A Nonintrusive Winding Heating Method for Induction Motor Using Soft Starter for Preventing Moisture Condensation

Moisture condensation may cause degradation of key motor components when a motor is de-energized. To prevent moisture condensation, a motor's temperature must be maintained higher than the ambient temperature when de-energized. This paper proposes a nonintrusive motor heating technique using soft starters. By controlling the operation of the solid-state switches in soft starters, adjustable ac current can be injected into the three phases of the stator windings without inducing any output torque. The motor temperature can therefore be maintained at a desired temperature due to the heat dissipation during current injection. In addition, two motor temperature control approaches are proposed in this paper to minimize the required energy consumption for preventing moisture condensation. The proposed technique is experimentally validated on a 7.5-hp ODP (open drip proof) induction motor. The experimental results show that the average stator winding temperature can reach 9 ° above the ambient temperature with acceptable current magnitudes. In addition, it is shown that the motor temperature rise can be controlled by adjusting the operation of the solid-state switches in soft starters. The importance of the proposed technique lies in its noninvasive nature: the technique only uses the existing hardware of soft starters; the motor's condition is not interrupted since no output torque is induced during the current injection. The proposed winding heating technique can be easily extended to other types of ac machines or inverter-fed applications.

[1]  Ieee Standards Board IEEE standard test procedure for polyphase induction motors and generators , 1992 .

[2]  Daumantas V. Dikinis,et al.  Solid-State Control-Low Voltage Heating of Motors , 1975, IEEE Transactions on Industry Applications.

[3]  Walter R. Keithly,et al.  A Unique Solution to Improving Motor Winding Life in Medium-Voltage Motors , 1984, IEEE Transactions on Industry Applications.

[4]  H. P. Walker,et al.  Severe Moisture Conditioning Uncovers Weaknesses in Conventional Motor Insulation Systems for Naval Shipboard Use , 1961, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[5]  Robert J. Brighton,et al.  Why Overload Relays Do NOT Always Protect Motors , 1982, IEEE Transactions on Industry Applications.

[6]  T.G. Habetler,et al.  A DC Signal Injection-Based Thermal Protection Scheme for Soft-Starter-Connected Induction Motors , 2009, IEEE Transactions on Industry Applications.

[7]  H. G. Sedding,et al.  Development of a continuous on-line partial discharge monitoring system for medium voltage motors , 1997 .

[8]  Mohd Jailani Mohd Nor,et al.  Statistical analysis of sound and vibration signals for monitoring rolling element bearing condition , 1998 .

[9]  S. Williamson,et al.  Analysis of Cage Induction Motors with Stator Winding Faults , 1985, IEEE Power Engineering Review.

[10]  W.R. Finley,et al.  Storage of electric motors , 1995, Conference Record of 1995 Annual Pulp and Paper Industry Technical Conference.

[11]  Bin Lu,et al.  Impaired-Cooling-Condition Detection Using DC-Signal Injection for Soft-Starter-Connected Induction Motors , 2009, IEEE Transactions on Industrial Electronics.

[12]  Yi Du,et al.  Improving Thermal Recovery Time for Soft-Starter-Connected AC Motors With Intermittent Periodic Duty Cycles , 2009, IEEE Transactions on Industry Applications.

[13]  J. Malinowski,et al.  AC induction motor specifications-an update on currently available procedures and options , 2002, Conference Record of the 2002 Annual Pulp and Paper Industry Technical Conference (Cat. No.02CH37352).

[14]  S. E. Zocholl,et al.  Motor analysis and thermal protection , 1990 .

[15]  Thomas G. Habetler,et al.  A Remote and Sensorless Stator Winding Resistance Estimation Method for Thermal Protection of Soft-Starter-Connected Induction Machines , 2008, IEEE Transactions on Industrial Electronics.

[16]  J. Penman,et al.  Condition monitoring of electrical drives , 1986 .

[17]  Austin H. Bonnett,et al.  Rotor Failures in Squirrel Cage Induction Motors , 1986, IEEE Transactions on Industry Applications.