Automatic filtering of outliers in RR intervals before analysis of heart rate variability in Holter recordings: a comparison with carefully edited data

BackgroundUndetected arrhythmic beats seriously affect the power spectrum of the heart rate variability (HRV). Therefore, the series of RR intervals are normally carefully edited before HRV is analysed, but this is a time consuming procedure when 24-hours recordings are analysed. Alternatively, different methods can be used for automatic removal of arrhythmic beats and artefacts. This study compared common frequency domain indices of HRV when determined from manually edited and automatically filtered RR intervals.Methods and ResultsTwenty-four hours Holter recordings were available from 140 healthy subjects of age 1-75 years. An experienced technician carefully edited all recordings. Automatic filtering was performed using a recursive procedure where RR intervals were removed if they differed from the mean of the surrounding RR intervals with more than a predetermined limit (ranging from 10% to 50%). The filtering algorithm was evaluated by replacing 1% of the beats with synthesised ectopic beats. Power spectral analysis was performed before and after filtering of both the original edited data and the noisy data set. The results from the analysis using the noisy data were used to define an age-based filtering threshold. The age-based filtration was evaluated with completely unedited data, generated by removing all annotations from the series of RR intervals, and then comparing the resulting HRV indices with those obtained using edited data. The results showed equivalent results after age-based filtration of both the edited and unedited data sets, where the differences in HRV indices obtained by different preprocessing methods were small compared to the mean values within each age group.ConclusionsThe study showed that it might not be necessary to perform the time-consuming careful editing of all detected heartbeats before HRV is analysed in Holter recordings.In most subjects, it is sufficient to perform the regular editing needed for valid arrhythmia analyses, and then remove undetected ectopic beats and artefacts by age-based filtration of the series of RR intervals, particularly in subjects older than 30 years.

[1]  W. Lieb,et al.  Effects of Gender and Aging on Differential Autonomic Responses to Orthostatic Maneuvers , 2008, Journal of cardiovascular electrophysiology.

[2]  M Ericson,et al.  Automatic computerized analysis of heart rate variability with digital filtering of ectopic beats. , 2001, Clinical physiology.

[3]  G. Breithardt,et al.  Heart rate variability: standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. , 1996 .

[4]  Lionel Tarassenko,et al.  Quantifying errors in spectral estimates of HRV due to beat replacement and resampling , 2005, IEEE Transactions on Biomedical Engineering.

[5]  Marek Malik,et al.  Prevalent Low-Frequency Oscillation of Heart Rate: Novel Predictor of Mortality After Myocardial Infarction , 2004, Circulation.

[6]  Donald J. Schuirmann A comparison of the Two One-Sided Tests Procedure and the Power Approach for assessing the equivalence of average bioavailability , 1987, Journal of Pharmacokinetics and Biopharmaceutics.

[7]  O Odemuyiwa,et al.  Influence of recognition errors of computerised analysis of 24-hour electrocardiograms on the measurement of spectral components of heart rate variability. , 1993, International journal of bio-medical computing.

[8]  W. Stevenson,et al.  Patterns of beat-to-beat heart rate variability in advanced heart failure. , 1992, American heart journal.

[9]  S. Jensen,et al.  Outcome of heart rate variability and ventricular late potentials after liver transplantation for familial amyloidotic polyneuropathy , 2008, Amyloid : the international journal of experimental and clinical investigation : the official journal of the International Society of Amyloidosis.

[10]  D. Ferguson,et al.  Problems in measuring heart rate variability of patients with congestive heart failure. , 1992, Journal of electrocardiology.

[11]  D H Singer,et al.  Twenty-four hour time domain heart rate variability and heart rate: relations to age and gender over nine decades. , 1998, Journal of the American College of Cardiology.

[12]  V. Padmanabhan,et al.  Automatic measurement of long-term heart rate variability by implanted single-chamber devices , 1999, Medical & Biological Engineering & Computing.

[13]  Urban Wiklund,et al.  Abnormal Heart Rate Variability and Subtle Atrial Arrhythmia in Patients with Familial Amyloidotic Polyneuropathy , 2008, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc.

[14]  Phyllis K Stein,et al.  Sometimes Higher Heart Rate Variability Is Not Better Heart Rate Variability: Results of Graphical and Nonlinear Analyses , 2005, Journal of cardiovascular electrophysiology.