Optimal sun-shading design for enhanced daylight illumination of subtropical classrooms

This study investigates the feasibility of fitting windows with sun-shadings in order to minimize the lighting power costs in daylight-illuminated classrooms lit from a single side in subtropical regions. An IES-CPC model is created of a representative classroom in Taiwan, and a series of simulations is performed to determine the average illuminance value and the uniformity of the illuminance distribution in the classroom under various lighting conditions with no sun-shadings fitted to the window. The numerical results are found to be in good agreement with the experimental measurements obtained using an array of nine-channel photometers. Having confirmed the validity of the simulation scheme, the illumination properties of four different sun-shading designs are considered. The results show that a double-layered sun-shading represents the optimal sun-shading design in terms of achieving a uniform illumination distribution within the classroom. Given appropriate physical dimensions, this daylight access device achieves the minimum illuminance requirement of 500 lx and improves the lighting uniformity ratio from 0.25–0.35 to 0.40–0.42. Furthermore, using this sun-shading device, the required illuminance ratio of 0.5 can be obtained simply by switching on one of the three rows of lights in the classroom. Accordingly, the daylight access device not only improves the illuminance conditions within the classroom, but also reduces the lighting power cost by 71.5% compared to the case where all of the lights are turned on.

[1]  Takashi Inoue,et al.  Solar shading and daylighting by means of autonomous responsive dimming glass: Practical application , 2003 .

[2]  I. Guedi Capeluto,et al.  Energy performance of the self-shading building envelope , 2003 .

[3]  Constantinos A. Balaras,et al.  Potential for energy conservation in apartment buildings , 2000 .

[4]  Danny H.W. Li,et al.  Evaluation of lighting performance in office buildings with daylighting controls , 2001 .

[5]  Constantinos A. Balaras,et al.  Energy conservation and retrofitting potential in Hellenic hotels , 1996 .

[6]  Nyuk Hien Wong,et al.  Effect of external shading devices on daylighting penetration in residential buildings , 2004 .

[7]  C. M. Chiang,et al.  Predicted Simulation on the Lighting Energy Saving in a Classroom Using the Sun Shading as the Daylight-introducing Device , 2004 .

[8]  John Mardaljevic,et al.  The BRE-IDMP dataset: a new benchmark for the validation of illuminance prediction techniques , 2001 .

[9]  Danny H.W. Li,et al.  An investigation of daylighting performance and energy saving in a daylit corridor , 2003 .

[10]  M. Atif,et al.  Energy performance of daylight-linked automatic lighting control systems in large atrium spaces: report on two field-monitored case studies , 2003 .

[11]  Nyuk Hien Wong,et al.  Thermal comfort in classrooms in the tropics , 2003 .

[12]  Aris Tsangrassoulis,et al.  Theoretical and experimental analysis of daylight performance for various shading systems , 1996 .

[13]  Magali Bodart,et al.  Global energy savings in offices buildings by the use of daylighting , 2002 .

[14]  Ralph L Knowles,et al.  The solar envelope: its meaning for energy and buildings , 2003 .