Quality control of CarboEurope flux data – Part 2: Inter-comparison of eddy-covariance software

Abstract. As part of the quality assurance and quality control activities within the CarboEurope-IP network, a comparison of eddy-covariance software was conducted. For four five-day datasets, CO2 flux estimates were calculated by seven commonly used software packages to assess the uncertainty of CO2 flux estimates due to differences in post-processing. The datasets originated from different sites representing different commonly applied instrumentation and different canopy structures to cover a wide range of realistic conditions. Data preparation, coordinate rotation and the implementation of the correction for high frequency spectral losses were identified as crucial processing steps leading to significant discrepancies in the CO2 flux results. The overall comparison indicated a good although not yet perfect agreement among the different software within 5–10% difference for 30-min CO2 flux values. Conceptually different ideas about the selection and application of processing steps were a main reason for the differences in the CO2 flux estimates observed. A balance should be aspired between scientific freedom on the one hand, in order to advance methodical issues, and standardisation of procedures on the other hand, in order to obtain comparable fluxes for multi-site synthesis studies.

[1]  Thomas Foken,et al.  Post-Field Data Quality Control , 2004 .

[2]  William J. Massman,et al.  Handbook of micrometeorology : a guide for surface flux measurement and analysis , 2004 .

[3]  M. Molen,et al.  Sonic anemometer (co)sine response and flux measurement: II. The effect of introducing an angle of attack dependent calibration , 2004 .

[4]  T. Foken,et al.  Scalar Similarity for Relaxed Eddy Accumulation Methods , 2006 .

[5]  H. Mengelkamp,et al.  Evaporation over a Heterogeneous Land Surface: EVA_GRIPS and the LITFASS-2003 Experiment—An Overview , 2006 .

[6]  W. Oechel,et al.  FLUXNET: A New Tool to Study the Temporal and Spatial Variability of Ecosystem-Scale Carbon Dioxide, Water Vapor, and Energy Flux Densities , 2001 .

[7]  F. Chapin,et al.  A Comparative Approach to Regional Variation in Surface Fluxes Using Mobile Eddy Correlation Towers , 1997 .

[8]  T. Foken,et al.  Tools for quality assessment of surface-based flux measurements , 1996 .

[9]  E. Swiatek,et al.  Density Fluctuations and Use of the Krypton Hygrometer in Surface Flux Measurements , 1993 .

[10]  William J. Massman,et al.  Consequences of Incomplete Surface Energy Balance Closure for CO2 Fluxes from Open-Path CO2/H2O Infrared Gas Analysers , 2006 .

[11]  Walter Senn,et al.  A cospectral correction model for measurement of turbulent NO2 flux , 1995 .

[12]  Thomas Foken,et al.  New Equations For Sonic Temperature Variance And Buoyancy Heat Flux With An Omnidirectional Sonic Anemometer , 2001 .

[13]  Thomas Foken,et al.  The energy balance experiment EBEX-2000 , 2002 .

[14]  K. E. Moore,et al.  Importance of Low-Frequency Contributions to Eddy Fluxes Observed over Rough Surfaces , 2001 .

[15]  C. Bernhofer,et al.  The Energy Balance Experiment EBEX-2000. Part I: overview and energy balance , 2007 .

[16]  F. Wimmer,et al.  Some aspects of the energy balance closure problem , 2006 .

[17]  R. Desjardins,et al.  Scale analysis of airborne flux measurements over heterogeneous terrain in a boreal ecosystem , 2007 .

[18]  T. Foken The energy balance closure problem: an overview. , 2008, Ecological applications : a publication of the Ecological Society of America.

[19]  J. Kaimal,et al.  Spectral Characteristics of Surface-Layer Turbulence , 1972 .

[20]  Ü. Rannik,et al.  Gap filling strategies for defensible annual sums of net ecosystem exchange , 2001 .

[21]  T. Foken,et al.  Update of a Footprint-Based Approach for the Characterisation of Complex Measurement Sites , 2006 .

[22]  Arnold F. Moene,et al.  The principles of surface flux physics: theory, practice and description of the ECPACK library , 2004 .

[23]  T. W. Horst On Frequency Response Corrections for Eddy Covariance Flux Measurements , 2000 .

[24]  B. Law,et al.  Handbook of Micrometeorology , 2005 .

