Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro

MethodsIn this study we determined, for the first time, the ability of microorganisms to traverse microneedle-induced holes using two different in vitro models.ResultsWhen employing Silescol® membranes, the numbers of Candida albicans, Pseudomonas aeruginosa and Staphylococcus epidermidis crossing the membranes were an order of magnitude lower when the membranes were punctured by microneedles rather than a 21G hypodermic needle. Apart from the movement of C. albicans across hypodermic needle-punctured membranes, where 40.2% of the microbial load on control membranes permeated the barrier over 24 h, the numbers of permeating microorganisms was less than 5% of the original microbial load on control membranes. Experiments employing excised porcine skin and radiolabelled microorganisms showed that the numbers of microorganisms penetrating skin beyond the stratum corneum were approximately an order of magnitude greater than the numbers crossing Silescol® membranes in the corresponding experiments. Approximately 103 cfu of each microorganism adhered to hypodermic needles during insertion. The numbers of microorganisms adhering to MN arrays were an order of magnitude higher in each case.ConclusionWe have shown here that microneedle puncture resulted in significantly less microbial penetration than did hypodermic needle puncture and that no microorganisms crossed the viable epidermis in microneedle—punctured skin, in contrast to needle-punctured skin. Given the antimicrobial properties of skin, it is, therefore, likely that application of microneedle arrays to skin in an appropriate manner would not cause either local or systemic infection in normal circumstances in immune-competent patients. In supporting widespread clinical use of microneedle-based delivery systems, appropriate animal studies are now needed to conclusively demonstrate this in vivo. Safety in patients will be enhanced by aseptic or sterile manufacture and by fabricating microneedles from self-disabling materials (e.g. dissolving or biodegradable polymers) to prevent inappropriate or accidental reuse.

[1]  Hugo Sax,et al.  Evidence-based model for hand transmission during patient care and the role of improved practices. , 2006, The Lancet. Infectious diseases.

[2]  Mark R Prausnitz,et al.  Microneedles permit transdermal delivery of a skin-impermeant medication to humans , 2008, Proceedings of the National Academy of Sciences.

[3]  Mahmoud Ameri,et al.  Transdermal delivery of desmopressin using a coated microneedle array patch system. , 2004, Journal of controlled release : official journal of the Controlled Release Society.

[4]  Petras Juzenas,et al.  Microneedle Arrays Permit Enhanced Intradermal Delivery of a Preformed Photosensitizer , 2009, Photochemistry and photobiology.

[5]  Melissa Ai Ling Teo,et al.  In Vitro and In Vivo Characterization of MEMS Microneedles , 2005, Biomedical microdevices.

[6]  Y. Kalia,et al.  Supersaturation: Enhancement of Skin Penetration and Permeation of a Lipophilic Drug , 2001, Pharmaceutical Research.

[7]  P. van Damme,et al.  Safety and efficacy of a novel microneedle device for dose sparing intradermal influenza vaccination in healthy adults. , 2009, Vaccine.

[8]  P. Elsner Antimicrobials and the skin physiological and pathological flora. , 2006, Current problems in dermatology.

[9]  Jung-Hwan Park,et al.  Biodegradable polymer microneedles: fabrication, mechanics and transdermal drug delivery , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  Vincent J. Sullivan,et al.  Microneedle-Based Intradermal Delivery of the Anthrax Recombinant Protective Antigen Vaccine , 2006, Infection and Immunity.

[11]  A. Morrissey,et al.  Clinical administration of microneedles: skin puncture, pain and sensation , 2009, Biomedical microdevices.

[12]  G. Rich Is isopropyl alcohol swabbing before injection really necessary? , 2001, The Medical journal of Australia.

[13]  Petras Juzenas,et al.  Microneedle-mediated intradermal delivery of 5-aminolevulinic acid: potential for enhanced topical photodynamic therapy. , 2008, Journal of controlled release : official journal of the Controlled Release Society.

[14]  A. Fourtanier,et al.  MINIATURE PIG AS AN ANIMAL MODEL TO STUDY PHOTOAGING * , 1988, Photochemistry and photobiology.

[15]  N. Harvey,et al.  Preclinical Evaluation of Microneedle Technology for Intradermal Delivery of Influenza Vaccines , 2007, Clinical and Vaccine Immunology.

[16]  A. Ludwig,et al.  Microneedles for transdermal drug delivery: a minireview. , 2008, Frontiers in bioscience : a journal and virtual library.

[17]  Mark R Prausnitz,et al.  Precise microinjection into skin using hollow microneedles. , 2006, The Journal of investigative dermatology.

[18]  Henry,et al.  Microfabricated microneedles: A novel approach to transdermal drug delivery , 1999, Journal of pharmaceutical sciences.

[19]  M. Cormier,et al.  Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system. , 2006, Vaccine.

[20]  J. Hadgraft,et al.  Supersaturated solutions evaluated with an in vitro stratum corneum tape stripping technique , 1997 .

[21]  E. McAdams,et al.  Moisture‐activated, electrically conducting bioadhesive hydrogels as interfaces for bioelectrodes: Effect of film hydration on cutaneous adherence in wet environments , 1995 .

[22]  Sion A. Coulman,et al.  Minimally invasive cutaneous delivery of macromolecules and plasmid DNA via microneedles. , 2006, Current drug delivery.

[23]  Mark G. Allen,et al.  Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies , 2003, Proceedings of the National Academy of Sciences of the United States of America.