Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants

Inductively coupled coil pair is the most common way of wirelessly transferring power to medical implants. However, the coil displacements and/or loading changes may induce large fluctuations in transmitted power into the implant if no adaptive control is used. In such cases, it is required to transmit excessive power to accommodate all the working conditions, which substantially reduces the power efficiency and imposes potential safety concerns. We have implemented a power transfer system with adaptive control technique to eliminate the power variations due to the loading or coupling coefficient changes. A maximum of 250mW power is transmitted through an optimized coil pair driven by Class-E power amplifier. Load shift keying is implemented to wirelessly transfer data back from the secondary to primary side over the same coil pair, with data rate of 3.3 kbps and packet error rate less than 10/sup -5/. A pseudo pulsewidth modulation has been designed to facilitate back data transmission along with forward power transmission. Through this back telemetry the system transmits the information on received power, back from implant to primary side. According to the data received, the system adjusts the supply voltage of the Class-E power amplifier through a digitally controlled dc-dc converter, thus varying the power sent to the implant. The key system parameters are optimized to ensure the stability of the closed-loop system. Measurements show that the system can transmit the 'just-needed' power for a wide range of coil separation and/or loading conditions, with power efficiency doubled when compared to the uncompensated link.

[1]  K. Najafi,et al.  A single-channel implantable microstimulator for functional neuromuscular stimulation , 1997, IEEE Transactions on Biomedical Engineering.

[2]  Wentai Liu,et al.  A closed loop transcutaneous power transfer system for implantable devices with enhanced stability , 2004, 2004 IEEE International Symposium on Circuits and Systems (IEEE Cat. No.04CH37512).

[3]  P. H. Peckham,et al.  Data transmission from an implantable biotelemeter by load-shift keying using circuit configuration modulator , 1995 .

[4]  Wentai Liu,et al.  An efficient inductive power link design for retinal prosthesis , 2004, 2004 IEEE International Symposium on Circuits and Systems (IEEE Cat. No.04CH37512).

[5]  B.H. Cho,et al.  Design of a transcutaneous energy transmission system using a series resonant converter , 1990, 21st Annual IEEE Conference on Power Electronics Specialists.

[6]  Zhengnian Tang,et al.  Multichannel implantable stimulation and telemetry system for neuromuscular control , 1994, Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  W. Liu,et al.  A neuro-stimulus chip with telemetry unit for retinal prosthetic device , 2000, IEEE Journal of Solid-State Circuits.

[8]  W.J. Heetderks,et al.  RF powering of millimeter- and submillimeter-sized neural prosthetic implants , 1988, IEEE Transactions on Biomedical Engineering.

[9]  Hugh J. McDermott,et al.  An advanced multiple channel cochlear implant , 1989, IEEE Transactions on Biomedical Engineering.

[10]  Wentai Liu,et al.  A smart bi-directional telemetry unit for retinal prosthetic device , 2003, Proceedings of the 2003 International Symposium on Circuits and Systems, 2003. ISCAS '03..

[11]  Ma Lin,et al.  A deductive method for antenna near-field computation in EMC prediction , 2004, Proceedings. ICCEA 2004. 2004 3rd International Conference on Computational Electromagnetics and Its Applications, 2004..

[12]  Tayfun Akin,et al.  A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode , 1998, IEEE J. Solid State Circuits.

[13]  Frederick H. Raab,et al.  Idealized operation of the class E tuned power amplifier , 1977 .

[14]  Kyusun Choi,et al.  Fat tree encoder design for ultra-high speed flash A/D converters , 2002, The 2002 45th Midwest Symposium on Circuits and Systems, 2002. MWSCAS-2002..

[15]  P.R. Troyk,et al.  Closed-loop class E transcutaneous power and data link for MicroImplants , 1992, IEEE Transactions on Biomedical Engineering.

[16]  No Sokal,et al.  CLASS-E - NEW CLASS OF HIGH-EFFICIENCY TUNED SINGLE-ENDED SWITCHING POWER AMPLIFIERS , 1975 .

[17]  Wentai Liu,et al.  An optimal design methodology for inductive power link with class-E amplifier , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.