In vivo imaging of neuronal calcium during electrode implantation: Spatial and temporal mapping of damage and recovery.

Implantable electrode devices enable long-term electrophysiological recordings for brain-machine interfaces and basic neuroscience research. Implantation of these devices, however, leads to neuronal damage and progressive neural degeneration that can lead to device failure. The present study uses in vivo two-photon microscopy to study the calcium activity and morphology of neurons before, during, and one month after electrode implantation to determine how implantation trauma injures neurons. We show that implantation leads to prolonged, elevated calcium levels in neurons within 150 μm of the electrode interface. These neurons show signs of mechanical distortion and mechanoporation after implantation, suggesting that calcium influx is related to mechanical trauma. Further, calcium-laden neurites develop signs of axonal injury at 1-3 h post-insert. Over the first month after implantation, physiological neuronal calcium activity increases, suggesting that neurons may be recovering. By defining the mechanisms of neuron damage after electrode implantation, our results suggest new directions for therapies to improve electrode longevity.

[1]  Andrew W. Kraft,et al.  Functional connectivity structure of cortical calcium dynamics in anesthetized and awake mice , 2017, PloS one.

[2]  J. Donoghue,et al.  Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates , 2013, Journal of neural engineering.

[3]  D. Kipke,et al.  Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[4]  R. Rajan,et al.  Traumatic Brain Injury and Neuronal Functionality Changes in Sensory Cortex , 2016, Front. Syst. Neurosci..

[5]  X Tracy Cui,et al.  Ultrasoft microwire neural electrodes improve chronic tissue integration. , 2017, Acta biomaterialia.

[6]  Ifije E. Ohiorhenuan,et al.  Cortical spreading depolarization: Pathophysiology, implications, and future directions , 2016, Journal of Clinical Neuroscience.

[7]  Seong-Gi Kim,et al.  In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes , 2012, Journal of neural engineering.

[8]  A. Sinning,et al.  Minireview: pH and synaptic transmission , 2013, FEBS letters.

[9]  Deborah S. Barkauskas,et al.  The roles of blood-derived macrophages and resident microglia in the neuroinflammatory response to implanted intracortical microelectrodes. , 2014, Biomaterials.

[10]  Xiliang Luo,et al.  Carbon nanotube nanoreservior for controlled release of anti-inflammatory dexamethasone. , 2011, Biomaterials.

[11]  Arati Sridharan,et al.  Long-term changes in the material properties of brain tissue at the implant–tissue interface , 2013, Journal of neural engineering.

[12]  X Tracy Cui,et al.  Dexamethasone retrodialysis attenuates microglial response to implanted probes in vivo. , 2016, Biomaterials.

[13]  Victoria E. Johnson,et al.  Partial interruption of axonal transport due to microtubule breakage accounts for the formation of periodic varicosities after traumatic axonal injury , 2012, Experimental Neurology.

[14]  A. Taylor-Weiner,et al.  Traumatic Brain Injury Increases Cortical Glutamate Network Activity by Compromising GABAergic Control. , 2015, Cerebral cortex.

[15]  Brenda C. Shields,et al.  Thy1-GCaMP6 Transgenic Mice for Neuronal Population Imaging In Vivo , 2014, PloS one.

[16]  Sreekanth H. Chalasani,et al.  Imaging neural activity in worms, flies and mice with improved GCaMP calcium indicators , 2009, Nature Methods.

[17]  Edwin B. Yan,et al.  Sensory Cortex Underpinnings of Traumatic Brain Injury Deficits , 2012, PloS one.

[18]  J. Povlishock,et al.  A mechanistic analysis of nondisruptive axonal injury: a review. , 1997, Journal of neurotrauma.

[19]  Carl F. Lagenaur,et al.  The surface immobilization of the neural adhesion molecule L1 on neural probes and its effect on neuronal density and gliosis at the probe/tissue interface. , 2011, Biomaterials.

