive regularization method. , 2008, Optics express.

[26]  Tushar Kanti Bera,et al.  Improving Image Quality in Electrical Impedance Tomography (EIT) Using Projection Error Propagation-Based Regularization (PEPR) Technique: A Simulation Study , 2011 .

[27]  David S. Holder,et al.  Clinical and physiological applications of electrical impedance tomography , 1993 .

[28]  Tushar Kanti Bera,et al.  A FEM-Based Forward Solver for Studying the Forward Problem of Electrical Impedance Tomography (EIT) with A Practical Biological Phantom , 2009, 2009 IEEE International Advance Computing Conference.