Performance investigation of a novel solar hybrid air conditioning and humidification–dehumidification water desalination system

Abstract Parametric and economic studies of the performance of a solar hybrid air conditioning (A/C) and humidification–dehumidification (HDH) water desalination system are presented. The system is integrated with thermal storage and auxiliary heating systems for steady-state operation. Fresh water production rate, fresh water recovery, cooling capacity, electrical power consumption, coefficient of performance and system economical index are studied at different operating and design parameters. The results show that (i) the electrical consumption of the auxiliary heater decreases with decreasing outdoor air flow rate and increasing both of outdoor air temperature, outdoor air humidity and temperature difference across the heating system, (ii) the increase in outdoor air temperature, outdoor humidity and temperature difference across the heating system increase the fresh water production and recovery rates, cooling capacity and the electric power consumption of the proposed system. Comparison with a basic air conditioning system showed that the proposed system has higher water production, cooling capacity, coefficient of performance (COP) and lower power/electricity consumptions at hot and humid regions. A cost analysis reveals that the saving in the total operating cost increases with increasing outdoor air temperature, and outdoor humidity and decreases with increasing temperature difference across the heating system.

[1]  V. V. Slesarenko Heat pumps as a source of heat energy for desalination of seawater , 2001 .

[2]  Ahmed A.A. Attia,et al.  New proposed system for freeze water desalination using auto reversed R-22 vapor compression heat pump. , 2010 .

[3]  Guofeng Yuan,et al.  Mathematical modeling of a closed circulation solar desalination unit with humidification-dehumidification , 2007 .

[4]  Adel M. Abdel Dayem,et al.  Experimental and numerical investigation of humidification/dehumidification solar water desalination systems , 2009 .

[5]  Ronan K. McGovern,et al.  Performance limits of zero and single extraction humidification-dehumidification desalination systems , 2012 .

[6]  Majid Amidpour,et al.  Constructal design and optimization of a direct contact humidification–dehumidification desalination unit , 2012 .

[7]  Mohammad Sadegh Hatamipour,et al.  Humidification compression desalination , 2014 .

[8]  A. E. Kabeel,et al.  A hybrid solar desalination system of air humidification dehumidification and water flashing evaporation: A comparison among different configurations , 2013 .

[9]  Guofeng Yuan,et al.  Experimental study on a humidification and dehumidification desalination system of solar air heater with evacuated tubes , 2014 .

[10]  F. A. Holland,et al.  Water desalination using heat pumps , 2000 .

[11]  Yogesh Jaluria,et al.  Design and Optimization of Thermal Systems , 1997 .

[12]  Penghui Gao,et al.  Performance analysis of a new type desalination unit of heat pump with humidification and dehumidification , 2008 .

[13]  İsmail Solmuş,et al.  A parametric study on a humidification–dehumidification (HDH) desalination unit powered by solar air and water heaters☆ , 2014 .

[14]  Hisham Ettouney,et al.  Analysis of single-effect evaporator desalination systems combined with vapor compression heat pumps , 1997 .

[15]  S. A. Nada,et al.  Experimental study for hybrid humidification–dehumidification water desalination and air conditioning system , 2015 .

[16]  A. E. Kabeel,et al.  Experimental study of a humidification-dehumidification solar technique by natural and forced air circulation , 2014 .

[17]  S. A. El-Agouz,et al.  A new process of desalination by air passing through seawater based on humidification–dehumidification process , 2010 .

[18]  Camilo A. Arancibia-Bulnes,et al.  Water desalination by air humidification: Mathematical model and experimental study , 2012 .

[19]  C. Chiranjeevi,et al.  Experimental and simulation studies on two stage humidification–dehumidification desalination and cooling plant , 2015 .

[20]  Badr Habeebullah Performance analysis of a combined heat pump-dehumidifying system. , 2010 .

[21]  D. A. Hindoliya,et al.  Experimental performance of new evaporative cooling pad materials , 2011 .

[22]  He Weifeng,et al.  A parametric study of a humidification dehumidification (HDH) desalination system using low grade heat sources , 2015 .

[23]  Adewale Giwa,et al.  Humidification–dehumidification desalination process driven by photovoltaic thermal energy recovery (PV-HDH) for small-scale sustainable water and power production , 2016 .

[24]  Ruzhu Wang,et al.  Parametric analysis to improve the performance of a solar desalination unit with humidification and dehumidification , 2002 .

[25]  S. A. Nada,et al.  Performance analysis of proposed hybrid air conditioning and humidification–dehumidification systems for energy saving and water production in hot and dry climatic regions , 2015 .

[26]  Huifang Kang,et al.  Performance of a two-stage multi-effect desalination system based on humidification–dehumidification process , 2014 .

[27]  W. Beckman,et al.  Solar Engineering of Thermal Processes , 1985 .

[28]  Hisham Ettouney,et al.  Low temperature humidification dehumidification desalination process , 2006 .

[29]  Guofeng Yuan,et al.  Experimental research of an integrative unit for air-conditioning and desalination , 2005 .