Design, Development and Testing of a Low-Cost sEMG System and Its Use in Recording Muscle Activity in Human Gait

Surface electromyography (sEMG) is an important measurement technique used in biomechanical, rehabilitation and sport environments. In this article the design, development and testing of a low-cost wearable sEMG system are described. The hardware architecture consists of a two-cascade small-sized bioamplifier with a total gain of 2,000 and band-pass of 3 to 500 Hz. The sampling frequency of the system is 1,000 Hz. Since real measured EMG signals are usually corrupted by various types of noises (motion artifacts, white noise and electromagnetic noise present at 50 Hz and higher harmonics), we have tested several denoising techniques, both on artificial and measured EMG signals. Results showed that a wavelet—based technique implementing Daubechies5 wavelet and soft sqtwolog thresholding is the most appropriate for EMG signals denoising. To test the system performance, EMG activities of six dominant muscles of ten healthy subjects during gait were measured (gluteus maximus, biceps femoris, sartorius, rectus femoris, tibialis anterior and medial gastrocnemius). The obtained EMG envelopes presented against the duration of gait cycle were compared favourably with the EMG data available in the literature, suggesting that the proposed system is suitable for a wide range of applications in biomechanics.

[1]  Ante Panjkota,et al.  Design, development and evaluation of optical motion-tracking system based on active white light markers , 2013 .

[2]  Patricia Fernández,et al.  Man-Machine Interface System for Neuromuscular Training and Evaluation Based on EMG and MMG Signals , 2010, Sensors.

[3]  André Fabio Kohn,et al.  A method to estimate EMG crosstalk between two muscles based on the silent period following an H-reflex. , 2009, Medical engineering & physics.

[4]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[5]  E L Morin,et al.  Sampling, noise-reduction and amplitude estimation issues in surface electromyography. , 2002, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[6]  L. Maletsky,et al.  Accuracy of an optical active-marker system to track the relative motion of rigid bodies. , 2007, Journal of biomechanics.

[7]  J. Fang,et al.  Decomposition of multiunit electromyographic signals , 1999, IEEE Transactions on Biomedical Engineering.

[8]  Truong Q. Nguyen,et al.  Wavelets and filter banks , 1996 .

[9]  R. Brand,et al.  The biomechanics and motor control of human gait: Normal, elderly, and pathological , 1992 .

[10]  Alonso Alonso,et al.  Programmable Gain Amplifiers with DC Suppression and Low Output Offset for Bioelectric Sensors , 2013, Sensors.

[11]  Thomas B. Moeslund,et al.  A Survey of Computer Vision-Based Human Motion Capture , 2001, Comput. Vis. Image Underst..

[12]  Slawomir J. Nasuto,et al.  EMG Decomposition and Artefact Removal , 2012 .

[13]  J L Garrido Castro,et al.  Design and evaluation of a new three-dimensional motion capture system based on video. , 2006, Gait & posture.

[14]  David L. Donoho,et al.  De-noising by soft-thresholding , 1995, IEEE Trans. Inf. Theory.

[15]  M. Perc The dynamics of human gait , 2005 .

[16]  Mamun Bin Ibne Reaz,et al.  Surface Electromyography Signal Processing and Classification Techniques , 2013, Sensors.

[17]  D Farina,et al.  Surface EMG Crosstalk Evaluated from Experimental Recordings and Simulated Signals , 2004, Methods of Information in Medicine.

[18]  Peter J. Kyberd,et al.  EMG signal filtering based on Empirical Mode Decomposition , 2006, Biomed. Signal Process. Control..

[19]  S Conforto,et al.  Optimal rejection of movement artefacts from myoelectric signals by means of a wavelet filtering procedure. , 1999, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[20]  M. Alizadeh,et al.  Design of a marker-based human motion tracking system , 2007, Biomed. Signal Process. Control..

[21]  Jean-Michel Poggi,et al.  Wavelet Toolbox User s Guide , 1996 .

[22]  Kang-Ming Chang,et al.  A Wireless sEMG Recording System and Its Application to Muscle Fatigue Detection , 2012, Sensors.

[23]  Markus Windolf,et al.  Systematic accuracy and precision analysis of video motion capturing systems--exemplified on the Vicon-460 system. , 2008, Journal of biomechanics.

[24]  C. J. Luca,et al.  SURFACE ELECTROMYOGRAPHY : DETECTION AND RECORDING , 2022 .

[25]  C. A. Grimbergen,et al.  Amplifiers for bioelectric events: A design with a minimal number of parts , 1994, Medical and Biological Engineering and Computing.

[26]  Vlasta Zanchi,et al.  Improved structured light 3D scanner with application to anthropometric parameter estimation , 2013 .

[27]  Farbod Razzazi,et al.  Elimination of power line noise from EMG signals using an efficient adaptive Laguerre filter , 2010, ICSES 2010 International Conference on Signals and Electronic Circuits.

[28]  I. Johnstone,et al.  Ideal denoising in an orthonormal basis chosen from a library of bases , 1994 .

[29]  Slawomir J. Nasuto,et al.  The application of the Hilbert spectrum to the analysis of electromyographic signals , 2008, Inf. Sci..

[30]  Richard A. Brand,et al.  The biomechanics and motor control of human gait: Normal, elderly, and pathological , 1992 .

[31]  Andreas Daffertshofer,et al.  Removing ECG contamination from EMG recordings: a comparison of ICA-based and other filtering procedures. , 2012, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[32]  D. Farina,et al.  Accessing the Neural Drive to Muscle and Translation to Neurorehabilitation Technologies , 2012, IEEE Reviews in Biomedical Engineering.