A comparison of four algorithms for metal artifact reduction in CT imaging

Streak artifacts caused by the presence of metal have been a significant problem in CT imaging since its inception in 1972. With the fast evolving medical device industry, the number of metal objects implanted in patients is increasing annually. This correlates directly with an increased likelihood of encountering metal in a patient CT scan, thus necessitating the need for an effective and reproducible metal artifact reduction (MAR) algorithm. Previous comparisons between MAR algorithms have typically only evaluated a small number of patients and a limited range of metal implants. Although the results of many methods are promising, the reproducibility of these results is key to providing more tangible evidence of their effectiveness. This study presents a direct comparison between the performances, assessed by board certified radiologists, of four MAR algorithms: 3 non-iterative and one iterative method, all applied and compared to the original clinical images. The results of the evaluation indicated a negative mean score in almost all uses for two of the non-iterative methods, signifying an overall decrease in the diagnostic quality of the images, generally due to perceived loss of detail. One non-iterative algorithm showed a slight improvement. The iterative algorithm was superior in all studies by producing a considerable improvement in all uses.

[1]  G. Glover,et al.  An algorithm for the reduction of metal clip artifacts in CT reconstructions. , 1981, Medical physics.

[2]  Lothar Spies,et al.  Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. , 2006, Medical physics.

[3]  M W Vannier,et al.  Fast iterative algorithm for metal artifact reduction in X-ray CT. , 2000, Academic radiology.

[4]  Joseph A. O'Sullivan,et al.  Iterative deblurring for CT metal artifact reduction , 1996, IEEE Trans. Medical Imaging.

[5]  Jiang Hsieh,et al.  Computed Tomography: Principles, Design, Artifacts, and Recent Advances, Fourth Edition , 2022 .

[6]  Jikun Wei,et al.  X-ray CT high-density artefact suppression in the presence of bones , 2004, Physics in medicine and biology.

[7]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[8]  W. Kalender,et al.  A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images , 2004, European Radiology.

[9]  Norbert J. Pelc,et al.  SU‐EE‐A4‐03: Metal Artifact Reduction Algorithm for X‐Ray CT Using a Three‐Pass Approach , 2009 .

[10]  Tobias Funk,et al.  Computed Tomographic Metal Artifact Reduction for the Detection and Quantitation of Small Features Near Large Metallic Implants: A Comparison of Published Methods , 2008, Journal of computer assisted tomography.

[11]  Gary H. Glover,et al.  An algorithm for the reduction of metal clip artifacts in CT reconstructions. , 1981 .

[12]  Julia F. Barrett,et al.  Artifacts in CT: recognition and avoidance. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.