Stimulus Intensity for Hand Held and Robotic Transcranial Magnetic Stimulation

BACKGROUND Transcranial Magnetic Stimulation (TMS) is based on a changing magnetic field inducing an electric field in the brain. Conventionally, the TMS coil is mounted to a static holder and the subject is asked to avoid head motion. Additionally, head resting frames have been used. In contrast, our robotized TMS system employs active motion compensation (MC) to maintain the correct coil position. OBJECTIVE/HYPOTHESIS We study the effect of patient motion on TMS. In particular, we compare different coil positioning techniques with respect to the induced electric field. METHODS We recorded head motion for six subjects in three scenarios: (a) avoiding head motion, (b) using a head rest, and (c) moving the head freely. Subsequently, the motion traces were replayed using a second robot to move a sensor to measure the electric field in the target region. These head movements were combined with 2 types of coil positioning: (1) using a coil holder and (2) using robotized TMS with MC. RESULTS After 30 min the induced electric field was reduced by 32.0% and 19.7% for scenarios (1a) and (1b), respectively. For scenarios (2a)-(2c) it was reduced by only 4.9%, 1.4% and 2.0%, respectively, which is a significant improvement (P < 0.05). Furthermore, the orientation of the induced field changed by 5.5°, 7.6°, 0.4°, 0.2°, 0.2° for scenarios (1a)-(2c). CONCLUSION While none of the scenarios required rigid head fixation, using a simple holder to position a coil during TMS can lead to substantial deviations in the induced electric field. In contrast, robotic motion compensation results in clinically acceptable positioning throughout treatment.

[1]  D. Bouhassira,et al.  Long-term maintenance of the analgesic effects of transcranial magnetic stimulation in fibromyalgia , 2011, PAIN®.

[2]  S. Boniface,et al.  Magnetic brain stimulation with a double coil: the importance of coil orientation. , 1992, Electroencephalography and clinical neurophysiology.

[3]  J. Rothwell,et al.  Transcranial magnetic stimulation in cognitive neuroscience – virtual lesion, chronometry, and functional connectivity , 2000, Current Opinion in Neurobiology.

[4]  W. F. Van den Bogaert,et al.  Comparison of plastic and Orfit masks for patient head fixation during radiotherapy: precision and costs. , 1995, International journal of radiation oncology, biology, physics.

[5]  J L Lancaster,et al.  Detailed 3D models of the induced electric field of transcranial magnetic stimulation coils , 2007, Physics in medicine and biology.

[6]  Christian Gerloff,et al.  Dose‐dependent attenuation of auditory phantom perception (tinnitus) by PET‐guided repetitive transcranial magnetic stimulation , 2007, Human brain mapping.

[7]  Achim Schweikard,et al.  Planning and analyzing robotized TMS using virtual reality. , 2006, Studies in health technology and informatics.

[8]  J. Karhu,et al.  Navigated transcranial magnetic stimulation , 2010, Neurophysiologie Clinique/Clinical Neurophysiology.

[9]  P. Rossini,et al.  Consensus paper: Combining transcranial stimulation with neuroimaging , 2009, Brain Stimulation.

[10]  D. Avery,et al.  EEG and the Variance of Motor Evoked Potential Amplitude , 2006, Clinical EEG and neuroscience.

[11]  D. Ridder,et al.  Repetitive transcranial magnetic stimulation (rTMS): a new therapeutic approach in subjective tinnitus? , 2006, Neurophysiologie Clinique/Clinical Neurophysiology.

[12]  C. Umilta,et al.  The use of transcranial magnetic stimulation in cognitive neuroscience: A new synthesis of methodological issues , 2011, Neuroscience & Biobehavioral Reviews.

[13]  Berthold Langguth,et al.  Long-Term Effects of Repetitive Transcranial Magnetic Stimulation (rTMS) in Patients with Chronic Tinnitus , 2005, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[14]  M. Hallett,et al.  Optimal Focal Transcranial Magnetic Activation of the Human Motor Cortex: Effects of Coil Orientation, Shape of the Induced Current Pulse, and Stimulus Intensity , 1992, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[15]  R J Ilmoniemi,et al.  Modeling of the stimulating field generation in TMS. , 1999, Electroencephalography and clinical neurophysiology. Supplement.

