Condition Assessment of I&C Cables in Nuclear Power Plants via Stepped-Frequency Waveform Reflectometry

A nuclear power plant (NPP) depends on instrumentation and control (I&C) systems to ensure its safe and efficient operation. In particular, I&C cables take on the pivotal role of measuring and controlling the critical equipment of the NPP. Thus, it is indubitable that the diagnostic technology of I&C cables for detecting faults and accurately assessing their health status is required for ensuring the safety and reliability of the NPP operation. We propose a diagnostic method that combines fault detection and evaluation algorithm for the I&C cables with stepped-frequency waveform reflectometry with signal propagation and reflection modeling. The signal modeling allows the assessment of the fault with an estimated reflection coefficient by separating the propagation and reflection effects of the measured signal. In short, cable faults are differentiated and quantified regardless of distance. The proposed algorithm is verified by characteristic impedance measurement, various fault detection/evaluation experiments, and the fault evaluation of local accelerated thermal aging cable.

[1]  Kok Leong Mun Stepped frequency imaging radar simulation , 2000 .

[2]  K. Gillen,et al.  Investigation of Cable Deterioration Inside Reactor Containment , 1982 .

[3]  H. M. Hashemian,et al.  Cable condition monitoring for nuclear power plants , 2012, 2012 Future of Instrumentation International Workshop (FIIW) Proceedings.

[4]  Leon Cohen,et al.  Pulse propagation in dispersive media , 2000, Proceedings of the Tenth IEEE Workshop on Statistical Signal and Array Processing (Cat. No.00TH8496).

[5]  T. Okamoto,et al.  Mechanical aging trend in ethylene propylene rubber-insulated safety cables sampled from bwr nuclear power containment , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  R. King Electromagnetic waves and antennas above and below the surface of the earth , 1979 .

[7]  Y. S. Hung,et al.  Signature representation of underground cables and its applications to cable fault diagnosis , 1993 .

[8]  Hashem M. Hashemian,et al.  State-of-the-Art Predictive Maintenance Techniques* , 2011, IEEE Transactions on Instrumentation and Measurement.

[9]  C. Furse,et al.  Analysis of spread spectrum time domain reflectometry for wire fault location , 2005, IEEE Sensors Journal.

[10]  Olfa Kanoun,et al.  A New Algorithm for Wire Fault Location Using Time-Domain Reflectometry , 2014, IEEE Sensors Journal.

[11]  S. Burnay An overview of polymer ageing studies in the nuclear power industry , 2001 .

[12]  Jin Bae Park,et al.  Condition Monitoring of Instrumentation Cable Splices Using Kalman Filtering , 2015, IEEE Transactions on Instrumentation and Measurement.

[13]  Cam Nguyen,et al.  Stepped-Frequency Radar Sensors : Theory, Analysis and Design , 2016 .

[14]  K. Chang-Liao,et al.  Monitoring the moisture-related degradation of ethylene propylene rubber cable by electrical and SEM methods , 2006 .

[15]  Fabrice M. Guerout,et al.  Development of indentation techniques in support of cable condition monitoring programs , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[16]  Jin Bae Park,et al.  Application of time-frequency domain reflectometry for detection and localization of a fault on a coaxial cable , 2005, IEEE Transactions on Instrumentation and Measurement.

[17]  Sailes K. Sengijpta Fundamentals of Statistical Signal Processing: Estimation Theory , 1995 .

[18]  Leon Cohen,et al.  A Wigner approximation method for wave propagation , 2005 .

[19]  Jian Li,et al.  Amplitude estimation of sinusoidal signals: survey, new results, and an application , 2000, IEEE Trans. Signal Process..

[20]  D. Wehner High Resolution Radar , 1987 .

[21]  W. Z. Ibrahim Assessment of Signals Reliability for Instrumentation and Control System for Nuclear Power Plants , 2015 .

[22]  K. Anandakumaran,et al.  Aging and condition monitoring studies of composite insulation cables used in nuclear power plants , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[23]  Ali Yener Mutlu,et al.  A Time-Frequency-Based Approach to Phase and Phase Synchrony Estimation , 2011, IEEE Transactions on Signal Processing.

[24]  Cynthia Furse,et al.  Frequency-domain reflectometry for on-board testing of aging aircraft wiring , 2003 .

[25]  Gary Harmon,et al.  Methods for testing nuclear power plant cables , 2013, IEEE Instrumentation & Measurement Magazine.

[26]  Richard A. Guinee A novel transmission line test and fault location methodology using pseudorandom binary sequences , 2008 .

[27]  T. Seguchi,et al.  Degradation of cable insulation material by accelerated thermal radiation combined ageing , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.