Design and compatibility of a high-performance actuation system for fMRI-based neuroscience studies

Haptic interfaces compatible with functional magnetic resonance imaging (fMRI) are finding increasing interest as a tool to explore the neural correlates of human motor control and related dysfunctions. To achieve safety and MR compatibility, such devices have mainly relied on unconventional actuation methods suffering from limited bandwidth and non-linearities. This has resulted in complex control and restricted their use in applications involving fine and dynamic interaction with the hand and fingers. To address these limitations, we propose a concept for a shielded high-performance actuation system to be located inside the MR room, evaluate the effectiveness of the shielding and perform detailed MR compatibility tests. A conventional electromagnetic actuator is located within a steel shield to prevent mutual disturbance with magnetic fields of the scanner, which, together with power and control hardware, is placed within a Faraday cage with only a fiber-optical USB link to the control room. Detailed compatibility tests show that disturbing dynamic electromagnetic fields generated by the actuation system are well below the detectable threshold of the scanner, and actuator performance is not degraded by the MR environment. In combination with a light and stiff cable or rod transmission, the presented actuator technology, providing high transparency and force bandwidth, paves the way for fMRI-based neuroscience studies, e.g., to investigate the fine motor control of hand and fingers.

[1]  Akio Yamamoto,et al.  Actuation Methods for Applications in MR Environments , 2006 .

[2]  B. Schueler,et al.  MRI compatibility and visibility assessment of implantable medical devices , 1999, Journal of magnetic resonance imaging : JMRI.

[3]  Ieee Antennas,et al.  Electromagnetics: History, Theory, and Applications , 1993 .

[4]  Toshiyuki Kondo,et al.  MR compatible manipulandum with ultrasonic motor for fMRI studies , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[5]  Richard S. J. Frackowiak,et al.  Motor system activation after subcortical stroke depends on corticospinal system integrity. , 2006, Brain : a journal of neurology.

[6]  Marko Munih,et al.  Upper limb motion analysis using haptic interface , 2001 .

[7]  E. Burdet,et al.  Opportunities and Challenges in MR-Compatible Robotics , 2008, IEEE Engineering in Medicine and Biology Magazine.

[8]  G. Rizzolatti,et al.  Action observation activates premotor and parietal areas in a somatotopic manner: an fMRI study , 2001, The European journal of neuroscience.

[9]  R. Gassert,et al.  MRI/fMRI-compatible robotic system with force feedback for interaction with human motion , 2006, IEEE/ASME Transactions on Mechatronics.

[10]  G. Glover,et al.  Correction of physiologically induced global off‐resonance effects in dynamic echo‐planar and spiral functional imaging , 2002, Magnetic resonance in medicine.

[11]  R. Riener,et al.  An fMRI compatible haptic interface with pneumatic actuation , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[12]  Etienne Burdet,et al.  A hybrid ultrasonic motor and electrorheological fluid clutch actuator for force-feedback in MRI/fMRI , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  Antonio Frisoli,et al.  Design of a new fMRI compatible haptic interface , 2009, World Haptics 2009 - Third Joint EuroHaptics conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems.

[14]  Etienne Burdet,et al.  A 2-DOF fMRI compatible haptic interface to investigate the neural control of arm movements , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[15]  Marko Munih,et al.  Phantom haptic device upgrade for use in fMRI , 2009, Medical & Biological Engineering & Computing.

[16]  Olivier Lambercy,et al.  ReGrasp, a robotic tool to investigate fine motor control and track therapy-induced neuroplasticity , 2010, 2010 IEEE International Conference on Robotics and Automation.

[17]  H. Imamizu,et al.  Evaluation of MR-compatibility of Electrostatic Linear Motor , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[18]  Akio Yamamoto,et al.  Development of a 2-DOF electrostatic haptic joystick for MRI/fMRI applications , 2009, 2009 IEEE International Conference on Robotics and Automation.

[19]  Mark E. Ladd,et al.  Design of an MR‐compatible piezoelectric actuator for MR elastography , 2002 .

[20]  D. Heeger,et al.  In this issue , 2002, Nature Reviews Drug Discovery.