Single-pixel imaging by Hadamard transform and its application for hyperspectral imaging

In this paper, we report on comparisons of single-pixel imagings using Hadamard Transform (HT) and the ghost imaging (GI) in the view point of the visibility under weak light conditions. For comparing the two methods, we have discussed about qualities of images based on experimental results and numerical analysis. To detect images by the TH method, we have illuminated the Hadamard-pattern mask and calculated by orthogonal transform. On the other hand, the GH method can detect images by illuminating random patterns and a correlation measurement. For comparing two methods under weak light intensity, we have controlled illuminated intensities of a DMD projector about 0.1 in signal-to-noise ratio. Though a process speed of the HT image was faster then an image via the GI, the GI method has an advantage of detection under weak light condition. An essential difference between the HT and the GI method is discussed about reconstruction process. Finally, we also show a typical application of the single-pixel imaging such as hyperspectral images by using dual-optical frequency combs. An optical setup consists of two fiber lasers, spatial light modulated for generating patten illumination, and a single pixel detector. We are successful to detect hyperspectrul images in a range from 1545 to 1555 nm at 0.01nm resolution.

[1]  Guolan Lu,et al.  Medical hyperspectral imaging: a review , 2014, Journal of biomedical optics.

[2]  J. Qin,et al.  Detection of citrus canker using hyperspectral reflectance imaging with spectral information divergence , 2009 .

[3]  A. Gatti,et al.  Ghost imaging with thermal light: comparing entanglement and classical correlation. , 2004, Physical review letters.

[4]  M. Padgett,et al.  3D Computational Imaging with Single-Pixel Detectors , 2013, Science.

[5]  Yud-Ren Chen,et al.  Hyperspectral imaging for safety inspection of food and agricultural products , 1999, Other Conferences.

[6]  J.L. Hall,et al.  Optical frequency measurement: 40 years of technology revolutions , 2000, IEEE Journal of Selected Topics in Quantum Electronics.

[7]  Daniel W. Wilson,et al.  Snapshot hyperspectral imaging in ophthalmology. , 2007, Journal of biomedical optics.

[8]  Jun Ye,et al.  Delivery of high-stability optical and microwave frequency standards over an optical fiber network , 2003 .

[9]  J. A. Decker,et al.  Hadamard transform imager and imaging spectrometer. , 1976, Applied optics.

[10]  Shih,et al.  Optical imaging by means of two-photon quantum entanglement. , 1995, Physical review. A, Atomic, molecular, and optical physics.

[11]  Kyuki Shibuya,et al.  Comparison of reconstructed images between ghost imaging and Hadamard transform imaging , 2015 .

[12]  Robert W Boyd,et al.  Optimization of thermal ghost imaging: high-order correlations vs. background subtraction. , 2010, Optics express.

[13]  Rainer Riesenberg,et al.  HADAMARD imaging spectrometer with microslit matrix , 1999, Optics & Photonics.

[14]  Tien-Hsin Chao,et al.  Hyperspectral imaging using electro-optic Fourier transform spectrometer , 2004, SPIE Defense + Commercial Sensing.

[15]  L. Christophorou Science , 2018, Emerging Dynamics: Science, Energy, Society and Values.

[16]  Jeffrey H. Shapiro,et al.  Computational ghost imaging , 2008, 2009 Conference on Lasers and Electro-Optics and 2009 Conference on Quantum electronics and Laser Science Conference.