[20]  Kimberle M. Jacobs,et al.  Electrophysiological Abnormalities in Both Axotomized and Nonaxotomized Pyramidal Neurons following Mild Traumatic Brain Injury , 2012, The Journal of Neuroscience.

[21]  Kip A Ludwig,et al.  Tissue damage thresholds during therapeutic electrical stimulation , 2016, Journal of neural engineering.

[22]  Douglas H. Smith,et al.  Axonal pathology in traumatic brain injury , 2013, Experimental Neurology.

[23]  Huanan Zhang,et al.  Nanostructured Coatings for Improved Charge Delivery to Neurons , 2014 .

[24]  G. Feng,et al.  Imaging Neuronal Subsets in Transgenic Mice Expressing Multiple Spectral Variants of GFP , 2000, Neuron.

[25]  Michelle C LaPlaca,et al.  Mechanical trauma induces immediate changes in neuronal network activity , 2005, Journal of neural engineering.

[26]  Alberto L Vazquez,et al.  Multi-scale, multi-modal analysis uncovers complex relationship at the brain tissue-implant neural interface: new emphasis on the biological interface , 2018, Journal of neural engineering.

[27]  Alan P. Koretsky,et al.  TRANSCRANIAL AMELIORATION OF INFLAMMATION AND CELL DEATH FOLLOWING BRAIN INJURY , 2013, Nature.

[28]  O. B. Ozdoganlar,et al.  Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes. , 2014, Biomaterials.

[29]  Andrew B. Schwartz,et al.  Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics , 2006, Neuron.

[30]  Paul R. Carney,et al.  In vivo evaluation of needle force and friction stress during insertion at varying insertion speed into the brain , 2014, Journal of Neuroscience Methods.

[31]  David C. Martin,et al.  Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays , 2005, Experimental Neurology.

[32]  Benjamin R. Arenkiel,et al.  Imaging Neural Activity Using Thy1-GCaMP Transgenic Mice , 2012, Neuron.

[33]  M. Moskowitz,et al.  Acute Plasmalemma Permeability and Protracted Clearance of Injured Cells after Controlled Cortical Impact in Mice , 2008, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[34]  R. Normann,et al.  Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex , 1998, Journal of Neuroscience Methods.

[35]  David F. Meaney,et al.  Dynamic Changes in Neural Circuit Topology Following Mild Mechanical Injury In Vitro , 2011, Annals of Biomedical Engineering.

[36]  P. Uhlén Spectral Analysis of Calcium Oscillations , 2004, Science's STKE.

[37]  J Miller,et al.  Minocycline increases quality and longevity of chronic neural recordings , 2007, Journal of neural engineering.

[38]  Daryl R. Kipke,et al.  Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes , 2006, IEEE Transactions on Biomedical Engineering.

[39]  Euisik Yoon,et al.  Chronic In Vivo Evaluation of PEDOT/CNT for Stable Neural Recordings , 2016, IEEE Transactions on Biomedical Engineering.

[40]  Takashi D Y Kozai,et al.  Photoelectric artefact from optogenetics and imaging on microelectrodes and bioelectronics: New Challenges and Opportunities. , 2015, Journal of materials chemistry. B.

[41]  Takashi D. Y. Kozai,et al.  Glial responses to implanted electrodes in the brain , 2017, Nature Biomedical Engineering.

[42]  Seong-Gi Kim,et al.  Optogenetic investigation of the variable neurovascular coupling along the interhemispheric circuits , 2018, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[43]  X. Cui,et al.  Electrically Controlled Drug Delivery from Graphene Oxide Nanocomposite Films , 2014, ACS nano.

[44]  Zhanhong Du,et al.  Comprehensive chronic laminar single-unit, multi-unit, and local field potential recording performance with planar single shank electrode arrays , 2015, Journal of Neuroscience Methods.

[45]  Stuart F Cogan,et al.  Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation , 2004, Journal of Neuroscience Methods.

[46]  Erdrin Azemi,et al.  Seeding neural progenitor cells on silicon-based neural probes. , 2010, Journal of neurosurgery.

