Pipeline burst detection and location using a continuous monitoring technique

Sudden pipe bursts occur in high-pressure water transmission pipelines and water distribution networks. The consequences of these bursts can be very expensive due to the outage time while the burst pipe is repaired, the cost of repair, and damage to surrounding property and infrastructure. As a result, it is advantageous to minimise the detection and location time after the burst occurs. This paper presents a continuous monitoring approach for the detection and location of pipeline bursts using pressure transients. Previous research has shown the potential of fluid transients for pipeline assessment. A sudden pipe burst creates a negative pressure wave that travels in both directions away from the burst point and is reflected at the pipe boundaries. Using pressure measured at one location, the timing of the initial and reflected burst-induced waves determines the location of the burst. The continuous monitoring technique uses the two-sided cumulative sum (CUSUM) algorithm to detect abrupt changes in the pressure data caused by the pipe break. The sensitivity of the algorithm is tuned such that the normal system/measurement noise does not initiate a false alarm. The continuous monitoring technique is verified using results from a laboratory pipeline. Different burst and measurement locations are tested. The results are promising for burst detection and location in real systems.

[1]  J. M. Rajtar,et al.  Pipeline leak detection system for oil and gas flowlines , 1997 .

[2]  Guangzhi Wang,et al.  Leak detection for transport pipelines based on autoregressive modeling , 1993 .

[3]  Shankar Narasimhan,et al.  Leak Detection in Networks of Pipelines by the Generalized Likelihood Ratio Method , 1996 .

[4]  Rolf Isermann,et al.  Process fault detection based on modeling and estimation methods - A survey , 1984, Autom..

[5]  Michèle Basseville,et al.  Detection of Abrupt Changes: Theory and Applications. , 1995 .

[6]  Sandra Lucia da Cruz,et al.  Pressure wave behaviour and leak detection in pipelines , 1996 .

[7]  Jean-Pierre Villeneuve,et al.  Modeling Water Pipe Breaks—Three Case Studies , 2003 .

[8]  D T Schlattman PRESSURE ANALYSIS IMPROVES LINES' LEAK-DETECTION CAPABILITIES , 1991 .

[9]  Yehia A. Khulief,et al.  A non-linear multiple-model state estimation scheme for pipeline leak detection and isolation , 2002 .

[10]  Ray S. Whaley,et al.  A Tutorial On Computer Based Leak Detection Methods , 1992 .

[11]  Angus R. Simpson,et al.  LEAK DETECTION IN PIPELINES USING THE DAMPING OF FLUID TRANSIENTS , 2002 .

[12]  J. C. P. Liou,et al.  Leak Detection—Transient Flow Simulation Approaches , 1995 .

[13]  E. S. Page CONTINUOUS INSPECTION SCHEMES , 1954 .

[14]  M. Larson,et al.  Leak Detection through Hydraulic Transient Analysis , 1992 .

[15]  Michèle Basseville,et al.  Detection of abrupt changes: theory and application , 1993 .

[16]  J. Liggett,et al.  Inverse Transient Analysis in Pipe Networks , 1994 .

[17]  Bruno Brunone,et al.  Transient Test-Based Technique for Leak Detection in Outfall Pipes , 1999 .