Half-power test of a CW proton injector with a 1.25-MeV RFQ

A 75-keV, 110-mA CW proton injector capable of pulsed operation has been developed for testing the LEDA 6.7-MeV CW radio frequency quadrupole (RFQ). Part of the preliminary development of this injector included operation of a 1.25-MeV CW RFQ at beam currents up to 100 mA. The 75-keV LEDA injector was modified to operate at 50 keV for these tests. We report here on the operational experience of the 1.25-MeV RFQ where 50-mA beam current was accelerated through the RFQ with 90% transmission. This half-power operation is of interest because (1) the injector beam current monitoring was more reliable, and (2) sufficient RF power was available to ensure the design cavity fields. These two features simplify the comparison of injector-RFQ performance with design codes. The information obtained from these studies will be applied to the 75-keV injector during the LEDA 6.7-MeV RFQ commissioning.

[1]  P. McGehee,et al.  Commissioning of the Low Energy Demonstration Accelerator (LEDA) radiofrequency quadrupole (RFQ) , 1999, Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366).

[2]  J. D. Schneider,et al.  Operation of the Low-Energy Demonstration Accelerator: the proton injector for APT , 1999, Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366).

[3]  L. Young,et al.  Comparison of beam simulations with measurements for a 1.25-MeV, CW RFQ , 1998 .

[4]  T. Hardek,et al.  A dc proton injector for use in high-current cw linacs , 1998 .

[5]  E. A. Meyer,et al.  Status report on a dc 130 mA, 75 keV proton injector (invited) , 1997 .

[6]  A. Pochelon Electron Cyclotron Resonance Ion Sources and ECR Plasmas , 1997 .

[7]  J. E. Boers,et al.  An interactive version of the PBGUNS program for the simulation of axisymmetric and 2-D, electron and ion beams and guns , 1995, Proceedings Particle Accelerator Conference.

[8]  J. D. Schneider,et al.  Installation of a CW Radiofrequency Quadrupole Accelerator at Los Alamos National Laboratory , 1994 .

[9]  J. F. Mouris,et al.  An advanced high-current low-emittance dc microwave proton source , 1993 .

[10]  M. Olivo,et al.  The PSI 870 keV high intensity Cockcroft–Walton preinjector , 1992 .

[11]  G. Mcmichael,et al.  New vanes for RFQ1: fabrication, installation, and tuning , 1991, Conference Record of the 1991 IEEE Particle Accelerator Conference.

[12]  G. Allan Application of a scanning proton microprobe as a diagnostic tool and the development of a high brightness ion source , 1989 .