Predictors of severe tricuspid regurgitation in patients with permanent pacemaker or automatic implantable cardioverter-defibrillator leads.

Patients with permanent pacemaker or automatic implantable cardioverter-defibrillator (AICD) leads have an increased prevalence of tricuspid regurgitation. However, the roles of cardiac rhythm and lead-placement duration in the development of severe tricuspid regurgitation are unclear. We reviewed echocardiographic data on 26 consecutive patients who had severe tricuspid regurgitation after permanent pacemaker or AICD placement; before treatment, they had no organic tricuspid valve disease, pulmonary hypertension, left ventricular dysfunction, or severe tricuspid regurgitation. We compared the results to those of 26 control subjects who had these same devices but no more than mild tricuspid regurgitation. The patients and control subjects were similar in age (mean, 81 ±6 vs 81 ±8 yr; P = 0.83), sex (male, 42% vs 46%; P = 0.78), and left ventricular ejection fraction (0.60 ±0.06 vs 0.58 ± 0.05; P = 0.4). The patients had a higher prevalence of atrial fibrillation (92% vs 65%; P=0.01) and longer median duration of pacemaker or AICD lead placement (49.5 vs 5 mo; P < 0.001). After adjusting for age, sex, and right ventricular systolic pressure by multivariate logistic regression analysis, we found that atrial fibrillation (odds ratio=6.4; P = 0.03) and duration of lead placement (odds ratio=1.5/yr; P = 0.001) were independently associated with severe tricuspid regurgitation. Out study shows that atrial fibrillation and longer durations of lead placement might increase the risk of severe tricuspid regurgitation in patients with permanent pacemakers or AICDs.

[1]  S. Solomon,et al.  GUIDELINES AND STANDARDS , 2010 .

[2]  S. Vittala,et al.  Predictors for the Development of Severe Tricuspid Regurgitation with Anatomically Normal Valve in Patients with Atrial Fibrillation , 2012, Echocardiography.

[3]  A. Lahad,et al.  Tricuspid Incompetence Following Permanent Pacemaker Implantation , 2009, Pacing and clinical electrophysiology : PACE.

[4]  A. Shiran,et al.  Tricuspid regurgitation in mitral valve disease incidence, prognostic implications, mechanism, and management. , 2009, Journal of the American College of Cardiology.

[5]  Jonathan Lessick,et al.  Functional tricuspid regurgitation in patients with pulmonary hypertension: is pulmonary artery pressure the only determinant of regurgitation severity? , 2009, Chest.

[6]  D. Spevack,et al.  The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: an observational study. , 2008, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[7]  J. Lessick,et al.  Echocardiography-based spectrum of severe tricuspid regurgitation: the frequency of apparently idiopathic tricuspid regurgitation. , 2007, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[8]  Richard B Devereux,et al.  Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardio , 2005, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[9]  T. Sundt,et al.  Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads. , 2005, Journal of the American College of Cardiology.

[10]  M. Stefadouros,et al.  Regression of significant tricuspid regurgitation after mitral balloon valvotomy for severe mitral stenosis. , 2004, American heart journal.

[11]  Jayant Nath,et al.  Impact of tricuspid regurgitation on long-term survival. , 2004, Journal of the American College of Cardiology.

[12]  S. Yoshifuku,et al.  Impact of atrial fibrillation on tricuspid and mitral annular dilatation and valvular regurgitation. , 2002, Circulation journal : official journal of the Japanese Circulation Society.

[13]  S. Rosenheck,et al.  Transvenous Pacemaker Leads Do Not Worsen Tricuspid Regurgitation: A Prospective Echocardiographic Study , 2000, Cardiology.

[14]  C. Cock,et al.  Long‐Term Outcome of Patients with Multiple (≥ 3) Noninfected Transvenous Leads: A Clinical and Echocardiographic Study , 2000 .

[15]  G. Lamas,et al.  Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemaker leads , 1996 .

[16]  S. Ohkawa,et al.  [Tricuspid regurgitation induced by transvenous right ventricular pacing: echocardiographic and pathological observations]. , 1987, Journal of cardiology.