Accuracy and reproducibility of a novel dynamic volume flow measurement method.
暂无分享,去创建一个
Piero Tortoli | Magnus Cinthio | Asa Rydén Ahlgren | Stefano Ricci | P. Tortoli | Å. Ahlgren | S. Ricci | M. Cinthio | Å. R. Ahlgren
[1] Pascal Verdonck,et al. The Accuracy of Ultrasound Volume Flow Measurements in the Complex Flow Setting of a Forearm Vascular Access , 2013, The journal of vascular access.
[2] S. Ricci,et al. Adaptive spectral estimators for fast flow-profile detection , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[3] A. Dallai,et al. A reconfigurable and programmable FPGA-based system for nonstandard ultrasound methods , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[4] J Bercoff,et al. Ultrafast compound doppler imaging: providing full blood flow characterization , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[5] A. Redaelli,et al. Womersley number-based estimation of flow rate with Doppler ultrasound: Sensitivity analysis and first clinical application , 2010, Comput. Methods Programs Biomed..
[6] P. Tortoli,et al. An automatic angle tracking procedure for feasible vector Doppler blood velocity measurements. , 2010, Ultrasound in medicine & biology.
[7] P R Hoskins,et al. Haemodynamics and blood flow measured using ultrasound imaging , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[8] Oliver D Kripfgans,et al. Mean volume flow estimation in pulsatile flow conditions. , 2009, Ultrasound in medicine & biology.
[9] A. Dallai,et al. ULA-OP: an advanced open platform for ultrasound research , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[10] P. Tortoli,et al. Volumetric blood flow assessment through multigate spectral Doppler , 2009, 2009 IEEE International Ultrasonics Symposium.
[11] E. Bosboom,et al. Assessment of blood volume flow in slightly curved arteries from a single velocity profile. , 2009, Journal of biomechanics.
[12] S. Diciotti,et al. Accuracy and reproducibility of a novel dual-beam vector Doppler method. , 2009, Ultrasound in medicine & biology.
[13] Arnold P. G. Hoeks,et al. Model-based assessment of dynamic arterial blood volume flow from ultrasound measurements , 2009, Medical & Biological Engineering & Computing.
[14] Marcello Demi,et al. A System for Real-Time Measurement of the Brachial Artery Diameter in B-Mode Ultrasound Images , 2007, IEEE Transactions on Medical Imaging.
[15] P. Tortoli,et al. A programmable real-time system for development and test of new ultrasound investigation methods , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[16] K. Abend,et al. Validating volume flow measurements from a novel semiautomated four-dimensional Doppler ultrasound scanner. , 2006, Academic radiology.
[17] Richard S C Cobbold,et al. Human factors as a source of error in peak Doppler velocity measurement. , 2005, Journal of vascular surgery.
[18] P Tortoli,et al. Effect of vessel curvature on Doppler derived velocity profiles and fluid flow. , 2005, Ultrasound in medicine & biology.
[19] R. Cobbold,et al. Sample volume shape for pulsed-flow velocity estimation using a linear array. , 2004, Ultrasound in medicine & biology.
[20] Marcello Demi,et al. Real time contour tracking with a new edge detector , 2004, Real Time Imaging.
[21] Piero Tortoli,et al. Interaction between secondary velocities, flow pulsation and vessel morphology in the common carotid artery. , 2003, Ultrasound in medicine & biology.
[22] A. Hughes,et al. Reproducibility Study of Magnetic Resonance Image-Based Computational Fluid Dynamics Prediction of Carotid Bifurcation Flow , 2003, Annals of Biomedical Engineering.
[23] I. Krägeloh-Mann,et al. Measurement of volume of cerebral blood flow in healthy preterm and term neonates with ultrasound , 2002, The Lancet.
[24] Helena Gardiner,et al. Volume blood flow estimation in the normal and growth-restricted fetus. , 2002, Ultrasound in medicine & biology.
[25] S F Stewart,et al. Effects of transducer, velocity, Doppler angle, and instrument settings on the accuracy of color Doppler ultrasound. , 2001, Ultrasound in medicine & biology.
[26] P. Scheel,et al. Flow velocity and flow volume measurements in the extracranial carotid and vertebral arteries in healthy adults: reference data and the effects of age. , 2000, Ultrasound in medicine & biology.
[27] W. McDicken,et al. Doppler Ultrasound: Physics, Instrumentation and Signal Processing , 2000 .
[28] I. Puls,et al. Volume reduction in cerebral blood flow in patients with vascular dementia , 1999, The Lancet.
[29] K V Ramnarine,et al. Validation of a new blood-mimicking fluid for use in Doppler flow test objects. , 1998, Ultrasound in medicine & biology.
[30] P. Picot,et al. Quantitative volume flow estimation using velocity profiles , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[31] H. M. Payne,et al. Validation of A Doppler Guide Wire for Intravascular Measurement of Coronary Artery Flow Velocity , 1992, Circulation.
[32] T. Wada,et al. Correlation of common carotid flow volume measured by ultrasonic quantitative flowmeter with pathological findings. , 1991, Stroke.
[33] J. Womersley. Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known , 1955, The Journal of physiology.
[34] F. Massey. The Kolmogorov-Smirnov Test for Goodness of Fit , 1951 .
[35] E. Mendelson,et al. Schaum's outlines : calculus , 2009 .
[36] Kjell Lindström,et al. A computer-controlled arbitrary flow wave form generator for physiological studies , 2000 .