Exergetic Analysis of Solar Concentrator Aided Natural Gas Fired Combined Cycle Power Plant

This article deals with comparative energy and exergetic analysis for evaluation of natural gas fired combined cycle power plant and solar concentrator aided (feed water heating and low pressure steam generation options) natural gas fired combined cycle power plant. Heat Transfer analysis of Linear Fresnel reflecting solar concentrator (LFRSC) is used to predict the effect of focal distance and width of reflector upon the reflecting surface area. Performance analysis of LFRSC with energetic and exergetic methods and the effect, of concentration ratio and inlet temperature of the fluid is carried out to determine, overall heat loss coefficient of the circular evacuated tube absorber at different receiver temperatures. An instantaneous increase in power generation capacity of about 10% is observed by substituting solar thermal energy for feed water heater and low pressure steam generation. It is observed that the utilization of solar energy for feed water heating and low pressure steam generation is more effective based on exergetic analysis rather than energetic analysis. Furthermore, for a solar aided feed water heating and low pressure steam generation, it is found that the land area requirement is 7 ha/MW for large scale solar thermal storage system to run the plant for 24 h.

[1]  S. C. Kaushik,et al.  Second-law based thermodynamic analysis of Brayton/Rankine combined power cycle with reheat , 2004 .

[2]  Y. Çengel,et al.  Thermodynamics : An Engineering Approach , 1989 .

[3]  Bale V. Reddy,et al.  Exergy analysis of a natural gas fired combined cycle power generation unit , 2007 .

[4]  T. Srinivas,et al.  Study of a deaerator location in triple-pressure reheat combined power cycle , 2009 .

[5]  P. L. Dhar,et al.  Optimization of Waste Heat Recovery Boiler of a Combined Cycle Power Plant , 1996 .

[6]  S. C. Kaushik,et al.  Exergetic utilization of solar energy for feed water preheating in a conventional thermal power plant , 2009 .

[7]  Panna Lal Singh,et al.  Thermal performance of linear Fresnel reflecting solar concentrator with trapezoidal cavity absorbers , 2010 .

[8]  D. Popov An option for solar thermal repowering of fossil fuel fired power plants , 2011 .

[9]  Tara C. Kandpal,et al.  Optical design and concentration characteristics of linear Fresnel reflector solar concentrators—I. Mirror elements of varying width , 1991 .

[10]  K. S. Reddy,et al.  4-E (Energy, Exergy, Environment, and Economic) analysis of solar thermal aided coal-fired power plants , 2010 .

[11]  Armando C. Oliveira,et al.  Numerical simulation of a trapezoidal cavity receiver for a linear Fresnel solar collector concentrator , 2011 .

[12]  W. Beckman,et al.  Solar Engineering of Thermal Processes , 1985 .

[13]  M. Behnia,et al.  Modelling of Parabolic Trough Direct Steam Generation Solar Collectors , 1998, Renewable Energy.

[14]  Tara C. Kandpal,et al.  Optical and thermal performance evaluation of a linear fresnel reflector solar concentrator , 1989 .

[15]  Mortaza Aghbashlo,et al.  A review on exergy analysis of drying processes and systems , 2013 .

[16]  R. Petela Exergy of Heat Radiation , 1964 .

[17]  T. C. Kandpal,et al.  Designs and performance characteristics of a linear fresnel reflector solar concentrator with a flat vertical absorber , 1990 .

[18]  Gitanjali Yadav,et al.  Performance study of a linear Fresnel concentrating solar device , 1999 .

[19]  Panna Lal Singh,et al.  Heat loss study of trapezoidal cavity absorbers for linear solar concentrating collector , 2010 .