Hydrodynamic trap-and-release of single particles using dual-function elastomeric valves: design, fabrication, and characterization

This paper introduces a simple method for trapping and releasing single particles, such as microbeads and living cells, using dual-function elastomeric valves. Our key technique is the utilization of the elastomeric valve as a dual-function removable trap instead of a fixed trap and a separate component for releasing trapped particles, thereby enabling a simple yet effective trap-and-release of particles. We designed, fabricated, and characterized a microfluidic-based device for trapping and releasing single beads by controlling elastomeric valves driven by pneumatic pressure and a fluid flow action. The fluid flow is controlled to ensure that beads flowing in a main stream enter into a branch channel. A bead is trapped by deflected elastomeric valves positioned at the entrance of a branch channel. The trapped bead is easily released by removing the applied pressure. The trapping and releasing of single beads of 21 μm in diameter were successfully performed under an optimized pressure and flow rate ratio. Moreover, we confirmed that continuous trapping and releasing of single beads by repeatedly switching elastomeric valves enables the collection of a controllable number of beads. Our simple method can be integrated into microfluidic systems that require single or multiple particle arrays for quantitative and high-throughput assays in applications within the fields of biology and chemistry.

[1]  Jiang Zhe,et al.  Recent advances in particle and droplet manipulation for lab-on-a-chip devices based on surface acoustic waves. , 2011, Lab on a chip.

[2]  D. Janasek,et al.  A microfluidic array with cellular valving for single cell co-culture. , 2011, Lab on a chip.

[3]  Bingcheng Lin,et al.  Droplet-based microfluidic system for individual Caenorhabditis elegans assay. , 2008, Lab on a chip.

[4]  Luke P. Lee,et al.  Mammalian electrophysiology on a microfluidic platform. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[5]  Fabian Rudolf,et al.  Microfluidic single-cell cultivation chip with controllable immobilization and selective release of yeast cells. , 2012, Lab on a chip.

[6]  Shoji Takeuchi,et al.  Dynamic microarray system with gentle retrieval mechanism for cell-encapsulating hydrogel beads. , 2008, Lab on a chip.

[7]  Gwo-Bin Lee,et al.  The hydrodynamic focusing effect inside rectangular microchannels , 2006 .

[8]  Luke P. Lee,et al.  Nanoliter scale microbioreactor array for quantitative cell biology , 2006, Biotechnology and bioengineering.

[9]  Shoji Takeuchi,et al.  A resettable dynamic microarray device , 2011, Biomedical microdevices.

[10]  A. Ashkin,et al.  Optical trapping and manipulation of viruses and bacteria. , 1987, Science.

[11]  Raymond H. W. Lam,et al.  Building a better cell trap: Applying Lagrangian modeling to the design of microfluidic devices for cell biology , 2008 .

[12]  P. Tracqui,et al.  Optimization of poly-di-methyl-siloxane (PDMS) substrates for studying cellular adhesion and motility , 2008 .

[13]  A. Abate,et al.  Microfluidic sorting with high-speed single-layer membrane valves , 2010 .

[14]  Bruce K. Gale,et al.  Determining the optimal PDMS–PDMS bonding technique for microfluidic devices , 2008 .

[15]  Y. Oh,et al.  A Multicellular Spheroid Formation and Extraction Chip Using Removable Cell Trapping Barriers , 2011 .

[16]  S. Timoshenko,et al.  THEORY OF PLATES AND SHELLS , 1959 .

[17]  Shoji Takeuchi,et al.  A dynamic microarray device for paired bead-based analysis. , 2010, Lab on a chip.

[18]  S. Takeuchi,et al.  A Dynamic Microarray with Pneumatic Valves for Selective Trapping and Releasing of Microbeads , 2009, 2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems.

[19]  Charles M Schroeder,et al.  A microfluidic-based hydrodynamic trap: design and implementation. , 2011, Lab on a chip.

[20]  R. Jaenisch,et al.  Microfluidic Control of Cell Pairing and Fusion , 2009, Nature Methods.

[21]  Luke P. Lee,et al.  Dynamic single cell culture array. , 2006, Lab on a chip.

[22]  Mehmet Toner,et al.  A microfabrication-based dynamic array cytometer. , 2002, Analytical chemistry.

[23]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[24]  David A. Weitz,et al.  Single-layer membrane valves for elastomeric microfluidic devices , 2008 .

[25]  Martin A. M. Gijs,et al.  Magnetic bead handling on-chip: new opportunities for analytical applications , 2004 .

[26]  T. Laurell,et al.  Review of cell and particle trapping in microfluidic systems. , 2009, Analytica chimica acta.

[27]  Minoru Seki,et al.  Microfluidic devices for size-dependent separation of liver cells , 2007, Biomedical microdevices.

[28]  K. Suh,et al.  Pumpless, selective docking of yeast cells inside a microfluidic channel induced by receding meniscus. , 2006, Lab on a chip.

[29]  Shoji Takeuchi,et al.  A trap-and-release integrated microfluidic system for dynamic microarray applications , 2007, Proceedings of the National Academy of Sciences.

[30]  Young-Ho Cho,et al.  A multicellular spheroid formation and extraction chip using removable cell trapping barriers. , 2011, Lab on a chip.