Biosensing under an applied voltage using optical waveguide lightmode spectroscopy.

An applied dc voltage offers a means of controlling immobilization during biosensor fabrication and detection during biosensing application. We present a method to directly and continuously measure the adsorption of biomacromolecules or other polyelectrolytes, under an applied potential difference, based on optical waveguide lightmode spectroscopy (OWLS). An indium tin oxide (ITO) film of thickness ca. 10 nm coated onto a silicon titanium oxide (STO) waveguiding film serves as the working (sensing) electrode. We observe the effective refractive index of the 0th transverse electric guided mode to increase significantly in the presence of an applied potential due to charging of the interfacial double layer and, possibly, modest electrochemical oxidation. Adsorption from solution onto the ITO electrode is detected by a further increase in the effective refractive index. We achieve accurate detection by employing an optical model in which the STO and ITO layers are combined into a single waveguiding film. No improvement is found using models treating the ITO as a separate layer, either dielectric or conducting. Using this method, we find the adsorption of human serum albumin and horse heart cytochrome c to be considerably enhanced in the presence of an applied potential exceeding 1 V. We attribute this behavior to adsorption at positions on the protein molecules of complementary charge.

[1]  C. Calonder,et al.  History dependence of protein adsorption kinetics , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[2]  M. C. Stuart,et al.  Electro-optic effect in the solid phase of the indium tin oxide/electrolyte solution interface observed by reflectometry , 1996 .

[3]  Wilson,et al.  Heteroenergetics of Bovine Serum Albumin Adsorption from Good Solvents Related to Crystallization Conditions , 1997, Journal of colloid and interface science.

[4]  J. Ramsden OWLS: A Versatile Technique for Sensing with Bioarrays , 1999, CHIMIA.

[5]  J. Ramsden Review of new experimental techniques for investigating random sequential adsorption , 1993 .

[6]  F. Veer,et al.  Ellipsometry as a tool to study the adsorption behavior of synthetic and biopolymers at the air–water interface , 1978 .

[7]  Z. Liron,et al.  Voltage-induced inhibition of antigen-antibody binding at conducting optical waveguides. , 2002, Biosensors & bioelectronics.

[8]  W. Lukosz,et al.  Integrated optical chemical and direct biochemical sensors , 1995 .

[9]  H. Takenouti,et al.  Long-time and short-time investigation of the electrode interface through electrochemical impedance measurements. Application to adsorption of human serum albumin onto glassy carbon rotating disc electrode , 1997 .

[10]  J. Ramsden,et al.  Voltage-dependent coupling of light into ITO-covered waveguides , 2002 .

[11]  J. Anzai,et al.  Adsorption behavior of serum albumin on electrode surfaces and the effects of electrode potential. , 1996, Chemical & pharmaceutical bulletin.

[12]  S. Omanovic,et al.  Electrochemical Studies of the Effect of Temperature on the Adsorption of Yeast Alcohol Dehydrogenase at Pt , 2001 .

[13]  M. van der Graaf,et al.  Orientation of adsorbed cytochrome c as a function of the electrical potential of the interface studied by total internal reflection fluorescence. , 1990, Biophysical journal.

[14]  J. Andrade,et al.  Protein adsorption on low temperature isotropic carbon: V. How is it related to its blood compatibility? , 1995, Journal of biomaterials science. Polymer edition.

[15]  V. Macagno,et al.  Study of human serum albumin-TiO(2) nanocrystalline electrodes interaction by impedance electrochemical spectroscopy. , 2001, Biophysical chemistry.

[16]  A. Asanov,et al.  Regenerable biosensor platform: a total internal reflection fluorescence cell with electrochemical control. , 1998, Analytical chemistry.

[17]  P. Schaaf,et al.  Determination of structural parameters characterizing thin films by optical methods: A comparison between scanning angle reflectometry and optical waveguide lightmode spectroscopy , 2001 .

[18]  W. Lukosz,et al.  Integrated optical input grating couplers as direct affinity sensors , 1993 .

[19]  W. Norde,et al.  INFLUENCE OF THE ELECTRIC POTENTIAL OF THE INTERFACE ON THE ADSORPTION OF PROTEINS , 1994 .

[20]  Michelle A. Brusatori,et al.  Protein Adsorption Kinetics under an Applied Electric Field: An Optical Waveguide Lightmode Spectroscopy Study , 2003 .

[21]  J. Ramsden Porosity of pyrolysed sol–gel waveguides , 1994 .

[22]  P. R. V. Tassel,et al.  Kinetic Regimes of Protein Adsorption , 2001 .

[23]  M. Textor,et al.  Optical grating coupler biosensors. , 2002, Biomaterials.

[24]  W. Wernet,et al.  Adsorption of proteins on electro-conductive polymer films , 1997 .

[25]  S. Omanovic,et al.  Interfacial Behavior of beta-Lactoglobulin at a Stainless Steel Surface: An Electrochemical Impedance Spectroscopy Study. , 2000, Journal of colloid and interface science.

[26]  Krister Holmberg,et al.  Influence of Surface Charge on Protein Adsorption at an Amphoteric Surface: Effects of Varying Acid to Base Ratio , 1996 .

[27]  P. Nellen,et al.  Output grating couplers on planar optical waveguides as direct immunosensors. , 1991, Biosensors & bioelectronics.

[28]  P. Fiévet,et al.  Influence of surface charge on adsorption of a hydrophobic peptide onto a carbon surface by capacitance measurements , 1998 .

[29]  S. G. Roscoe,et al.  Electrochemical Studies of the Adsorption Behavior of Bovine Serum Albumin on Stainless Steel , 1999 .

[30]  J. Andrade,et al.  Protein Adsorption on Low-Temperature Isotropic Carbon: II. Effects of Surface Charge of Solids , 1994 .

[31]  W. Lukosz,et al.  Sensitivity of grating couplers as integrated-optical chemical sensors , 1989 .