Signal and resolution enhancements in dual beam optical coherence tomography of the human eye.

In the past 10 years, a dual beam version of partial coherence interferometry has been developed for measuring intraocular distances in vivo with a precision on the order of 0.3 to 3 μm. Two improvements of this technology are described. A special diffractive optical element allows matching of the wavefronts of the divergent beam reflected at the cornea and the parallel beam reflected at the retina and collimated by the optic system of the eye. In this way, the power of the light oscillations of the interfering beams incident on the photodetector is increased and the signal-to-noise ratio of in vivo measurements to the human retina is improved by 20 to 25 dB. By using a synthesized light source consisting of two spectrally displaced superluminescent diodes with an effective bandwidth of 50 nm, and by compensating for the dispersive effects of the ocular media, it was possible to record the first optical coherence tomogram of the retina of a human eye in vivo with an axial resolution of ∼6 to 7 μm. This is a twofold improvement over the current technology. © 1998 Society of Photo-Optical Instrumentation Engineers.

[1]  J. Duker,et al.  Imaging of macular diseases with optical coherence tomography. , 1995, Ophthalmology.

[2]  C K Hitzenberger,et al.  Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry. , 1998, Experimental eye research.

[3]  Wolfgang Drexler,et al.  Dispersion effects in partial coherence interferometry , 1997, Photonics West - Biomedical Optics.

[4]  Robert H. Webb,et al.  Scanning Laser Ophthalmoscope , 1981, IEEE Transactions on Biomedical Engineering.

[5]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[6]  D. Jackson,et al.  Coherence imaging by use of a Newton rings sampling function. , 1996, Optics letters.

[7]  B. Khoobehi,et al.  Feasibility test of a new method to measure retinal thickness noninvasively. , 1989, Investigative ophthalmology & visual science.

[8]  S Tane,et al.  [The study on the microscopic biometry of the thickness of the human retina, choroid and sclera by ultrasound]. , 1984, Nippon Ganka Gakkai zasshi.

[9]  S. Asrani,et al.  Application of rapid scanning retinal thickness analysis in retinal diseases. , 1997, Ophthalmology.

[10]  Wolfgang Drexler,et al.  Dual-beam optical coherence tomography and topography of the human eye: a clinical feasibility study , 1996, European Conference on Biomedical Optics.

[11]  Yunjiang Rao,et al.  Synthesized source for white-light sensing systems. , 1993, Optics letters.

[12]  Harald Sattmann,et al.  Measurement of the thickness of fundus layers by partial coherence tomography , 1995 .

[13]  C K Hitzenberger,et al.  Optical measurement of the axial eye length by laser Doppler interferometry. , 1991, Investigative ophthalmology & visual science.

[14]  Emil Wolf,et al.  CHAPTER X – INTERFERENCE AND DIFFRACTION WITH PARTIALLY COHERENT LIGHT , 1980 .

[15]  K Emi,et al.  [The biometry of each thickness of the human retina, choroid and sclera by using ultrasound and Fourier analysis--at the foveola]. , 1983, Nippon Ganka Gakkai zasshi.

[16]  L. Zangwill,et al.  Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. , 1995, American journal of ophthalmology.

[17]  A Sekine,et al.  Axial eye-length measurement by wavelength-shift interferometry. , 1993, Journal of the Optical Society of America. A, Optics and image science.

[18]  C K Hitzenberger,et al.  Mêasurement of corneal thickness by low-coherence interferometry. , 1992, Applied optics.

[19]  K Rohrschneider,et al.  Reproducibility of the optic nerve head topography with a new laser tomographic scanning device. , 1994, Ophthalmology.

[20]  J. Fujimoto,et al.  Optical coherence tomography of the human retina. , 1995, Archives of ophthalmology.

[21]  J G Fujimoto,et al.  High-resolution optical coherence tomographic imaging using a mode-locked Ti:Al(2)O(3) laser source. , 1995, Optics letters.

[22]  D. Jackson,et al.  Simultaneous en-face imaging of two layers in the human retina by low-coherence reflectometry. , 1997, Optics letters.

[23]  Wolfgang Drexler,et al.  Measurements of the posterior structures of the human eye in vivo by partial-coherence interferometry using diffractive optics , 1997, Photonics West - Biomedical Optics.

[24]  Harald Sattmann,et al.  Measurement of the anterior structures of the human eye by partial coherence interferometry , 1995, Other Conferences.

[25]  K. Grattan,et al.  A compact optical device for eye-length measurement , 1993, IEEE Photonics Technology Letters.

[26]  C K Hitzenberger,et al.  Submicrometer precision biometry of the anterior segment of the human eye. , 1997, Investigative ophthalmology & visual science.

[27]  A. W. Dreher,et al.  Retinal laser ellipsometry : a new method for measuring the retinal nerve fiber layer thickness distribution ? , 1992 .

[28]  Josef F. Bille,et al.  Scanning Laser Tomography of the Living Human Eye , 1990 .

[29]  Bo A. Moeller,et al.  Application of diffractive optics for axial eye-length measurement using partial coherence interferometry , 1996, European Conference on Biomedical Optics.

[30]  Y. N. Ning,et al.  Optimized multiwavelength combination sources for interferometric use. , 1994, Applied optics.

[31]  Xavier Clivaz,et al.  1.5-μm resolution optical low-coherence reflectometry in biological tissues , 1994, Other Conferences.

[32]  A. Fercher,et al.  In vivo optical coherence tomography. , 1993, American journal of ophthalmology.

[33]  R. Devenyi,et al.  Reproducibility of topographic measurements of the macula with a scanning laser ophthalmoscope. , 1995, Ophthalmology.

[34]  A. Fercher,et al.  Eye-length measurement by interferometry with partially coherent light. , 1988, Optics letters.

[35]  Adolf Friedrich Fercher,et al.  Ophthalmic Laser Interferometry , 1986, Other Conferences.