Chiral separation of amino acids by ligand‐exchange capillary electrochromatography using continuous beds

A chiral ligand‐exchange phase for capillary electrochromatography based on continuous bed technology was developed. The chiral stationary phase is prepared by a one‐step in situ copolymerization procedure using methacrylamide, piperazine diacrylamide, vinylsulfonic acid and N‐(2‐hydroxy‐3‐allyloxypropyl)‐L‐4‐hydroxyproline. These chiral continuous beds are inexpensive and easy to prepare. They also have several advantages over silica‐based packed capillaries. Since the bed is covalently attached to the capillary wall, no frit is required. The applicability of this new approach to the chiral separation of underivatized amino acids is demonstrated.

[1]  P. Sandra,et al.  Applications of capillary electrochromatography , 1999, Electrophoresis.

[2]  R. Rinaldi,et al.  Enantioseparation of α-amino acids and dipeptides by ligand-exchange capillary electrophoresis of various l-4-hydroxyproline derivatives , 1999 .

[3]  Á. Végvári,et al.  (Normal-Phase) Capillary Chromatography Using Acrylic Polymer-Based Continuous Beds , 1999 .

[4]  Á. Végvári,et al.  Chiral separation of α‐amino acids by ligand‐exchange capillary electrophoresis using N‐(2‐hydroxy‐octyl)‐L‐4‐hydroxyproline as a selector , 1998 .

[5]  L. Andersson,et al.  Molecular imprint-based stationary phases for capillary electrochromatography , 1998 .

[6]  V. Schurig,et al.  Enantiomer separation by pressure-supported electrochromatography using capillaries packed with a permethyl-β-cyclodextrin stationary phase , 1998 .

[7]  K. Uchiyama,et al.  Enantiomeric resolution of dansyl amino acids by capillary electrochromatography based on molecular imprinting method , 1998 .

[8]  M. Juza,et al.  Dual chiral recognition system involving cyclodextrin derivatives in capillary electrophoresis II. Enhancement of enantioselectivity , 1998, Electrophoresis.

[9]  S. Hjertén,et al.  Preparation of continuous beds for electrochromatography and reversed-phase liquid chromatography of low-molecular-mass compounds , 1997 .

[10]  S. Hjertén,et al.  Continuous beds for microchromatography: reversed-phase chromatography. , 1996, Analytical Biochemistry.

[11]  S. Hjertén,et al.  Dye-ligand affinity chromatography on continuous beds. , 1995, Biomedical chromatography : BMC.

[12]  L. Terenius,et al.  Continuous beds for microchromatography: cation-exchange chromatography. , 1994, Analytical biochemistry.

[13]  S. Hjertén,et al.  Reversed-phase chromatography of proteins and peptides on compressed continuous beds , 1993 .

[14]  V. Schurig,et al.  Enantiomer separation by electrochromatography in open tubular columns coated with chirasil-dex , 1993 .

[15]  S. Hjertén,et al.  Continuous beds for standard and micro high-performance liquid chromatography , 1991 .

[16]  G. Gübitz,et al.  Direct separation of amino enantiomers by high performance ligand exchange chromatography on chemically bonded chiral phases , 1982 .

[17]  G. Gübitz,et al.  Separation of the optical isomers of amino acids by ligand-exchange chromatography using chemically bonded chiral phases , 1981 .

[18]  M. Schmid,et al.  Chiral separation by capillary electrochromatography. , 2000, Enantiomer.

[19]  V. Schurig,et al.  Enantiomer separation using mobile and immobile cyclodextrin derivatives with electromigration , 1994, Electrophoresis.

[20]  S. Hjertén,et al.  A new type of pH‐ and detergent‐stable coating for elimination of electroendosmosis and adsorption in (capillary) electrophoresis , 1993, Electrophoresis.

[21]  K. Nakazato,et al.  Chiral-recognition chromatography of β-blockers on continuous polymer beds with immobilized cellulase as enantioselective protein , 1993 .

[22]  S. Hjertén,et al.  High-performance chromatofocusing of proteins on compressed continuous beds with improved properties , 1992 .

[23]  S. Hjertén,et al.  High-performance liquid chromatography on continuous polymer beds , 1989 .

[24]  V. Davankov,et al.  Ligand exchange chromatography , 1988 .

[25]  S. Rogozhin,et al.  Ligand chromatography as a novel method for the investigation of mixed complexes: stereoselective effects in -amino acid copper (II) complexes. , 1971, Journal of chromatography.