Preliminary synchronized phasor data analysis of disturbance events in the US Eastern Interconnection

This paper presents analysis results of synchronized phasor data from 10 disturbance events recorded in the US Eastern Interconnection (EI). The phasor data covers a wide region in the EI, allowing for the study of disturbance propagation, interarea modes, and oscillations in voltages and currents. The analysis is not straightforward because the EI is a meshed system with adequate interarea mode damping. Disturbances involving tripping a single large generator unit produce very short interarea swing responses. Islanding events involving regions at the perimeter, however, provide more prominent responses for analysis.

[1]  Kyung Soo Kook,et al.  Use of Frequency Oscillations to Improve Event Location Estimation in Power Systems , 2007, 2007 IEEE Power Engineering Society General Meeting.

[2]  Jeff Dagle North American SynchroPhasor Initiative , 2008, Proceedings of the 41st Annual Hawaii International Conference on System Sciences (HICSS 2008).

[3]  莊哲男 Applied System Identification , 1994 .

[4]  L. Dosiek,et al.  New algorithms for mode shape estimation using measured data , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[5]  Gordon Friedlander What went wrong VIII: The Great Blackout of '65: Could the `long night¿ happen again? What was learned from the dramatic six-state (plus Ontario) outage of November 9¿10, 1965? , 1976 .

[6]  J. F. Hauer,et al.  Keeping an eye on power system dynamics , 1997 .

[7]  Ieee Standards Board IEEE standard common format for transient data exchange (COMTRADE) for power systems , 1991 .

[8]  J. F. Hauer,et al.  Initial results in Prony analysis of power system response signals , 1990 .

[9]  Wei Li,et al.  Power system frequency oscillation characteristics , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[10]  Joe H. Chow,et al.  Power system disturbance identification from recorded dynamic data at the Northfield substation , 2003 .

[11]  G. D. Friedlander The Great Blackout of '65 , 1976, IEEE Spectrum.

[12]  A.G. Phadke,et al.  The Wide World of Wide-area Measurement , 2008, IEEE Power and Energy Magazine.

[13]  J. Hauer,et al.  Emergence of a New Swing Mode in the Western Power System , 1981, IEEE Transactions on Power Apparatus and Systems.

[14]  James S. Thorp,et al.  Continuum modeling of electromechanical dynamics in large-scale power systems , 2004, IEEE Transactions on Circuits and Systems I: Regular Papers.

[15]  J. H. Chow,et al.  Computation of power system low-order models from time domain simulations using a Hankel matrix , 1997 .

[16]  D. N. Ewart Power: Whys and wherefores of power system blackouts: An examination of the factors that increase the likelihood and the frequency of system failure , 1978, IEEE Spectrum.