[16]  Ulf Ziemann,et al.  TMS in cognitive neuroscience: Virtual lesion and beyond , 2010, Cortex.

[17]  Axel Thielscher,et al.  Effects of transcranial magnetic stimulation on visual evoked potentials in a visual suppression task , 2011, NeuroImage.

[18]  Jason B. Mattingley,et al.  Distance-adjusted motor threshold for transcranial magnetic stimulation , 2007, Clinical Neurophysiology.

[19]  S. Rossi,et al.  Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research , 2009, Clinical Neurophysiology.

[20]  H. Jasper,et al.  The ten-twenty electrode system of the International Federation. The International Federation of Clinical Neurophysiology. , 1999, Electroencephalography and clinical neurophysiology. Supplement.

[21]  S. Rossi,et al.  Controversy: Does repetitive transcranial magnetic stimulation/ transcranial direct current stimulation show efficacy in treating tinnitus patients? , 2008, Brain Stimulation.

[22]  D. Ridder,et al.  rTMS for the treatment of tinnitus: The role of neuronavigation for coil positioning , 2010, Neurophysiologie Clinique/Clinical Neurophysiology.

[23]  Ricardo Insausti,et al.  Quantitative estimation of the primary auditory cortex in human brains , 2004, Brain Research.

[24]  M. Hallett,et al.  Non-invasive differentiation of motor cortical representation of hand muscles by mapping of optimal current directions. , 1994, Electroencephalography and clinical neurophysiology.

[25]  Alexander Schlaefer,et al.  Non‐orthogonal tool/flange and robot/world calibration , 2012, The international journal of medical robotics + computer assisted surgery : MRCAS.

[26]  A. Barker,et al.  NON-INVASIVE MAGNETIC STIMULATION OF HUMAN MOTOR CORTEX , 1985, The Lancet.

[27]  R. Lencer,et al.  The role of prediction and anticipation on age‐related effects on smooth pursuit eye movements , 2011, Annals of the New York Academy of Sciences.

[28]  C. Gerloff,et al.  Moderate therapeutic efficacy of positron emission tomography-navigated repetitive transcranial magnetic stimulation for chronic tinnitus: a randomised, controlled pilot study , 2006, Journal of Neurology, Neurosurgery & Psychiatry.

[29]  Jayashri Kulkarni,et al.  A Randomized Trial of rTMS Targeted with MRI Based Neuro-Navigation in Treatment-Resistant Depression , 2009, Neuropsychopharmacology.

[30]  Edward P. Chronicle,et al.  Development and Positioning Reliability of a TMS Coil Holder for Headache Research , 2005, Headache.

[31]  B. Day,et al.  The effect of magnetic coil orientation on the latency of surface EMG and single motor unit responses in the first dorsal interosseous muscle. , 1994, Electroencephalography and clinical neurophysiology.

[32]  Alexander Muacevic,et al.  Patient motion and targeting accuracy in robotic spinal radiosurgery: 260 single-fraction fiducial-free cases. , 2010, International journal of radiation oncology, biology, physics.

[33]  Daniela Balslev,et al.  Inter-individual variability in optimal current direction for transcranial magnetic stimulation of the motor cortex , 2007, Journal of Neuroscience Methods.

[34]  Lars Richter,et al.  Fast robotic compensation of spontaneous head motion during Transcranial Magnetic Stimulation (TMS) , 2010 .

[35]  Quynh-Thu Le,et al.  Patterns of patient movement during frameless image-guided radiosurgery. , 2003, International journal of radiation oncology, biology, physics.

[36]  P. Trillenberg,et al.  Comparison of stimulus intensity in hand held and robotized motion compensated transcranial magnetic stimulation , 2012, Neurophysiologie Clinique/Clinical Neurophysiology.