Cooperative T1 and T2 effects on contrast using a new driven inversion spin‐echo (DISE) MRI pulse sequence

A pulse sequence is presented for obtaining a single image with combined T1/T2 weighting. T2 relaxation is made to increase intensity, in cooperation with the effect of T1 relaxation, by providing T2 weighting with a 90°‐180°‐90° driven inversion pulse triplet in an inversion recovery method. Unlike the inversion spin‐echo method having a short inversion time (TI), signals in the new driven inversion spin‐echo (DISE) method need not be negative and the most T1‐sensitive region of the recovery curve can be used. Selecting sensitivity to one relaxation time does not degrade the sensitivity to the other relaxation time. T1 sensitivity is thus extended to longer echo times (TE intervals), T2 sensitivity is extended to longer TI intervals, and the combined Tl / T2‐weighted technique with intermediate TE and T1 has highly cooperative and near‐maximal T1 and T2 effects on contrast. Intensity is not multiplicatively degraded by T1 and T2weighting so that the signal‐to‐noise of the combined T1/T2 ‐weighted method is high. High intensity and TI and T2 cooperatively occur for a much wider range of relaxation times, and especially for images heavily weighted to the pathologic intermediate and long T1 and T2 Rgime. © 1990 Academic Press, Inc.

[1]  J N Lee,et al.  Improved precision in calculated T1 MR images using multiple spin-echo acquisition. , 1986, Journal of computer assisted tomography.

[2]  R. Tycko,et al.  Broadband Population Inversion , 1983 .

[3]  T E Conturo,et al.  AUR Memorial Award. Two computer models for selection of optimal magnetic resonance imaging (MRI) pulse sequence timing. , 1984, Investigative radiology.

[4]  A. Haase,et al.  Rapid NMR Imaging Using Low Flip-Angle Pulses , 2004 .

[5]  J N Lee,et al.  Synthesized MR images: comparison with acquired images. , 1985, Radiology.

[6]  B R Rosen,et al.  Selective Saturation NMR Imaging , 1984, Journal of computer assisted tomography.

[7]  B R Rosen,et al.  Spin lattice relaxation time measurements in two-dimensional nuclear magnetic resonance imaging: corrections for plane selection and pulse sequence. , 1984, Journal of computer assisted tomography.

[8]  R. R. Ernst,et al.  Application of Fourier Transform Spectroscopy to Magnetic Resonance , 1966 .

[9]  Ray Freeman,et al.  Fourier Transform Study of NMR Spin-Lattice Relaxation by , 1971 .

[10]  S. Riederer,et al.  Efficient pulse sequence for multisection dual-repetition time MR image acquisition. , 1988, Radiology.

[11]  G M Bydder,et al.  MR Imaging: Clinical Use of the Inversion Recovery Sequence , 1985, Journal of computer assisted tomography.

[12]  L Kaufman,et al.  Analytical tools for magnetic resonance imaging. , 1984, Radiology.

[13]  L. Hall,et al.  Measurement of proton spin-lattice relaxation rates of model phantoms in chemical imaging , 1985 .

[14]  W. Edelstein,et al.  A signal-to-noise calibration procedure for NMR imaging systems. , 1984, Medical physics.

[15]  E. T. Jaynes,et al.  MATRIX TREATMENT OF NUCLEAR INDUCTION , 1955 .

[16]  Becker Ed,et al.  Driven equilibrium Fourier transform spectroscopy. A new method for nuclear magnetic resonance signal enhancement. , 1969 .

[17]  J C Gore,et al.  Toward an automated analysis system for nuclear magnetic resonance imaging. I. Efficient pulse sequences for simultaneous T1-T2 imaging. , 1986, Medical physics.

[18]  R. Grossman,et al.  High-field MRI of hemorrhagic cortical infarction. , 1986, AJNR. American journal of neuroradiology.

[19]  H. T. Edzes An analysis of the use of pulse multiplets in the single scan determination of spin-lattice relaxation rates , 1975 .

[20]  P A Bottomley,et al.  Signal, Noise, and Contrast in Nuclear Magnetic Resonance (NMR) Imaging , 1983, Journal of computer assisted tomography.

[21]  T. Foster,et al.  A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. , 1984, Medical physics.

[22]  T. Conturo,et al.  Improved determination of spin density, T1 and T2 from a three-parameter fit to multiple-delay-multiple-echo (MDME) NMR images. , 1986, Physics in medicine and biology.

[23]  H. Carr STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE , 1958 .

[24]  Ray Freeman,et al.  NMR population inversion using a composite pulse , 1979 .

[25]  R. Hendrick Sampling time effects on signal-to-noise and contrast-to-noise ratios in spin-echo MRI. , 1987, Magnetic resonance imaging.

[26]  J R MacFall,et al.  Mechanisms of Contrast in NMR Imaging , 1984, Journal of computer assisted tomography.

[27]  P. Narayana,et al.  Pulse sequence design for volume selective excitation in magnetic resonance. , 1987, Medical physics.

[28]  R R Price,et al.  Simplified mathematical description of longitudinal recovery in multiple‐echo sequences , 1987, Magnetic resonance in medicine.

[29]  J N Lee,et al.  Pulse sequence extrapolation with MR image synthesis. , 1986, Radiology.

[30]  J. Ford,et al.  Accurate T1 and spin density NMR images. , 1985, Medical physics.

[31]  J N Lee,et al.  The contrast‐to‐noise in relaxation time, synthetic, and weighted‐sum MR images , 1987, Magnetic resonance in medicine.