Improved beamforming using curved sparse 2D arrays in ultrasound.

In this work we have investigated the effect of curving phase-steered sparse periodic two-dimensional arrays in one direction, and relate this effect to the geometry of the arrays. We have shown that curving is equivalent to removing some of the element periodicity, thus adding some "randomness" to the layout. Compared to flat phase-steered periodically sparse two-dimensional arrays, curving offers an even greater suppression of grating lobes located at directions along the curvature. The class of arrays yielding improved performance due to this suppression of grating lobes has been characterized. The point spread functions of some previously proposed array layouts, shown to be promising for ultrasonic imaging, have been simulated. The arrays have been simulated with various number of elements as well as various focal points, with array and field parameters typical to those in volumetric cardiac imaging. On a 48 x 48 element grid with a transducer center frequency of 3 MHz and the target at 40 mm, reductions in the peak sidelobe level of up to 12dB were recorded for some critical steering directions, without significant differences in the beamwidth. The integrated sidelobe ratio was also examined, showing an almost equivalent performance as the flat array. This study shows that, without adding any complexity to the system, the overall image quality of a volumetric imaging system can be improved significantly by curving the array in one direction.

[1]  Fan Wang,et al.  Optimal array pattern synthesis using semidefinite programming , 2003, IEEE Trans. Signal Process..

[2]  Jae S. Lim,et al.  Two-Dimensional Signal and Image Processing , 1989 .

[3]  A. Trucco Weighting and thinning wide-band arrays by simulated annealing. , 2002, Ultrasonics.

[4]  Sergio Barbarossa,et al.  Optimal configuration and weighting of nonuniform arrays according to a maximum ISLR criterion , 1994, Proceedings of ICASSP '94. IEEE International Conference on Acoustics, Speech and Signal Processing.

[5]  S. Holm,et al.  Curved two-dimensional arrays in ultrasound , 2004, IEEE Ultrasonics Symposium, 2004.

[6]  Tsung O Cheng,et al.  Real-time 3-dimensional echocardiography: a review of the development of the technology and its clinical application. , 2005, Progress in cardiovascular diseases.

[7]  D.H. Turnbull,et al.  Beam steering with pulsed two-dimensional transducer arrays , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  W. A. Smith,et al.  The role of piezocomposites in ultrasonic transducers , 1989, Proceedings., IEEE Ultrasonics Symposium,.

[9]  J A Jensen,et al.  Application of different spatial sampling patterns for sparse array transducer design. , 2000, Ultrasonics.

[10]  Jørgen Jensen,et al.  Simulation of advanced ultrasound systems using Field II , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).

[11]  F.S. Foster,et al.  Optimizing the radiation pattern of sparse periodic two-dimensional arrays , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Michael C. Hill,et al.  Ultrasound Annual, 1985 , 1985 .

[13]  S. Holm,et al.  Properties of the beampattern of weight- and layout-optimized sparse arrays , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  S.W. Smith,et al.  Sparse 2-D array design for real time rectilinear volumetric imaging , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  A. Trucco,et al.  Thinning and weighting of large planar arrays by simulated annealing , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  R. M. Schmitt,et al.  Optimization of random sparse 2-D transducer arrays for 3-D electronic beam steering and focusing , 1994, 1994 Proceedings of IEEE Ultrasonics Symposium.

[17]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  C.L. Dolph,et al.  A Current Distribution for Broadside Arrays Which Optimizes the Relationship between Beam Width and Side-Lobe Level , 1946, Proceedings of the IRE.

[19]  Pai-Chi Li,et al.  Optimizing the radiation pattern of sparse periodic linear arrays , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  O. Oralkan,et al.  Volumetric ultrasound imaging using 2-D CMUT arrays , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  A. Austeng,et al.  Sparse 2-D arrays for 3-D phased array imaging - design methods , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Sverre Holm,et al.  1D and 2D algorithmically optimized sparse arrays , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[23]  S W Smith,et al.  Real-Time Cylindrical Curvilinear 3-D Ultrasound Imaging , 2003, Ultrasonic imaging.

[24]  Stephen W. Smith,et al.  Beam Steering with Linear Arrays , 1983, IEEE Transactions on Biomedical Engineering.

[26]  Sverre Holm Minimum sidelobe energy versus minimum peak sidelobe level for sparse array optimization , 1996 .

[27]  W. Steichen,et al.  A two-dimensional transducer array for real-time 3D medical ultrasound imaging , 1998, 1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102).

[28]  M. O'Donnell,et al.  Microwave-Induced Thermal Imaging of Tissue Dielectric Properties , 2003, Ultrasonic imaging.