A Comparison of the LigaSure and Harmonic Scalpel in Thyroid Surgery: A Single Institution Review

BackgroundDuring the last few years, many surgeons have begun to utilize the LigaSure device or Harmonic scalpel to perform thyroid surgery. Several papers have demonstrated the benefits of these devices compared with traditional hand-tying techniques. The purpose of this study was to examine our institution’s experience with the LigaSure device and Harmonic scalpel during thyroid surgery and to compare mean operative times and complications associated with each device.MethodsA retrospective chart review was performed on all patients who underwent thyroid surgery using the LigaSure device or Harmonic scalpel at a single institution between December 2005 and August 2009. Charts were reviewed for patient demographics, mean operative time, length of stay, and complications, such as transient recurrent laryngeal nerve injury, hypocalcemia, and hematoma formation.ResultsA total of 231 patients were included in the study, of whom 123 underwent total thyroidectomy and 108 underwent lobectomy. There was a significant decrease in the operative time for both thyroidectomies and lobectomies when the Harmonic scalpel was utilized. In regard to complications, there was no statistically significant difference in the number of transient and permanent recurrent laryngeal nerve injuries, percentage of patients developing hypocalcemia, or rate of hematoma development.ConclusionIn this study, there was no difference in the rate of complications between the two devices. However, the use of the Harmonic scalpel significantly decreased operative time for both thyroidectomies and thyroid lobectomies compared with the LigaSure device.

[1]  G. Sleilaty,et al.  Morbidity and mortality of thyroidectomy for substernal goiter , 2009, Head & neck.

[2]  M. K. Li,et al.  A Double-Blind, Randomized Trial Comparing LigasureTM and Harmonic ScalpelTM Hemorrhoidectomy , 2005 .

[3]  L. Sandonato,et al.  La coagulazione elettrotermica bipolare (ligasure bipolar vessel sealing system) in chirurgia della tiroide , 2003 .

[4]  M. K. Li,et al.  A double-blind, randomized trial comparing Ligasure and Harmonic Scalpel hemorrhoidectomy. , 2005, Diseases of the colon and rectum.

[5]  E. Choi,et al.  Clipless and sutureless endoscopic thyroidectomy using only the harmonic scalpel , 2010, Surgical Endoscopy.

[6]  M. Helal,et al.  Laparoscopic nephrectomy using the harmonic scalpel. , 1997, Journal of endourology.

[7]  E. Prokopakis,et al.  The use of Ligasure Vessel Sealing System in thyroid surgery , 2005, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[8]  E. Berber,et al.  The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery. , 2002, Archives of surgery.

[9]  S. Agle,et al.  A Comparison of Two Methods of Hemostasis in Thyroidectomy , 2009, The American surgeon.

[10]  J. Gauthier,et al.  Comparison of Ligasure Vessel Sealing System, Harmonic Scalpel, and Conventional Hemostasis in Total Thyroidectomy , 2009, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[11]  F. Romano,et al.  Laparoscopic splenectomy using ligasure , 2002, Surgical Endoscopy.

[12]  M. Robbins,et al.  Laparoscopic-assisted vaginal hysterectomy using the laparosonic coagulating shears. , 1995, The Journal of the American Association of Gynecologic Laparoscopists.

[13]  P. Parrilla,et al.  Prospective Study of Postoperative Complications After Total Thyroidectomy for Multinodular Goiters by Surgeons With Experience in Endocrine Surgery , 2004, Annals of surgery.

[14]  Herb Chen,et al.  The use of the Ligasure for hemostasis during thyroid lobectomy. , 2008, American journal of surgery.

[15]  J. Dubuc-Lissoir Use of a new energy-based vessel ligation device during laparoscopic gynecologic oncologic surgery , 2003, Surgical Endoscopy And Other Interventional Techniques.

[16]  M. Latteri,et al.  [Bipolar electrothermic coagulation (ligasure bipolar vessel sealing system) in thyroid surgery]. , 2003, Chirurgia italiana.

[17]  A. Giddings,et al.  The history of thyroidectomy , 1998, Journal of the Royal Society of Medicine.

[18]  F. Romano,et al.  Laparoscopic splenectomy using Ligasure. Preliminary experience. , 2002, Surgical Endoscopy.

[19]  L. Shemen Thyroidectomy using the Harmonic Scalpel: Analysis of 105 Consecutive Cases , 2002, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[20]  K. Hamid,et al.  Outpatient thyroidectomy is safe and reasonable: experience with more than 1,000 planned outpatient procedures. , 2010, Journal of the American College of Surgeons.

[21]  M. Guerrieri,et al.  Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study , 2007, Surgical Endoscopy.

[22]  E. Targarona,et al.  Energy Sources for Laparoscopic Colectomy: A Prospective Randomized Comparison of Conventional Electrosurgery, Bipolar Computer-Controlled Electrosurgery and Ultrasonic Dissection. Operative Outcome and Costs Analysis , 2005, Surgical innovation.

[23]  Herb Chen,et al.  Preserving function and quality of life after thyroid and parathyroid surgery. , 2008, The Lancet. Oncology.