Ultrafast Fabry-Perot fiber-optic pressure sensors for multimedia blast event measurements.

A shock wave (SW) is characterized as a large pressure fluctuation that typically lasts only a few milliseconds. On the battlefield, SWs pose a serious threat to soldiers who are exposed to explosions, which may lead to blast-induced traumatic brain injuries. SWs can also be used beneficially and have been applied to a variety of medical treatments due to their unique interaction with tissues and cells. Consequently, it is important to have sensors that can quantify SW dynamics in order to better understand the physical interaction between body tissue and the incident acoustic wave. In this paper, the ultrafast fiber-optic sensor based on the Fabry-Perot interferometric principle was designed and four such sensors were fabricated to quantify a blast event within different media, simultaneously. The compact design of the fiber-optic sensor allows for a high degree of spatial resolution when capturing the wavefront of the traveling SW. Several blast event experiments were conducted within different media (e.g., air, rubber membrane, and water) to evaluate the sensor's performance. This research revealed valuable knowledge for further study of SW behavior and SW-related applications.

[1]  Christopher Niezrecki,et al.  An ultra-fast fiber optic pressure sensor for blast event measurements , 2012 .

[2]  Camelia Dunare,et al.  Design and fabrication of dielectric diaphragm pressure sensors for applications to shock wave measurement in air , 2007 .

[3]  Kazuyoshi Takayama,et al.  Mechanisms of primary blast-induced traumatic brain injury: insights from shock-wave research. , 2011, Journal of neurotrauma.

[4]  Julian D. C. Jones,et al.  Blast-pressure measurement with a high-bandwidth fibre optic pressure sensor , 2000 .

[5]  Christopher Niezrecki,et al.  Study of blast event propagation in different media using a novel ultrafast miniature optical pressure sensor , 2011, Defense + Commercial Sensing.

[6]  Julian D. C. Jones,et al.  Investigation of shock waves in explosive blasts using fibre optic pressure sensors , 2005 .

[7]  James H. Smith,et al.  Micromachined pressure sensors: review and recent developments , 1997, Smart Structures.

[8]  K. Takayama,et al.  Application of extracorporeal shock wave on bone: preliminary report. , 1999, The Journal of trauma.

[9]  Kobi Peleg,et al.  Blast injuries. , 2005, The New England journal of medicine.

[10]  M. Delius Medical applications and bioeffects of extracorporeal shock waves , 1994 .

[11]  E. Schmiedt,et al.  EXTRACORPOREALLY INDUCED DESTRUCTION OF KIDNEY STONES BY SHOCK WAVES , 1980, The Lancet.

[12]  C. Niezrecki,et al.  Optical pressure/acoustic sensor with precise Fabry-Perot cavity length control using angle polished fiber. , 2009, Optics express.

[13]  S. Okie Traumatic brain injury in the war zone. , 2005, The New England journal of medicine.

[14]  Xiaotian Zou,et al.  An experimental study on the concrete hydration process using Fabry–Perot fiber optic temperature sensors , 2012 .

[15]  Explosions and Blast Injuries : A Primer for Clinicians , 2006 .

[16]  S. Liang,et al.  Numerical Simulation of Blast-Wave Propagation in a Small Two-Medium Duct , 2009 .

[17]  Michael A. Maffeo,et al.  Low-cost rapid miniature optical pressure sensors for blast wave measurements. , 2011, Optics express.

[18]  Michael J. Hodgson,et al.  CURRENT CONCEPTS blast injuries , 2005 .

[19]  S. Ridah,et al.  Shock waves in water , 1988 .

[20]  Christopher Niezrecki,et al.  Rapid miniature fiber optic pressure sensors for blast wave measurements , 2013 .