Miniaturised multiplexed immunoassays.

Miniaturised immunoassays are of general interest for applications that require the simultaneous determination of different parameters from a minute sample of material. Apart from planar microarray-based systems, bead-based flow cytometric approaches are well suited for the multiplexed detection of target molecules, especially when the number of parameters that have to be determined in parallel is limited.

[1]  R. Ekins,et al.  Ligand assays: from electrophoresis to miniaturized microarrays. , 1998, Clinical chemistry.

[2]  R Bellisario,et al.  Simultaneous measurement of antibodies to three HIV-1 antigens in newborn dried blood-spot specimens using a multiplexed microsphere-based immunoassay. , 2001, Early human development.

[3]  R. Maiolini,et al.  A sandwich method of enzymoimmunoassay. I. Application to rat and human alpha-fetoprotein. , 1975, Journal of immunological methods.

[4]  L A Herzenberg,et al.  Monoclonal antibodies and the FACS: complementary tools for immunobiology and medicine. , 2000, Immunology today.

[5]  M. Hogan,et al.  Simultaneous multianalyte ELISA performed on a microarray platform. , 2001, Clinical chemistry.

[6]  Dieter Stoll,et al.  A microarray enzyme‐linked immunosorbent assay for autoimmune diagnostics , 2000, Electrophoresis.

[7]  Frances S. Ligler,et al.  An Array Immunosensor for Simultaneous Detection of Clinical Analytes , 1999 .

[8]  Ruo-Pan Huang,et al.  Simultaneous Detection of Multiple Proteins with an Array-Based Enzyme-Linked Immunosorbent Assay (ELISA) and Enhanced Chemiluminescence (ECL) , 2001, Clinical chemistry and laboratory medicine.

[9]  D. Dufour,et al.  Enzyme-linked immunoassay for alpha-fetoprotein by competitive and sandwich procedures. , 1973, Clinica chimica acta; international journal of clinical chemistry.

[10]  D. Housman,et al.  Human single-chain Fv intrabodies counteract in situ huntingtin aggregation in cellular models of Huntington's disease , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[11]  L. G. Mendoza,et al.  High-throughput microarray-based enzyme-linked immunosorbent assay (ELISA). , 1999, BioTechniques.

[12]  S. Weinberger,et al.  Recent trends in protein biochip technology. , 2000, Pharmacogenomics.

[13]  A. Mirzabekov,et al.  Protein microchips: use for immunoassay and enzymatic reactions. , 2000, Analytical biochemistry.

[14]  Chris A. Rowe-Taitt,et al.  Simultaneous detection of six biohazardous agents using a planar waveguide array biosensor. , 2000, Biosensors & bioelectronics.

[15]  S. Kingsmore,et al.  Immunoassays with rolling circle DNA amplification: a versatile platform for ultrasensitive antigen detection. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[16]  R Ekins,et al.  Multispot, multianalyte, immunoassay. , 1990, Annales de biologie clinique.

[17]  D. Ryu,et al.  Recent Progress in Biomolecular Engineering , 2000, Biotechnology progress.

[18]  Ekins Rp,et al.  The estimation of thyroxine in human plasma by an electrophoretic technique , 1960 .

[19]  Anthony D. Keefe,et al.  The use of mRNA display to select high-affinity protein-binding peptides , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[20]  Uwe Pieles,et al.  Novel bioaffinity sensors for trace analysis based on luminescence excitation by planar waveguides , 1997 .

[21]  D. Vignali,et al.  Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. , 1999, Journal of immunological methods.

[22]  A. Plückthun,et al.  Fully synthetic human combinatorial antibody libraries (HuCAL) based on modular consensus frameworks and CDRs randomized with trinucleotides. , 2000, Journal of molecular biology.

[23]  R J Fulton,et al.  Advanced multiplexed analysis with the FlowMetrix system. , 1997, Clinical chemistry.

[24]  Chen,et al.  Simultaneous Quantification of Six Human Cytokines in a Single Sample Using Microparticle-based Flow Cytometric Technology. , 1999, Clinical chemistry.

[25]  John W. Silzel,et al.  Mass-sensing, multianalyte microarray immunoassay with imaging detection. , 1998, Clinical chemistry.

[26]  S A BERSON,et al.  Immunoassay of endogenous plasma insulin in man. , 1996, The Journal of clinical investigation.

[27]  R. Lerner,et al.  Making artificial antibodies: a format for phage display of combinatorial heterodimeric arrays. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[28]  C. Milstein,et al.  Continuous cultures of fused cells secreting antibody of predefined specificity , 1975, Nature.

[29]  D Gianola,et al.  Multicenter validation of recombinant, natural and synthetic antigens used in a single multiparameter assay for the detection of specific anti-nuclear autoantibodies in connective tissue disorders. , 1999, Clinical and experimental rheumatology.

[30]  R. Ekins,et al.  Multi-analyte immunoassay. , 1989, Journal of pharmaceutical and biomedical analysis.