A screen-printed, amperometric biosensor array incorporated into a novel automated system for the simultaneous determination of organophosphate pesticides.

Organophosphate pesticides present serious risks to human and environmental health. A rapid reliable, economical and portable analytical system will be of great benefit in the detection and prevention of contamination. A biosensor array based on six acetylcholinesterase enzymes for use in a novel automated instrument incorporating a neural network program is described. Electrochemical analysis was carried out using chronoamperometry and the measurement was taken 10s after applying a potential of 0 V vs. Ag/AgCl. The total analysis time for the complete assay was less than 6 min. The array was used to produce calibration data with six organophosphate pesticides (OPs) in the concentration range of 10(-5) M to 10(-9) M to train a neural network. The output of the neural network was subsequently evaluated using different sample matrices. There were no detrimental matrix effects observed from water, phosphate buffer, food or vegetable extracts. Furthermore, the sensor system was not detrimentally affected by the contents of water samples taken from each stage of the water treatment process. The biosensor system successfully identified and quantified all samples where an OP was present in water, food and vegetable extracts containing different OPs. There were no false positives or false negatives observed during the evaluation of the analytical system. The biosensor arrays and automated instrument were evaluated in situ in field experiments where the instrument was successfully applied to the analysis of a range of environmental samples. It is envisaged that the analytical system could provide a rapid detection system for the early warning of contamination in water and food.

[1]  Damià Barceló,et al.  Biosensors as useful tools for environmental analysis and monitoring , 2006, Analytical and bioanalytical chemistry.

[2]  R. Kamanyire,et al.  Organophosphate toxicity and occupational exposure. , 2004, Occupational medicine.

[3]  Jean-Louis Marty,et al.  Twenty years research in cholinesterase biosensors: from basic research to practical applications. , 2006, Biomolecular engineering.

[4]  J. Hoppin,et al.  Health effects of chronic pesticide exposure: cancer and neurotoxicity. , 2004, Annual review of public health.

[5]  F. Díaz-Fierros,et al.  Measurement of cholinesterase activity inhibition for the detection of organophosphorus and carbamate pesticides in water , 1995 .

[6]  J. Marty,et al.  Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks. , 2000, Biosensors & bioelectronics.

[7]  Kushik Jaga,et al.  Sources of exposure to and public health implications of organophosphate pesticides. , 2003, Revista panamericana de salud publica = Pan American journal of public health.

[8]  A Mulchandani,et al.  Amperometric microbial biosensor for direct determination of organophosphate pesticides using recombinant microorganism with surface expressed organophosphorus hydrolase. , 2001, Biosensors & bioelectronics.

[9]  John P. Hart,et al.  Voltammetric and amperometric studies of thiocholine at a screen-printed carbon electrode chemically modified with cobalt phthalocyanine: studies towards a pesticide sensor , 1994 .

[10]  John P. Hart,et al.  Amperometric measurement of organophosphate pesticides using a screen-printed disposable sensor and biosensor based on cobalt phthalocyanine , 1994 .

[11]  Ashok Mulchandani,et al.  Recent biosensing developments in environmental security. , 2008, Journal of environmental monitoring : JEM.

[12]  Till T Bachmann,et al.  Design of acetylcholinesterases for biosensor applications. , 2003, Biosensors & bioelectronics.

[13]  K. Courtney,et al.  A new and rapid colorimetric determination of acetylcholinesterase activity. , 1961, Biochemical pharmacology.

[14]  John P. Hart,et al.  Some Recent Designs and Developments of Screen‐Printed Carbon Electrochemical Sensors/Biosensors for Biomedical, Environmental, and Industrial Analyses , 2004 .

[15]  Brian J. Birch,et al.  Development of screen-printed carbon electrodes, chemically modified with cobalt phthalocyanine, for electrochemical sensor applications , 1990 .

[16]  J. Marty,et al.  Amperometric biosensors based on nafion coated screen-printed electrodes for the determination of cholinesterase inhibitors. , 2000, Talanta.

[17]  Jean-Louis Marty,et al.  A Screen‐Printed, Amperometric, Biosensor Array for the Detection of Organophosphate Pesticides Based on Inhibition of Wild Type, and Mutant Acetylcholinesterases, from Drosophila melanogaster , 2004 .