Passive 350 GHz Video Imaging Systems for Security Applications

Passive submillimeter-wave imaging is a concept that has been in the focus of interest as a promising technology for personal security screening for a number of years. In contradiction to established portal-based millimeter-wave scanning techniques, it allows for scanning people from a distance in real time with high throughput and without a distinct inspection procedure. This opens up new possibilities for scanning, which directly address an urgent security need of modern societies: protecting crowds and critical infrastructure from the growing threat of individual terror attacks. Considering the low radiometric contrast of indoor scenes in the submillimeter range, this objective calls for an extremely high detector sensitivity that can only be achieved using cooled detectors. Our approach to this task is a series of passive standoff video cameras for the 350 GHz band that represent an evolving concept and a continuous development since 2007. Arrays of superconducting transition-edge sensors (TES), operated at temperatures below 1 K, are used as radiation detectors. By this means, background limited performance (BLIP) mode is achieved, providing the maximum possible signal to noise ratio. At video rates, this leads to a temperature resolution well below 1 K. The imaging system is completed by reflector optics based on free-form mirrors. For object distances of 5–25 m, a field of view up to 2 m height and a diffraction-limited spatial resolution in the order of 1–2 cm is provided. Opto-mechanical scanning systems are part of the optical setup and capable of frame rates of up to 25 frames per second.

[1]  Erik Heinz,et al.  Passive Submillimeter-wave Stand-off Video Camera for Security Applications , 2010 .

[2]  Erik Heinz,et al.  Next generation of a sub-millimetre wave security camera utilising superconducting detectors , 2013 .

[3]  J. Bock,et al.  Relative performance of filled and feedhorn-coupled focal-plane architectures. , 2002, Applied optics.

[4]  Hans-Georg Meyer,et al.  Structured SiN membranes as platform for cryogenic bolometers , 2009 .

[5]  G. Rieke Books-Received - Detection of Light - from the Ultraviolet to the Submillimeter , 1995 .

[6]  Joseph A. Shaw,et al.  Radiometry and the Friis transmission equation , 2013 .

[7]  Peter A. R. Ade,et al.  A 350-GHz high-resolution high-sensitivity passive video imaging system , 2010, Defense + Commercial Sensing.

[8]  Solveig Anders,et al.  Structural and electrical properties of AuPd/Mo bi-layer films for transition edge sensors , 2006 .

[9]  Duncan A. Robertson,et al.  Concealed threat detection with the IRAD sub-millimeter wave 3D imaging radar , 2014, Defense + Security Symposium.

[10]  Duncan A. Robertson,et al.  Passive and active imaging at 94 GHz for environmental remote sensing , 2013, Defense, Security, and Sensing.

[11]  J. Zmuidzinas Thermal noise and correlations in photon detection. , 2003, Applied optics.

[12]  Erich N. Grossman,et al.  Passive hyperspectral terahertz imagery for security screening using a cryogenic microbolometer , 2005, SPIE Defense + Commercial Sensing.

[13]  George Rieke,et al.  Detection of Light: Index , 2002 .

[14]  Christopher J. Mann First demonstration of a vehicle mounted 250GHz real time passive imager , 2009, Defense + Commercial Sensing.

[15]  Patrick Lj Valdez,et al.  Standoff concealed weapon detection using a 350-GHz radar imaging system , 2010, Defense + Commercial Sensing.

[16]  Jörn Beyer,et al.  Code-division multiplexing of superconducting transition-edge sensor arrays , 2010 .

[17]  Erik Heinz,et al.  Time-domain multiplexed SQUID readout of a bolometer camera for APEX , 2011 .

[18]  Peter H. Siegel,et al.  Fast high-resolution terahertz radar imaging at 25 meters , 2010, Defense + Commercial Sensing.

[19]  Fiona A. Harrison,et al.  Position sensitive x-ray spectrophotometer using microwave kinetic inductance detectors , 2006 .

[20]  Erik Heinz,et al.  Toward high-sensitivity and high-resolution submillimeter-wave video imaging , 2011 .

[21]  Mikko Leivo,et al.  Measured performance of a high-resolution passive video-rate submillimeter-wave imaging system demonstrator for stand-off imaging , 2012, Defense + Commercial Sensing.

[22]  E. Pascale,et al.  The “KIDcam” passive THz imager; Recent developments , 2014, 2014 39th International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz).

[23]  Erik Heinz,et al.  Dynamic behavior of dc SQUIDs in time-division multiplexing readout schemes , 2013 .

[24]  B. Bumble,et al.  ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging Spectrophotometer , 2013, 1306.4674.

[25]  Torsten May,et al.  A superconducting terahertz imager , 2007, SPIE Defense + Commercial Sensing.

[26]  P. Richards Bolometers for infrared and millimeter waves , 1994 .

[27]  Peter Ade,et al.  Standoff passive video imaging at 350 GHz with 251 superconducting detectors , 2014, Defense + Security Symposium.

[28]  Torsten May,et al.  Passive stand-off terahertz imaging with 1 hertz frame rate , 2008, SPIE Defense + Commercial Sensing.

[29]  Erik Heinz,et al.  Development of passive submillimeter-wave video imaging systems for security applications , 2012, Optics/Photonics in Security and Defence.

[30]  S. Alekseev,et al.  Human skin permittivity determined by millimeter wave reflection measurements , 2007, Bioelectromagnetics.

[31]  Erik Heinz,et al.  Progress in passive submillimeter-wave video imaging , 2014, Defense + Security Symposium.

[32]  K. Irwin,et al.  Superconducting multiplexer for arrays of transition edge sensors , 1999 .

[33]  H.B. Wallace,et al.  Standoff Detection of Weapons and Contraband in the 100 GHz to 1 THz Region , 2007, IEEE Transactions on Antennas and Propagation.

[34]  Michael S. Shur,et al.  Terahertz Physics, Devices, and Systems II , 2006 .