Tomographic mapping of the hard palate and overlying mucosa.

The aim of this study was to measure the thickness of the hard palate and its overlying mucosa using cone-beam computed tomography (CBCT), for purposes of miniscrew placement. The sample comprised 36 CBCT scans of patients aged 12 to 52 years from a database of the Orthodontics Department of the Federal University of Rio de Janeiro. Paracoronal views of the palatal region were reconstructed at 4, 8, 16 and 24 mm posterior to the incisive foramen. In each reconstruction measurements were taken at the suture, 3 mm and 6 mm bilaterally to it. Wilcoxon's test verified the differences between the selected regions. Total bone height decreased from the anterior to the posterior region. In cross sections 4, 16 and 24, bone height decreased from the suture laterally to the 3 mm region and then increased in the 6 mm region. The cortical thickness does not seem to be a concern because it presented a mean thickness of at least 1 mm at all sites evaluated. The measurements of the mucosa thickness decreased from lateral to median and from anterior to posterior regions. The most suitable areas for miniscrew placement in the palate are located 4 mm posterior to the incisive foramen, in the median or paramedian regions 3 mm adjacent to the suture.

[1]  L. I. Nojima,et al.  Assessment of mini-implant displacement using cone beam computed tomography. , 2011, Clinical oral implants research.

[2]  Min-Suk Heo,et al.  Bone thickness of the palate for orthodontic mini-implant anchorage in adults. , 2007, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[3]  Young-chel Park,et al.  The efficient use of midpalatal miniscrew implants. , 2009, The Angle orthodontist.

[4]  Paul W Major,et al.  Vertical bone volume in the paramedian palate of adolescents: a computed tomography study. , 2007, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[5]  Sang-Heng Kok,et al.  A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. , 2004, The International journal of oral & maxillofacial implants.

[6]  L. I. Nojima,et al.  Transverse effects of rapid maxillary expansion in Class II malocclusion patients : A Cone-Beam Computed Tomography study , 2010 .

[7]  R Kanomi,et al.  Mini-implant for orthodontic anchorage. , 1997, Journal of clinical orthodontics : JCO.

[8]  L. Lombardo,et al.  Quantitative cone-beam computed tomography evaluation of palatal bone thickness for orthodontic miniscrew placement. , 2008, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[9]  S. Baek,et al.  Soft tissue thickness for placement of an orthodontic miniscrew using an ultrasonic device. , 2008, The Angle orthodontist.

[10]  Sung Hee Moon,et al.  Palatal bone density in adult subjects: implications for mini-implant placement. , 2010, The Angle orthodontist.

[11]  Seong-Ho Choi,et al.  Thickness of Posterior Palatal Masticatory Mucosa: The Use of Computerized Tomography , 2008 .

[12]  M. Marquezan,et al.  Is miniscrew primary stability influenced by bone density? , 2011, Brazilian oral research.

[13]  H. Wehrbein,et al.  Palatal bone support for orthodontic implant anchorage--a clinical and radiological study. , 1999, European journal of orthodontics.

[14]  Doo-Hyung Kim,et al.  Soft-tissue and cortical-bone thickness at orthodontic implant sites. , 2006, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[15]  H. Imhof,et al.  Dental CT and orthodontic implants: imaging technique and assessment of available bone volume in the hard palate. , 2004, European journal of radiology.

[16]  Jang-Jaer Lee,et al.  Maxillary molar intrusion with fixed appliances and mini-implant anchorage studied in three dimensions. , 2009, The Angle orthodontist.

[17]  Aldo Carano,et al.  Clinical applications of the Miniscrew Anchorage System. , 2005, Journal of clinical orthodontics : JCO.

[18]  Sebastian Baumgaertel,et al.  Quantitative investigation of palatal bone depth and cortical bone thickness for mini-implant placement in adults. , 2009, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[19]  Carolina Baratieri,et al.  Efeitos transversais da expansão rápida da maxila em pacientes com má oclusão de Classe II: avaliação por Tomografia Computadorizada Cone-Beam , 2010 .

[20]  B. Melsen Mini-implants: Where are we? , 2005, Journal of clinical orthodontics : JCO.

[21]  Antonio Gracco,et al.  Optimal palatal configuration for miniscrew applications. , 2010, The Angle orthodontist.

[22]  T. Takano-Yamamoto,et al.  Titanium screw anchorage for traction of many impacted teeth in a patient with cleidocranial dysplasia. , 2007, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[23]  S. Kyung,et al.  Distalization of maxillary molars with a midpalatal miniscrew. , 2003, Journal of clinical orthodontics : JCO.

[24]  Maurício Barriviera,et al.  Soft tissue cone-beam computed tomography: a novel method for the measurement of gingival tissue and the dimensions of the dentogingival unit. , 2008, Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.].

[25]  C. Arcuri,et al.  Five years of experience using palatal mini-implants for orthodontic anchorage. , 2007, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[26]  J. Faber,et al.  A new method to assess and measure palatal masticatory mucosa by cone-beam computerized tomography. , 2009, Journal of clinical periodontology.

[27]  R. Haas,et al.  Alternative to the median region of the palate for placement of an orthodontic implant. , 2000, Clinical oral implants research.

[28]  Tohru Yoshida,et al.  Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. , 2007, The International journal of oral & maxillofacial implants.