Dense and sparse 2-D array radiation patterns in lossy media

Two-dimensional (2-D) transducer arrays are potentially able to generate real-time volumetric images of internal organs of the human body, and much work has been done on the subject in recent years. A 2-D array with high resolution and low grating lobe level requires a prohibitively large number of elements for existing technology. A successful solution to reduce the number of elements, without sacrificing the above mentioned characteristics, is to select a limited number of elements in a random way or combining transmitting and receiving apertures with element spacing greater than one-half of a wavelength. In this work, the effect of the human body attenuation on the performances of these so-called sparse arrays is investigated. We analytically demonstrate that, for continuous wave excitation and under paraxial approximation, the medium losses can be modeled as a Gaussian weighting function, acting off-axis in the observation plane. The variance of this weighting function decreases with the covered distance. Radiation patterns computed with both this simple model and with a more exact expression, are presented for sparse and dense 2-D arrays under continuous and pulsed wave operation. Comparisons between the results obtained with and without attenuation also are shown.

[1]  J. Goodman Introduction to Fourier optics , 1969 .

[2]  G.R. Lockwood,et al.  Broad-bandwidth radiation patterns of sparse two-dimensional vernier arrays , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Sverre Holm,et al.  An approach to the design of sparse array systems , 1994, 1994 Proceedings of IEEE Ultrasonics Symposium.

[4]  K V Gurumurthy,et al.  A dispersive model for the propagation of ultrasound in soft tissue. , 1982, Ultrasonic imaging.

[5]  Sverre Holm,et al.  Optimization of the beampattern of 2D sparse arrays by weighting , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.

[6]  J. Jensen Estimation of Blood Velocities Using Ultrasound: A Signal Processing Approach , 1996 .

[7]  D.H. Turnbull,et al.  Beam steering with pulsed two-dimensional transducer arrays , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  S.W. Smith,et al.  Two-Dimensional Arrays for Medical Ultrasound , 1991, IEEE 1991 Ultrasonics Symposium,.

[9]  R. Leahy,et al.  On the design of maximally sparse beamforming arrays , 1991 .

[10]  F.S. Foster,et al.  Optimizing the radiation pattern of sparse periodic two-dimensional arrays , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  R. Ludwig,et al.  An explicit numerical time domain formulation to simulate pulsed pressure waves in viscous fluids exhibiting arbitrary frequency power law attenuation , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Lawrence E. Kinsler,et al.  Fundamentals of acoustics , 1950 .

[13]  J. Greenleaf,et al.  A study of two-dimensional array transducers for limited diffraction beams , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  R. E. Davidsen,et al.  Two-Dimensional Random Arrays for Real Time Volumetric Imaging , 1994 .

[15]  Jørgen Arendt Jensen,et al.  Ultrasound fields in an attenuating medium , 1993 .

[16]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  R. M. Schmitt,et al.  Optimization of random sparse 2-D transducer arrays for 3-D electronic beam steering and focusing , 1994, 1994 Proceedings of IEEE Ultrasonics Symposium.

[18]  R Lerch,et al.  Ultrasound fields in attenuating media. , 1986, The Journal of the Acoustical Society of America.

[19]  G. R. Lockwood,et al.  Optimizing sparse two-dimensional transducer arrays using an effective aperture approach , 1994, 1994 Proceedings of IEEE Ultrasonics Symposium.

[20]  Thomas L. Szabo,et al.  Causal theories and data for acoustic attenuation obeying a frequency power law , 1995 .

[21]  O. T. von Ramm,et al.  Gray Scale Imaging With Complex TGC And Transducer Arrays , 1976, Other Conferences.

[22]  S. Holm,et al.  Properties of the beampattern of weight- and layout-optimized sparse arrays , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  R. E. Davidsen,et al.  Sparse geometries for two-dimensional array transducers in volumetric imaging , 1993 .

[24]  Pai-Chi Li,et al.  Optimizing the radiation pattern of sparse periodic linear arrays , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  Daniel H. Turnbull,et al.  Simulation of B-scan images from two-dimensional transducer arrays , 1990, IEEE Symposium on Ultrasonics.

[26]  Thomas L. Szabo,et al.  Time domain wave equations for lossy media obeying a frequency power law , 1994 .