Application of Statistical Distribution Models to Predict Health Index for Condition-Based Management of Transformers

In this study, statistical distribution model (SDM) is used to predict the health index (HI) of transformers by utilizing the condition parameters data from dissolved gas analysis (DGA), oil quality analysis (OQA), and furanic compound analysis (FCA), respectively. First, the individual condition parameters data were categorized based on transformer age from year 1 to 15. Next, the individual condition parameters data for every age were fitted while using a probability plot to find the representative distribution models. The distribution parameters were calculated based on 95% confidence level and extrapolated from year 16 to 25 through representative fitting models. The individual condition parameters data within the period were later calculated based on the estimated distribution parameters through the inverse cumulative distribution function (ICDF) of the selected distribution models. The predicted HI was then determined based on the conventional scoring method. The Chi-square test for statistical hypothesis reveals that the predicted HI for the transformer data is quite close to the calculated HI. The average percentage of absolute error is 2.7%. The HI that is predicted based on SDM yields 97.83% accuracy for the transformer data.

[1]  Jau-Chuan Ke,et al.  Computation Approaches for Parameter Estimation of Weibull Distribution , 2012 .

[2]  Min Chen,et al.  Dynamic Fault Prediction of Power Transformers Based on Hidden Markov Model of Dissolved Gases Analysis , 2019, IEEE Transactions on Power Delivery.

[3]  Dan Zhou,et al.  TRANSFORMER LIFETIME MODELLING BASED ON CONDITION MONITORING DATA , 2013 .

[4]  Young Zaidey Yang Ghazali,et al.  Application of Markov Model to Estimate Individual Condition Parameters for Transformers , 2018 .

[5]  S. Ruhi,et al.  Mixture models for analyzing product reliability data: a case study , 2015, SpringerPlus.

[6]  Sandra Vītoliņa,et al.  Methods for Predicting Remaining Service Life of Power Transformers and Their Components , 2013 .

[7]  Rattanakorn Phadungthin,et al.  Condition assessment of the health index for power transformer , 2012, 2012 Power Engineering and Automation Conference.

[8]  Bo Qi,et al.  A Novel Deep Recurrent Belief Network Model for Trend Prediction of Transformer DGA Data , 2019, IEEE Access.

[9]  M. Abderrahmane,et al.  Two News Approximations to Standard Normal Distribution Function , 2016 .

[10]  Stefan Panic,et al.  Spare Parts Forecasting Based on Reliability , 2017 .

[11]  Dan Zhou Comparison of Two Popular Methods forTransformer Weibull Lifetime Modelling , 2013 .

[12]  I. Pobocikova,et al.  Comparison of four methods for estimating the Weibull distribution parameters , 2014 .

[13]  R. A. Abd El-Aal,et al.  Prediction of Transformers Conditions and Lifetime Using Furan Compounds Analysis , 2019, IEEE Access.

[15]  Ruchika Gupta,et al.  Failure rate prediction of equipment: can Weibull distribution be applied to automated hematology analyzers? , 2018, Clinical chemistry and laboratory medicine.

[16]  Khaled Bashir Shaban,et al.  Prediction of Transformer Furan Levels , 2016, IEEE Transactions on Power Delivery.

[17]  Jako Kilter,et al.  Health Index Prediction of Overhead Transmission Lines: A Machine Learning Approach , 2022, IEEE Transactions on Power Delivery.

[18]  Xuan Feng,et al.  Contact temperature prediction of high voltage switchgear based on multiple linear regression model , 2017, 2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC).

[19]  Raju Bala,et al.  Reliability analysis and failure rate evaluation of load haul dump machines using Weibull distribution analysis , 2018, Mathematical Modelling of Engineering Problems.

[20]  Siti Ahmad,et al.  Transformers Health Index Assessment Based on Neural-Fuzzy Network , 2018 .

[21]  Qiang Liu,et al.  Insulation Condition Ranking of Transformers through Principal Component Analysis and Analytic Hierarchy Process , 2017 .

[22]  N. Azis,et al.  Estimation of Transformers Health Index Based On Condition Parameter Factor and Hidden Markov Model , 2018, 2018 IEEE 7th International Conference on Power and Energy (PECon).

[23]  Wang Fan,et al.  An approach to power transformer asset management using health index , 2009, IEEE Electrical Insulation Magazine.

[24]  Aijun Yang,et al.  Failure Prognosis of High Voltage Circuit Breakers with Temporal Latent Dirichlet Allocation , 2017 .

[25]  Md Mominul Islam,et al.  Calculating a Health Index for Power Transformers Using a Subsystem-Based GRNN Approach , 2018, IEEE Transactions on Power Delivery.

[26]  Pei Yang,et al.  DGA and Weibull Distribution Model-based Transformer Fault Early Warning , 2019 .

[27]  Ashwani Kumar Chandel,et al.  Expert System for Health Index Assessment of Power Transformers , 2017 .

[28]  Hui Ma,et al.  Application of fuzzy support vector machine for determining the health index of the insulation system of in-service power transformers , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[29]  Mustafa Kaya,et al.  Comparison of Optimum Spline-Based Probability Density Functions to Parametric Distributions for the Wind Speed Data in Terms of Annual Energy Production , 2018, Energies.

[30]  Young Zaidey Yang Ghazali,et al.  A maintenance cost study of transformers based on Markov model utilizing frequency of transition approach , 2018 .

[31]  A. G. Thosar,et al.  Prognostication Of Health Index For Oil-Immersed Transformers Using Random Forest , 2019 .

[32]  Y. Xiaowei,et al.  Estimation on Reliability Models of Bearing Failure Data , 2018 .

[33]  A. Barabadi,et al.  Reliability and spare parts estimation taking into consideration the operational environment — A case study , 2012, 2012 IEEE International Conference on Industrial Engineering and Engineering Management.

[34]  Massimo Pompili,et al.  Transformers Fleet Management Through the use of an Advanced Health Index , 2018, 2018 IEEE Electrical Insulation Conference (EIC).

[35]  Paritosh Bhattacharya,et al.  A Study on Weibull Distribution for Estimating the Parameters , 2009 .

[36]  Mohd Zainal Abidin Ab Kadir,et al.  Estimation of Transformers Health Index Based on the Markov Chain , 2017 .

[37]  Filip Zec,et al.  Prediction of high-voltage asynchronous machines stators insulation status applying law on increasing probability , 2020 .