Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images?

PURPOSE To qualitatively and quantitatively compare virtual nonenhanced (VNE) data sets derived from dual-energy (DE) computed tomography (CT) with true nonenhanced (TNE) data sets in the same patients and to calculate potential radiation dose reductions for a dual-phase renal multidetector CT compared with a standard triple-phase protocol. MATERIALS AND METHODS This prospective study was approved by the institutional review board; all patients provided written informed consent. Seventy one men (age range, 30-88 years) and 39 women (age range, 22-87 years) underwent preoperative DE CT that included unenhanced, DE nephrographic, and delayed phases. DE CT parameters were 80 and 140 kV, 96 mAs (effective). Collimation was 14 x 1.2 mm. CT numbers were measured in renal parenchyma and tumor, liver, aorta, and psoas muscle. Image noise was measured on TNE and VNE images. Exclusion of relevant anatomy with the 26-cm field of view detector was quantified with a five-point scale (0 = none, 4 = >75%). Image quality and noise (1 = none, 5 = severe) and acceptability for VNE and TNE images were rated. Effective radiation doses for DE CT and TNE images were calculated. Differences were tested with a Student t test for paired samples. RESULTS Mean CT numbers (+/- standard deviation) on TNE and VNE images, respectively, for renal parenchyma were 30.8 HU +/- 4.0 and 31.6 HU +/- 7.1, P = .29; liver, 55.8 HU +/- 8.6 and 57.8 HU +/- 10.1, P = .11; aorta, 42.1 HU +/- 4.1 and 43.0 HU +/- 8.8, P = .16; psoas, 47.3 HU +/- 5.6 and 48.1 HU +/- 9.3 HU, P = .38. No exclusion of the contralateral kidney was seen in 50 patients, less than 25% was seen in 43, 25%-50% was seen in 13, and 50%-75% was seen in four. Mean image noise was 1.71 +/- 0.71 for VNE and 1.22 +/- 0.45 for TNE (P < .001); image quality was 1.70 HU +/- 0.72 for VNE and 1.15 HU +/- 0.36 for TNE (P < .0001). In all but three patients radiologists accepted VNE images as replacement for TNE images. Mean effective dose for DE CT scans of the abdomen was 5.21 mSv +/- 1.86 and that for nonenhanced scans was 4.97 mSv +/- 1.43. Mean dose reduction by omitting the TNE scan was 35.05%. CONCLUSION In patients with renal masses, DE CT can provide high-quality VNE data sets, which are a reasonable approximation of TNE data sets. Integration of DE scanning into a renal mass protocol will lower radiation exposure by 35%.

[1]  M. Macari,et al.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen , 2008, European Radiology.

[2]  M. Reiser,et al.  Material differentiation by dual energy CT: initial experience , 2007, European Radiology.

[3]  Hersh Chandarana,et al.  Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms--initial observations. , 2008, Radiology.

[4]  K. Stierstorfer,et al.  Technical principles of dual source CT. , 2008, European journal of radiology.

[5]  R. Carmi,et al.  Material separation with dual-layer CT , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[6]  M. Tillich,et al.  Multiphasic helical CT of the kidney: increased conspicuity for detection and characterization of small (< 3-cm) renal masses. , 1997, Radiology.

[7]  P. Ramchandani,et al.  Multiphasic renal CT: comparison of renal mass enhancement during the corticomedullary and nephrographic phases. , 1996, Radiology.

[8]  G. Chiro,et al.  Tissue signatures with dual-energy computed tomography. , 1979, Radiology.

[9]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[10]  G Gamsu,et al.  Quantification of calcium in solitary pulmonary nodules using single- and dual-energy CT. , 1982, Radiology.

[11]  H. Genant,et al.  Quantitative bone mineral analysis using dual energy computed tomography. , 1977, Investigative radiology.

[12]  C. Becker,et al.  Dose reduction and image quality in MDCT colonography using tube current modulation. , 2006, AJR. American journal of roentgenology.

[13]  C. Cann,et al.  Noninvasive quantitation of liver iron in dogs with hemochromatosis using dual-energy CT scanning. , 1981, Investigative radiology.

[14]  G. Israel,et al.  How I do it: evaluating renal masses. , 2005, Radiology.