[47]  Christian Franck,et al.  Strain and rate-dependent neuronal injury in a 3D in vitro compression model of traumatic brain injury , 2016, Scientific Reports.

[48]  Ssang-Goo Cho,et al.  Direct visualization of membrane architecture of myelinating cells in transgenic mice expressing membrane‐anchored EGFP , 2014, Genesis.

[49]  James R Eles,et al.  Unique electrophysiological and impedance signatures between encapsulation types: An analysis of biological Utah array failure and benefit of a biomimetic coating in a rat model. , 2018, Biomaterials.

[50]  Ravi V. Bellamkonda,et al.  Controlled release of anti-inflammatory agent alpha-MSH from neural implants. , 2005, Journal of controlled release : official journal of the Controlled Release Society.

[51]  J. Wolf,et al.  Traumatic Axonal Injury Induces Calcium Influx Modulated by Tetrodotoxin-Sensitive Sodium Channels , 2001, The Journal of Neuroscience.

[52]  Douglas H. Smith,et al.  Mechanical breaking of microtubules in axons during dynamic stretch injury underlies delayed elasticity, microtubule disassembly, and axon degeneration , 2010, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[53]  Huanan Zhang,et al.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings , 2015, Journal of neural engineering.

[54]  Paras R. Patel,et al.  Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces. , 2012, Nature materials.

[55]  Takashi D Y Kozai,et al.  In vivo spatiotemporal dynamics of NG2 glia activity caused by neural electrode implantation. , 2018, Biomaterials.

[56]  Jeffrey R Capadona,et al.  The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes. , 2013, Biomaterials.

[57]  Karen L. Smith,et al.  Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion , 2006, Journal of neural engineering.

[58]  R. Shi Polyethylene glycol repairs membrane damage and enhances functional recovery: a tissue engineering approach to spinal cord injury , 2013, Neuroscience Bulletin.

[59]  G. Reiser,et al.  Calcium dysregulation and homeostasis of neural calcium in the molecular mechanisms of neurodegenerative diseases provide multiple targets for neuroprotection. , 2011, Antioxidants & redox signaling.

[60]  Daryl R Kipke,et al.  Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities , 2008, The Journal of Neuroscience.

[61]  Seong-Gi Kim,et al.  Neural and Hemodynamic Responses to Optogenetic and Sensory Stimulation in the Rat Somatosensory Cortex , 2015, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[62]  Robert K. Shepherd,et al.  Stimulus Induced pH Changes in Cochlear Implants: An In Vitro and In Vivo Study , 2001, Annals of Biomedical Engineering.

[63]  D R Kipke,et al.  Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping , 2010, Journal of neural engineering.

[64]  Leigh R. Hochberg,et al.  Review: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces , 2017, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[65]  Nicholas J Michelson,et al.  A Materials Roadmap to Functional Neural Interface Design , 2018, Advanced functional materials.

[66]  R. Borgens,et al.  INTRAVENOUS POLYETHYLENE GLYCOL SUCCESSFULLY TREATS SEVERE ACCELERATION‐INDUCED BRAIN INJURY IN RATS AS ASSESSED BY MAGNETIC RESONANCE IMAGING , 2009, Neurosurgery.

[67]  A. Michael,et al.  Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies , 2014, ACS chemical neuroscience.

[68]  Rosalind Pratt,et al.  Direct, Live Imaging of Cortical Spreading Depression and Anoxic Depolarisation Using a Fluorescent, Voltage-Sensitive Dye , 2008, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[69]  G. Buzsáki Large-scale recording of neuronal ensembles , 2004, Nature Neuroscience.

[70]  N. Weisleder,et al.  Poloxamer 188 (p188) as a membrane resealing reagent in biomedical applications. , 2012, Recent patents on biotechnology.

[71]  E K Purcell,et al.  In vivo evaluation of a neural stem cell-seeded prosthesis , 2009, Journal of neural engineering.

[72]  Kelsey A. Potter,et al.  Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses , 2012, Journal of neural engineering.

