Optically monitored drug delivery patch based on porous silicon and polymer microneedles

Fabrication and characterization of an optically monitored hybrid patch for local administration of drugs, based on polymeric micro-needles and a porous silicon free-standing membrane, are reported. The micro-needles are realized by an innovative photolithographic approach that allows fine tuning of geometrical parameters, using polyethylene glycol and a commercial photo-catalyzer. The porous silicon multilayer not only increases the storage of a relevant amount of the drug, but also offers a continuous, naked-eye monitoring of the drug delivery process. As a proof-of-concept experiment, we report our results on the release of a dye molecule (fluorescein, 332 Da) in a phosphate saline buffer.

[1]  Thakur Raghu Raj Singh,et al.  Hydrogel-Forming Microneedle Arrays for Enhanced Transdermal Drug Delivery , 2012, Advanced functional materials.

[2]  E. O’Cearbhaill,et al.  Toward Biofunctional Microneedles for Stimulus Responsive Drug Delivery. , 2015, Bioconjugate chemistry.

[3]  Luca De Stefano,et al.  A Photolithographic Approach to Polymeric Microneedles Array Fabrication , 2015, Materials.

[4]  Ryan F. Donnelly,et al.  A proposed model membrane and test method for microneedle insertion studies , 2014, International journal of pharmaceutics.

[5]  Ivo Rendina,et al.  Porous silicon-based optical biosensors and biochips , 2007 .

[6]  L. Canham,et al.  Silicon: the evolution of its use in biomaterials. , 2015, Acta biomaterialia.

[7]  Giuseppe Barillaro,et al.  Microneedles for Transdermal Biosensing: Current Picture and Future Direction , 2015, Advanced healthcare materials.

[8]  Nitin Afzulpurkar,et al.  Micro Electromechanical Systems (MEMS) Based Microfluidic Devices for Biomedical Applications , 2011, International journal of molecular sciences.

[9]  Christopher S. Chen,et al.  Cells lying on a bed of microneedles: An approach to isolate mechanical force , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[10]  Ryan F. Donnelly,et al.  Microneedle-based drug delivery systems: Microfabrication, drug delivery, and safety , 2010, Drug delivery.

[11]  Ivo Rendina,et al.  Protein‐Modified Porous Silicon Nanostructures , 2008 .

[12]  M. Allen,et al.  Microfabricated microneedles: a novel approach to transdermal drug delivery. , 1998, Journal of pharmaceutical sciences.

[13]  P. Uzor,et al.  Transdermal Drug Delivery , 2012 .

[14]  S. D. Collins,et al.  Microneedle array for transdermal biological fluid extraction and in situ analysis , 2004 .

[15]  Bo Li,et al.  Novel engineered systems for oral, mucosal and transdermal drug delivery , 2013, Journal of drug targeting.

[16]  M. Prausnitz Reversible skin permeabilization for transdermal delivery of macromolecules. , 1997, Critical reviews in therapeutic drug carrier systems.

[17]  Roger Narayan,et al.  Multiplexed and Switchable Release of Distinct Fluids from Microneedle Platforms via Conducting Polymer Nanoactuators for Potential Drug Delivery. , 2012, Sensors and actuators. B, Chemical.

[18]  Pietro Ferraro,et al.  Electro‐Drawn Drug‐Loaded Biodegradable Polymer Microneedles as a Viable Route to Hypodermic Injection , 2014 .

[19]  Luigi Moretti,et al.  Time-resolved sensing of chemical species in porous silicon optical microcavity , 2004 .

[20]  S. d'Auria,et al.  Glutamine-binding protein from Escherichia coli specifically binds a wheat gliadin peptide allowing the design of a new porous silicon-based optical biosensor. , 2006, Journal of proteome research.

[21]  Lifeng Kang,et al.  Microneedle integrated transdermal patch for fast onset and sustained delivery of lidocaine. , 2013, Molecular pharmaceutics.

[22]  N. Wilke,et al.  Process optimization and characterization of silicon microneedles fabricated by wet etch technology , 2005, Microelectron. J..

[23]  D. Barrow,et al.  Microfabricated silicon microneedles for nonviral cutaneous gene delivery , 2004, The British journal of dermatology.

[24]  M. Allen,et al.  Lack of Pain Associated with Microfabricated Microneedles , 2001, Anesthesia and analgesia.

[25]  M. Pishko,et al.  Release of protein from highly cross-linked hydrogels of poly(ethylene glycol) diacrylate fabricated by UV polymerization. , 2001, Biomaterials.

[26]  Ronen Polsky,et al.  Multiplexed microneedle-based biosensor array for characterization of metabolic acidosis. , 2012, Talanta.