Insertion torque is not a good predictor of pedicle screw loosening after spinal instrumentation: a prospective study in 8 patients

BackgroundPedicle screw loosening is a major safety concern in instrumented spinal surgery due to loosening with potential pseudarthrosis and possible loss of correction requiring revision surgery. Several cadaver studies have compared insertion torque of pedicle screws with resistance to pullout or cyclic loading. In most of these studies, a correlation has been found between these variables. Clinical studies have been made, comparing insertion torque to bone mineral density or radiological signs of screw loosening. There are no clinical studies comparing insertion torque to extraction torque or other biomechanical parameters in vivo. This study was designed to investigate whether the insertion torque of pedicle screws can be used to predict the purchase of the screws.MethodsThe insertion torque of stainless steel pedicle screws was recorded in eight patients undergoing lumbar fusion surgery with four-screw constructs. Torque gauge manometers were used for the recordings. The implants were removed after one year, and the extraction torque of the screws was recorded.ResultsThe mean insertion torque was 76 ± 41 Ncm and the mean extraction torque 29 ± 36 Ncm. The r value was 0.591, suggesting that there was a correlation between the insertion and extraction torque. However, the scattergram revealed that the screws could be divided into two groups, six screws with a high correlation between insertion and extraction torque, and 26 screws where no correlation could be demonstrated.ConclusionsIn this unique human in-vivo study, the insertion torque could not be used to predict the purchase of lumbar pedicle screws one year after implantation. It could be demonstrated that in vivo insertion torque alone is of minor value to estimate pullout strength, and should be combined with or replaced by more accurate measures.

[1]  K. Luk,et al.  Loosening of sacral screw fixation under in vitro fatigue loading , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[2]  K. Okuyama,et al.  Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion. , 2000, Spine.

[3]  I. Redlund‐Johnell,et al.  Complications After Transpedicular Stabilization of the Spine: A Survivorship Analysis of 163 Cases , 1994, Spine.

[4]  B. Myers,et al.  The Role of Imaging and In Situ Biomechanical Testing in Assessing Pedicle Screw Pull‐Out Strength , 1996, Spine.

[5]  S. Esses,et al.  Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. , 1993, Spine.

[6]  K Okuyama,et al.  Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability. , 1993, Spine.

[7]  X. Weng,et al.  [Complications associated with the technique of pedicle screw fixation]. , 2002, Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae.

[8]  B. Sandén,et al.  Improved extraction torque of hydroxyapatite-coated pedicle screws , 2000, European Spine Journal.

[9]  R. McLain,et al.  Pedicle screw fixation strength: pullout versus insertional torque. , 2004, The spine journal : official journal of the North American Spine Society.

[10]  W C Hutton,et al.  Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws. , 1994, Journal of spinal disorders.

[11]  J W Frymoyer,et al.  An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine. Design and testing. , 1986, Clinical orthopaedics and related research.

[12]  T C Hearn,et al.  Insertional Torque and Pull‐out Strengths of Conical and Cylindrical Pedicle Screws in Cadaveric Bone , 1996, Spine.

[13]  S. Ohtori,et al.  Insertional torque of the lumbar pedicle screw during surgery , 2005, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[14]  D. W. Bühler,et al.  Moments and Forces During Pedicle Screw Insertion: In Vitro and In Vivo Measurements , 1998, Spine.

[15]  O. Böstman,et al.  Complications of transpedicular lumbosacral fixation for non-traumatic disorders. , 1997, The Journal of bone and joint surgery. British volume.

[16]  B. Sandén,et al.  The significance of radiolucent zones surrounding pedicle screws. Definition of screw loosening in spinal instrumentation. , 2004, The Journal of bone and joint surgery. British volume.

[17]  B. Sandén,et al.  Hydroxyapatite coating improves fixation of pedicle screws. A clinical study. , 2002, The Journal of bone and joint surgery. British volume.

[18]  J. Dove,et al.  Pedicle screws: axial pull-out strength in the lumbar spine. , 1988, Spine.

[19]  K. Shinomiya,et al.  Intraoperative insertion torque of lumbar pedicle screw and postoperative radiographic evaluation: short-term observation , 2005, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[20]  D N Kunz,et al.  Pedicle Screw Pullout Strength: Correlation with Insertional Torque , 1993, Spine.

[21]  Vivek Trikha,et al.  Clinical Study , 1961, Acta neurologica Scandinavica.

[22]  D J Downey,et al.  Optimizing Bone Screw Pullout Force , 1990, Journal of orthopaedic trauma.

[23]  K. Murota,et al.  An Experimental Study on Transpedicular Screw Fixation in Relation to Osteoporosis of the Lumbar Spine , 1991, Spine.

[24]  H. Alaranta,et al.  Spondylodesis augmented by transpedicular fixation in the treatment of olisthetic and degenerative conditions of the lumbar spine. , 1993, Clinical orthopaedics and related research.

[25]  Mauz Jj,et al.  The effect of lumbar belts on isolated lumbar muscle. , 1995 .

[26]  B. Sandén,et al.  Hydroxyapatite coating improves fixation of pedicle screws , 2002 .

[27]  奥山 幸一郎,et al.  Stability of transpedicle screwing for the osteoporotic spine , 1994 .