Coronary angiography using laser plasma sources: X-ray source efficiency and optimization of a bent crystal monochromator

A monochromator has been developed for coronary angiography, comprising a single bent crystal of silicon in Laue transmission geometry. K spectra of laser irradiated solid tin and tantalum (Z=50 and 73, respectively) targets were measured. The high resolution crystal spectrometer resolve the Sn and Ta Kα doublets, allowing in a proof-of-principle experiment the absolute Kα photon numbers emitted by the source to be determined. The Ta Kα yield is measured as a function of the laser pulse energy, allowing an assessment to be made of the suitability of such sources for medical applications.

[1]  O. Wehrhan,et al.  Characterization of Flat and Bent Crystals for X‐ray Spectroscopy and Imaging , 1998 .

[2]  R. Kahn,et al.  X-ray curved-crystal monochromator system at the storage ring DCI , 1978 .

[3]  A. H. Compton,et al.  X-rays in Theory and Experiment , 1935 .

[4]  Antonio Pifferi,et al.  Time-gated imaging in radiology: theoretical and experimental studies , 1996 .

[5]  P M Bell,et al.  Time-gated imaging with an ultrashort-pulse, laser-produced-plasma x-ray source. , 1995, Optics letters.

[6]  William Thomlinson,et al.  Performance evaluation of a bent Laue monochromator , 1990 .

[7]  G Svahn,et al.  Generation of x rays for medical imaging by high-power lasers: preliminary results. , 1993, Radiology.

[8]  Forster,et al.  Yield optimization and time structure of femtosecond laser plasma kalpha sources , 2000, Physical review letters.

[9]  D. Siddons,et al.  A single crystal bent Laue monochromator for coronary angiography , 1993 .

[10]  S. Svanberg,et al.  X-Ray Crystal Spectroscopy of Sub-picosecond Laser-Produced Plasmas beyond 50 keV , 1997 .

[11]  Sune Svanberg,et al.  Elemental biological imaging by differential absorption with a laser-produced x-ray source , 1996 .

[12]  W.-R. Dix,et al.  Double beam bent Laue monochromator for coronary angiography , 1995 .

[13]  Z. G. Pinsker Dynamical Scattering of X-Rays in Crystals , 1978 .

[14]  P Suortti,et al.  Fixed-exit monochromators for high-energy synchrotron radiation. , 1995, Journal of synchrotron radiation.

[15]  Antoine Rousse,et al.  Experimental study of the interaction of subpicosecond laser pulses with solid targets of varying initial scale lengths , 1997 .

[16]  D. Chapman,et al.  PEPO : A PROGRAM FOR THE CALCULATION OF THE REFLECTIVITY OF CYLINDRICALLY BENT LAUE CRYSTAL MONOCHROMATORS , 1995 .