Automation in biobanking from a laboratory medicine perspective

Abstract Biobanks are important infrastructures to support clinical research and developments in personalized medicine. Although biobanking is not a new invention it has gained importance in the last few years due to increased quality requirements for biological samples in biomedical research and new high resolution Omics-technologies. Moreover, quality-assured collection, processing and storage of biological samples with defined pre-analytical history plays a key role for reproducibility in scientific research and paves the path towards precision medicine. Due to the increasing need for large numbers of samples, both in basic as well as in translational research, particular attention must be paid to sample acquisition and preparation in order to guarantee the highest possible sample quality. This can be achieved by following best practices or implementation and operation of specific biobank quality management systems that are compliant with the new DIN EN ISO 20387. Moreover, automation of critical process steps in biobanking can help to reach the highest quality standard and consistent sample quality. The following article will present and discuss currently available solutions for process automation in biobanking.

[1]  J. Malm,et al.  Semi-automated biobank sample processing with a 384 high density sample tube robot used in cancer and cardiovascular studies , 2015, Clinical and Translational Medicine.

[2]  C. Compton,et al.  Assessing the need for a standardized cancer HUman Biobank (caHUB): findings from a national survey with cancer researchers. , 2011, Journal of the National Cancer Institute. Monographs.

[3]  S. Schmitt,et al.  Qualität von Biomaterialien im Biobanking von Flüssig- und Gewebeproben , 2016, Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz.

[4]  Joachim Thiery,et al.  Comparison of Whole Blood RNA Preservation Tubes and Novel Generation RNA Extraction Kits for Analysis of mRNA and MiRNA Profiles , 2014, PloS one.

[5]  HubelAllison,et al.  Storage of Human Biospecimens: Selection of the Optimal Storage Temperature , 2014 .

[6]  Kaveh G Shojania,et al.  Classifying laboratory incident reports to identify problems that jeopardize patient safety. , 2003, American journal of clinical pathology.

[7]  E. Drucker,et al.  Pitfalls and limitations in translation from biomarker discovery to clinical utility in predictive and personalised medicine , 2013, EPMA Journal.

[8]  G. Fiedler,et al.  Der „fehlerhafte“ Laborbefund , 2004, Der Internist.

[9]  Jim Vaught,et al.  Preanalytical variables affecting the integrity of human biospecimens in biobanking. , 2015, Clinical chemistry.

[10]  Die Biobank der Nationalen Kohorte als Ressource der epidemiologischen Forschung , 2016, Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz.

[11]  A. Petersmann,et al.  Determination of hemolysis thresholds by the use of data loggers in pneumatic tube systems. , 2011, Clinical chemistry.

[12]  Brent Schacter,et al.  Standardization and Innovation in Paving a Path to a Better Future: An Update of Activities in ISO/TC276/WG2 Biobanks and Bioresources. , 2018, Biopreservation and biobanking.

[13]  L. Lind,et al.  Effects of Long-Term Storage at −80 °C on the Human Plasma Metabolome , 2019, Metabolites.

[14]  Sharmeela Kaushal,et al.  Real-Time Temperature Mapping in Ultra-Low Freezers as a Standard Quality Assessment. , 2019, Biopreservation and biobanking.

[15]  Erik Peter,et al.  Quality markers addressing preanalytical variations of blood and plasma processing identified by broad and targeted metabolite profiling. , 2014, Clinical chemistry.

[16]  M Plebani,et al.  Mistakes in a stat laboratory: types and frequency. , 1997, Clinical chemistry.

[17]  Hüseyin Erdal,et al.  The Effect of Pneumatic Tube Systems on the Hemolysis of Biochemistry Blood Samples , 2017, Journal of emergency nursing: JEN : official publication of the Emergency Department Nurses Association.

[18]  U. Ceglarek,et al.  Preanalytical Investigation of Polyunsaturated Fatty Acids and Eicosanoids in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry. , 2016, Biopreservation and biobanking.

[19]  N. Klopp,et al.  Quality Assessment of the Preanalytical Workflow in Liquid Biobanking: Taurine as a Serum-Specific Quality Indicator for Preanalytical Process Variations. , 2019, Biopreservation and biobanking.

[20]  Mario Plebani,et al.  Errors in a stat laboratory: types and frequencies 10 years later. , 2007, Clinical chemistry.

[21]  Joachim Thiery,et al.  Effect of biobanking conditions on short-term stability of biomarkers in human serum and plasma , 2014, Clinical chemistry and laboratory medicine.

[22]  T. Szekeres,et al.  The effect of storage temperature fluctuations on the stability of biochemical analytes in blood serum , 2017, Clinical chemistry and laboratory medicine.

[23]  I. Cockburn,et al.  The Economics of Reproducibility in Preclinical Research , 2015, PLoS biology.

[24]  H. Haenssle,et al.  Controlled-rate freezer cryopreservation of highly concentrated peripheral blood mononuclear cells results in higher cell yields and superior autologous T-cell stimulation for dendritic cell-based immunotherapy , 2012, Cancer Immunology, Immunotherapy.

[25]  P. Toniolo,et al.  Temperature variations in upright mechanical freezers. , 1996, Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology.

[26]  Paul Elliott,et al.  The UK Biobank sample handling and storage validation studies. , 2008, International journal of epidemiology.