[25]  Thomas Foken,et al.  Impact of post-field data processing on eddy covariance flux estimates and energy balance closure , 2006 .

[26]  Jørgen Højstrup,et al.  A simple model for the adjustment of velocity spectra in unstable conditions downstream of an abrupt change in roughness and heat flux , 1981 .

[27]  Corinna Rebmann,et al.  Methodology for data acquisition, storage, and treatment , 2003 .

[28]  A. Delany,et al.  A scalar similarity study based on surface layer ozone measurements over cotton during the California Ozone Deposition Experiment , 1998 .

[29]  Ü. Rannik,et al.  Estimates of the annual net carbon and water exchange of forests: the EUROFLUX methodology , 2000 .

[30]  Dennis Baldocchi,et al.  On Measuring Net Ecosystem Carbon Exchange Over Tall Vegetation on Complex Terrain , 2000, Boundary-Layer Meteorology.

[31]  J. Wilczak,et al.  Sonic Anemometer Tilt Correction Algorithms , 2001 .

[32]  Corinna Rebmann,et al.  EddySoft : Dokumentation of a Software Package to Acquire and Process Eddy Covariance Data , 2007 .

[33]  Thomas Foken,et al.  Processing and quality control of flux data during LITFASS-2003 , 2006 .

[34]  A. Kowalski,et al.  Consequences of Uncertainties in CO2 Density for Estimating Net Ecosystem CO2 Exchange by Open-path Eddy Covariance , 2008 .

[35]  Remo Guidieri Res , 1995, RES: Anthropology and Aesthetics.

[36]  Corinna Rebmann,et al.  A combination of quality assessment tools for eddy covariance measurements with footprint modelling for the characterisation of complex sites , 2004 .

[37]  P. Mason Atmospheric boundary layer flows: Their structure and measurement , 1995 .

[38]  George Burba,et al.  Fine-wire thermometer to correct CO2 fluxes by open-path analyzers for artificial density fluctuations , 2007 .

[39]  J. Højstrup A statistical data screening procedure , 1993 .

[40]  K. M. King,et al.  Comparison of eddy-covariance measurements of CO2 fluxes by open- and closed-path CO2 analysers , 1992 .

[41]  Matthias Mauder,et al.  Innovative gap-filling strategy for annual sums of CO2 net ecosystem exchange , 2006 .

[42]  A. Verhoef,et al.  A system to measure surface fluxes of momentum, sensible heat, water vapour and carbon dioxide , 1997 .

[43]  Riccardo Valentini,et al.  Fluxes of Carbon, Water and Energy of European Forests , 2003, Ecological Studies.

[44]  M. Aubinet,et al.  Horizontal and Vertical Co2 Advection In A Sloping Forest , 2003 .

[45]  Thomas Foken,et al.  The energy balance experiment EBEX-2000. Part II: Intercomparison of eddy-covariance sensors and post-field data processing methods , 2007 .

[46]  Xuhui Lee,et al.  On micrometeorological observations of surface-air exchange over tall vegetation , 1998 .

[47]  A. Dolman,et al.  Sonic anemometer (co)sine response and flux measurement I. The potential for (co)sine error to affect sonic anemometer-based flux measurements , 2003 .

[48]  H. D. Bruin,et al.  Oxygen Sensitivity of Krypton and Lyman-α Hygrometers , 2003 .

[49]  M. Mauder Interactive comment on “Quality control of CarboEurope flux data – Part II: Inter-comparison of eddy-covariance software” by M. Mauder et al , 2007 .

[50]  E. K. Webb,et al.  Correction of flux measurements for density effects due to heat and water vapour transfer , 1980 .

[51]  Yadvinder Malhi,et al.  A Re-Evaluation of Long-Term Flux Measurement Techniques Part I: Averaging and Coordinate Rotation , 2003 .

[52]  C. J. Moore Frequency response corrections for eddy correlation systems , 1986 .

[53]  Dean Vickers,et al.  Quality Control and Flux Sampling Problems for Tower and Aircraft Data , 1997 .

[54]  Frans T. M. Nieuwstadt,et al.  Temperature measurement with a sonic anemometer and its application to heat and moisture fluxes , 1983 .

[55]  D. Fitzjarrald,et al.  Observing subcanopy CO2 advection , 2004 .

[56]  W. Oechel,et al.  Energy balance closure at FLUXNET sites , 2002 .