Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) Imaging for the Diagnosis of Cirrhosis during Liver Ultrasonography

PURPOSE VirtualTouch is a new technique recently proposed to evaluate liver stiffness during B-mode ultrasonography. The goal of the present study was to analyze the diagnostic accuracy of VirtualTouch in the diagnosis of cirrhosis and its correlation with transient elastography (Fibroscan). MATERIALS AND METHODS A total of 133 patients with chronic liver disease were enrolled. 90 of 133 underwent VirtualTouch and transient elastography and 70 patients assessed with VirtualTouch were submitted to liver biopsy. Stiffness was assessed by both techniques in the right liver lobe. The diagnostic accuracy for cirrhosis was first assessed in the 90 patients submitted to transient elastography with > 13 kPa (47 % of patients) as diagnostic for cirrhosis values. The best cut-off for cirrhosis with VirtualTouch was then tested in the 70 patients with biopsy (cirrhosis in 38 % of patients). 41 patients were assessed by VirtualTouch by two different operators. RESULTS The VirtualTouch values in controls, chronic hepatitis and cirrhosis were respectively 113, 147 and 255 cm/sec. The AUROC of liver VirtualTouch for the diagnosis of cirrhosis (reference Fibroscan) was 0.941 with 175 cm/sec as the best cut-off (sensitivity 93.0 %; specificity 85.1 %). VirtualTouch confirmed good performance also in patients with bioptic diagnosis of cirrhosis (AUROC 0.908, sensitivity 81.5 %, specificity 88.4 %,). The correlation of VirtualTouch with transient elastography was strict (r = 0.891) and the correlation in VirtualTouch measurements between two operators was also good (r = 0.874). CONCLUSION VirtualTouch is able to identify the presence of cirrhosis with good accuracy, shows good interobserver reproducibility and the correlation of its values with those obtained by transient elastography with Fibroscan is good.

[1]  D. Conte,et al.  Severe liver fibrosis or cirrhosis: accuracy of US for detection--analysis of 300 cases. , 2003, Radiology.

[2]  P. Schirmacher,et al.  Real-time tissue elastography versus FibroScan for noninvasive assessment of liver fibrosis in chronic liver disease. , 2009, Ultraschall in der Medizin.

[3]  Gabriela Marinoschi,et al.  Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis. , 2009, World journal of gastroenterology.

[4]  V. de Lédinghen,et al.  Prevalence and factors associated with failure of liver stiffness measurement using FibroScan in a prospective study of 2114 examinations , 2006, European journal of gastroenterology & hepatology.

[5]  R. Goertz,et al.  Measurement of Liver Elasticity with Acoustic Radiation Force Impulse (ARFI) Technology: An Alternative Noninvasive Method for Staging Liver Fibrosis in Viral Hepatitis , 2010, Ultraschall in der Medizin.

[6]  E. Schiff,et al.  Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection , 2002, American Journal of Gastroenterology.

[7]  S. Milani,et al.  Reliability of transient elastography for the diagnosis of advanced fibrosis in chronic hepatitis C , 2008, Gut.

[8]  M. Ziol,et al.  Transient elastography: a new noninvasive method for assessment of hepatic fibrosis. , 2003, Ultrasound in medicine & biology.

[9]  Steven Solga,et al.  Can imaging modalities diagnose and stage hepatic fibrosis and cirrhosis accurately? , 2009, Journal of hepatology.

[10]  Eva Herrmann,et al.  Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography. , 2009, Radiology.

[11]  Roger W Nightingale,et al.  An Integrated Indenter-ARFI Imaging System for Tissue Stiffness Quantification , 2008, Ultrasonic imaging.

[12]  V. Agrawal,et al.  A parallel tracking method for acoustic radiation force impulse imaging , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  Eva Herrmann,et al.  Performance of transient elastography for the staging of liver fibrosis: a meta-analysis. , 2008, Gastroenterology.

[14]  K. Nightingale,et al.  Quantifying hepatic shear modulus in vivo using acoustic radiation force. , 2008, Ultrasound in medicine & biology.

[15]  Hirokazu Takahashi,et al.  Evaluation of acoustic radiation force impulse elastography for fibrosis staging of chronic liver disease: a pilot study , 2010, Liver international : official journal of the International Association for the Study of the Liver.

[16]  Gregg Trahey,et al.  Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility. , 2002, Ultrasound in medicine & biology.

[17]  V. Paradis,et al.  Sampling variability of liver fibrosis in chronic hepatitis C , 2003, Hepatology.

[18]  I. Sporea,et al.  Acoustic Radiation Force Impulse Elastography as Compared to Transient Elastography and Liver Biopsy in Patients with Chronic Hepatopathies , 2010, Ultraschall in der Medizin.

[19]  P. Monari,et al.  The microvascular architecture of spleen in congestive splenomegaly. A morphological-histometric study. , 1982, Pathology, research and practice.

[20]  P. Andreone,et al.  Assessment of liver fibrosis in transplant recipients with recurrent HCV infection: usefulness of transient elastography. , 2009, Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver.

[21]  Radu Badea,et al.  Performance of a new elastographic method (ARFI technology) compared to unidimensional transient elastography in the noninvasive assessment of chronic hepatitis C. Preliminary results. , 2009, Journal of gastrointestinal and liver diseases : JGLD.

[22]  Dario Conte,et al.  Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver disease , 2007, Gut.

[23]  R. Sacco,et al.  Transient elastography: a new surrogate marker of liver fibrosis influenced by major changes of transaminases , 2007, Journal of viral hepatitis.