[73]  Daniel R. Merrill,et al.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols , 2005, Journal of Neuroscience Methods.

[74]  V. De Paola,et al.  Synaptic Elimination and Protection after Minimal Injury Depend on Cell Type and Their Prelesion Structural Dynamics in the Adult Cerebral Cortex , 2013, The Journal of Neuroscience.

[75]  David F Meaney,et al.  Single-Neuron NMDA Receptor Phenotype Influences Neuronal Rewiring and Reintegration following Traumatic Injury , 2014, The Journal of Neuroscience.

[76]  Michelle C LaPlaca,et al.  Mechanical stretch to neurons results in a strain rate and magnitude-dependent increase in plasma membrane permeability. , 2003, Journal of neurotrauma.

[77]  J. Lifshitz,et al.  Diffuse traumatic brain injury initially attenuates and later expands activation of the rat somatosensory whisker circuit concomitant with neuroplastic responses , 2010, Brain Research.

[78]  Xinyan Tracy Cui,et al.  Electrochemically controlled release of dexamethasone from conducting polymer polypyrrole coated electrode. , 2006, Journal of controlled release : official journal of the Controlled Release Society.

[79]  A. Vazquez,et al.  Two-photon imaging of chronically implanted neural electrodes: Sealing methods and new insights , 2016, Journal of Neuroscience Methods.

[80]  Erin K Purcell,et al.  Functional remodeling of subtype-specific markers surrounding implanted neuroprostheses. , 2017, Journal of neurophysiology.

[81]  W Eberle,et al.  A response surface model predicting the in vivo insertion behavior of micromachined neural implants , 2012, Journal of neural engineering.

[82]  J. Csicsvari,et al.  Intracellular features predicted by extracellular recordings in the hippocampus in vivo. , 2000, Journal of neurophysiology.

[83]  Vikash Gilja,et al.  Long-term Stability of Neural Prosthetic Control Signals from Silicon Cortical Arrays in Rhesus Macaque Motor Cortex , 2010 .

[84]  Nicholas P. Szrama,et al.  Histological evaluation of a chronically-implanted electrocorticographic electrode grid in a non-human primate , 2016, Journal of neural engineering.

[85]  A. Levey,et al.  Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration , 2009, Journal of neural engineering.

[86]  C. Koch,et al.  The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes , 2012, Nature Reviews Neuroscience.

[87]  Jordi Soriano,et al.  Identification of neuronal network properties from the spectral analysis of calcium imaging signals in neuronal cultures , 2013, Front. Neural Circuits.

[88]  Andrew B Schwartz,et al.  Cortical neural prosthetics. , 2004, Annual review of neuroscience.

[89]  L. Carin,et al.  Relationship between intracortical electrode design and chronic recording function. , 2013, Biomaterials.

[90]  Carl Lagenaur,et al.  Neuroadhesive L1 coating attenuates acute microglial attachment to neural electrodes as revealed by live two-photon microscopy. , 2017, Biomaterials.

[91]  T. W. Ridler,et al.  Picture thresholding using an iterative selection method. , 1978 .

[92]  Takashi D Y Kozai,et al.  Understanding the Inflammatory Tissue Reaction to Brain Implants To Improve Neurochemical Sensing Performance. , 2017, ACS chemical neuroscience.

[93]  O. Griesbeck,et al.  A recoverable state of axon injury persists for hours after spinal cord contusion in vivo , 2014, Nature Communications.

[94]  D J Weber,et al.  In vivo effects of L1 coating on inflammation and neuronal health at the electrode-tissue interface in rat spinal cord and dorsal root ganglion. , 2012, Acta biomaterialia.

[95]  X Tracy Cui,et al.  Effects of caspase-1 knockout on chronic neural recording quality and longevity: insight into cellular and molecular mechanisms of the reactive tissue response. , 2014, Biomaterials.

[96]  Huanan Zhang,et al.  Chronic in vivo stability assessment of carbon fiber microelectrode arrays , 2016, Journal of neural engineering.